Offshore platform & shipboard deck trays
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Product
LKMSM-MV 3.6/6–18/30 kV & LSM-HF IEC 60092-354 Marine & Icebreaker MV Propulsion Cable (IEC 60092-354) engineered for 3.6/6 kV – 18/30 kV service across -40 to +90 °C (min. bend radius 12 × OD).
Typical values for this cable type, based on IEC 60092-354 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A — confirmed in the datasheet and quotation for your order.
Application fit
LKMSM-MV 3.6/6–18/30 kV & LSM-HF IEC 60092-354 Marine & Icebreaker MV Propulsion Cable (IEC 60092-354) engineered for 3.6/6 kV – 18/30 kV service across -40 to +90 °C (min. bend radius 12 × OD).
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Approved for bulkheads, cable trays, ladders and hull penetrations on commercial vessels and offshore units.
Metallic braid armour and cross-linked EPR/XLPE/XLPO insulation handle heavy mechanical and thermal duty.
Stranded copper or tinned copper conductors terminate cleanly into marine switchboards, thrusters and transformers.
Armoured shipboard and offshore feeder cable is not designed for high-cycle automation drag chains.
Use Drag-Chain Servo CableConstruction
Shown: LKMSM-MV 3.6/6-18/30 KV & LSM-HF (IEC 60092-354 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A) featuring stranded copper conductor (1×240 mm²), triple-extruded xlpe mv insulation and red shf1 / shf2 marine mv jacket (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded Copper Conductor (1×240 mm²) | IEC 60228 Class 2 / Class 5 copper conductor for Pod Propulsion propulsion |
| 2 | Triple-Extruded XLPE MV Insulation | Dry-cured conductor screen + 8.7/15 kV XLPE + strippable insulation screen |
| 3 | Concentric Copper Wire & Tape Screen (SM | Helically applied copper wires + counter-helix copper equalizing tape |
| 4 | Non-Magnetic Copper Braid Armour (LK) | Braided copper wire armour over halogen-free inner sheath |
| 5 | Red SHF1 / SHF2 Marine MV Jacket | High-visibility red low-smoke zero-halogen outer sheath (IEC 60092-354) |
Built to IEC 60092-354 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A with stranded copper conductor (1×240 mm²) and red shf1 / shf2 marine mv jacket
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to IEC 60092-354 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| LKMSM-MV 3.6/6-18/30 KV & LSM-HF Construction Schedule (−40…+90 °C) | |||||||
| LKMSM-MV 3.6 3×50 mm² MV | 3 × 50 mm² | IEC 60228 Class 2/5 Cu/SnCu | 42.5 | 2,980 | 22.5 | 510 | |
| LKMSM-MV 3.6 3×95 mm² MV | 3 × 95 mm² | IEC 60228 Class 2/5 Cu/SnCu | 51.8 | 4,690 | 42.8 | 620 | |
| LKMSM-MV 3.6 3×150 mm² MV | 3 × 150 mm² | IEC 60228 Class 2/5 Cu/SnCu | 61.2 | 6,840 | 67.5 | 735 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 50 mm² | 0.39 | 3.6/6 kV – 18/30 kV (195 A) | −40…+90 °C |
| 3 × 95 mm² | 0.19 | 3.6/6 kV – 18/30 kV (285 A) | −40…+90 °C |
| 3 × 150 mm² | 0.12 | 3.6/6 kV – 18/30 kV (365 A) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEC 60092-354 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A) | DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60092-354 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEC 60092-354 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A) | Zero dielectric breakdown and verified insulation resistance for 3.6/6 kV – 18/30 kV rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (IEC 60092-354 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking