Immersion & wet locations
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Product
RG7OEFE 0.6/1 kV (MARINE) Class 2 Tinned-Copper G7 HEPR-Insulated Galvanized Steel-Wire & Spiral Steel-Tape Armoured (200m / 20 bar) Seabed Underwater Power Cable (CEI 20-13 / IEC 60502-1, 0.6/1 kV, -25 °C to +90 °C).
Typical values for this cable type, based on CEI 20-13 / IEC 60502-1 / 20 bar (200 m) Seabed Power — confirmed in the datasheet and quotation for your order.
Application fit
RG7OEFE 0.6/1 kV (MARINE) Class 2 Tinned-Copper G7 HEPR-Insulated Galvanized Steel-Wire & Spiral Steel-Tape Armoured (200m / 20 bar) Seabed Underwater Power Cable (CEI 20-13 / IEC 60502-1, 0.6/1 kV, -25 °C to +90 °C).
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Marine-grade jacket resists oil, seawater, UV weathering and mechanical impact on vessels and offshore structures.
Approved for fixed shipboard, submarine outboard, nuclear pool and seabed feeder routing.
Flexible stranded copper conductors terminate cleanly into submersible pumps, anodes, thrusters and switchgear.
Outboard marine and feeder construction is not designed for high-speed crane festoon trolleys.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: RG7OEFE 0.6/1 KV (MARINE) (CEI 20-13 / IEC 60502-1 / 20 bar (200 m) Seabed Power) featuring phase conductors (class 2 tinned copper), g7 quality hepr insulation (0.6/1 kv) and black uv-resistant pe outer sheath (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Phase Conductors (Class 2 Tinned Copper) | IEC 60228 Class 2 stranded tinned copper conductors (3G1.5–50 & 4G1.5–50 mm²) |
| 2 | G7 Quality HEPR Insulation (0.6/1 kV) | High-modulus cross-linked ethylene propylene rubber (CEI 20-13, 90 °C / 250 °C SC) |
| 3 | Extruded Polyethylene Inner Sheath | Continuous PE inner bedding sheath protecting cores against 20 bar water pressure |
| 4 | Composite Steel Wire + Spiral Steel Tape (FE) | 1° helically served galvanized steel wires + 2° spiral galvanized steel binder tape |
| 5 | Black UV-Resistant PE Outer Sheath | Extruded black polyethylene outer jacket for 200 m (20 bar) seabed installation |
Built to CEI 20-13 / IEC 60502-1 / 20 bar (200 m) Seabed Power with phase conductors (class 2 tinned copper) and black uv-resistant pe outer sheath
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to CEI 20-13 / IEC 60502-1 / 20 bar (200 m) Seabed Power for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| RG7OEFE 0.6/1 KV (MARINE) Construction Schedule (−25…+90 °C) | |||||||
| RG7OEFE 0.6 4G16 mm² | 4G16 mm² (3×16 + 1G16) | IEC 60228 Class 5 flexible Cu/SnCu | 21.8 | 840 | 2.4 | 130 | |
| RG7OEFE 0.6 4G35 mm² | 4G35 mm² (3×35 + 1G16) | IEC 60228 Class 5 flexible Cu/SnCu | 28.6 | 1,620 | 5.2 | 172 | |
| RG7OEFE 0.6 3×70 + 3G16 mm² | 3 × 70 mm² + 3G16 mm² | IEC 60228 Class 5 flexible Cu/SnCu | 38.4 | 3,180 | 10.5 | 230 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4G16 mm² (3×16 + 1G16) | 1.21 | 0.6/1 kV (94 A submerged) | −25…+90 °C |
| 4G35 mm² (3×35 + 1G16) | 0.55 | 0.6/1 kV (152 A submerged) | −25…+90 °C |
| 3 × 70 mm² + 3G16 mm² | 0.27 | 0.6/1 kV (235 A submerged) | −25…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (CEI 20-13 / IEC 60502-1 / 20 bar (200 m) Seabed Power) | DC resistance at 20 °C / optical attenuation and outer diameter within CEI 20-13 / IEC 60502-1 / 20 bar (200 m) Seabed Power tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (CEI 20-13 / IEC 60502-1 / 20 bar (200 m) Seabed Power) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (CEI 20-13 / IEC 60502-1 / 20 bar (200 m) Seabed Power) | Verified submersion integrity, tensile load and thermal stability across −25…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.