Mine roadway & tunnel wall hangers
Suspended on roadway J-hooks or laid along mine drift floors to feed auxiliary fans, dewatering pumps and drills.
Product
Heavy-duty French underground mining and tunnelling flexible power feeder (Type 1A) and multicore auxiliary control cable (Type 1B) built to Charbonnages de France SCGMS 19050 and NF M 82-375 with Class 5 tinned copper conductors, +90 °C EPR insulation.
Typical values for this cable type, based on Charbonnages de France SCGMS 19050 / NF M 82-375 / IEC 60245 — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for semi-fixed and mobile low-voltage power distribution (Type 1A: Pumps, ventilation fans, stage loaders, hydraulic power packs) and auxiliary remote control/signalling (Type 1B) in underground mines, potash/phosphate galleries and civil TBM tunnels across France, North/West Africa and Europe.
Suspended on roadway J-hooks or laid along mine drift floors to feed auxiliary fans, dewatering pumps and drills.
Double-sheathed EPR/PCP construction withstands rock abrasion, diesel exhaust oil mist and alkaline grout water on TBM back-up gantries.
Flexible Class 5 tinned copper cores accommodate frequent relocation as mining faces and tunnel headings advance.
Unscreened semi-mobile feeder; for high-speed dynamic reeling or gassy shearer faces requiring individual screens, specify screened Type.
YHKGXSFoyn Shaft Wire-Armoured CableConstruction
Shown: SCGMS 19050 Type 1A 4G50 mm² 0.6/1 kV with Class 5 flexible tinned copper conductors, +90 °C cross-linked EPR insulation, extruded elastomeric inner filler sheath and heavy-duty black Polychloroprene (PCP) outer sheath.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Flexible stranded tinned copper (Class 5) | NF EN 60228 Class 5 annealed tinned copper (1.5 to 150 mm²)Tin layer prevents sulphur vulcanisation attack and mine-water corrosion |
| 2 | Cross-linked Ethylene Propylene Rubber (EPR) | 90 °C high-grade thermoset EPR compound (colour-coded on Type 1A, numbered on Type 1B)Withstands thermal overloads and humid underground condensation |
| 3 | Extruded elastomeric inner bedding sheath | Pressure-extruded halogen-free/elastomeric inner covering filling core intersticesLocks the short-pitch cabled cores into a crush-resistant circular body |
| 4 | Heavy-duty Polychloroprene (PCP / Neoprene) outer | Cross-linked chloroprene elastomer (Black or Yellow, high tear and oil resistance)Passes NF C 32-070 C2 / IEC 60332-1-2 flame test and resists hydraulic fluids |
Unscreened flexible low-voltage power feeder for underground pumps, fans and auxiliary switchgear
Unscreened flexible multicore control, interlocking and tele-monitoring mining cable
Technical data
Sizes
0.6/1 kV unscreened EPR/PCP flexible power (Type 1A) and auxiliary control (Type 1B) cables.
| Order designation | Configuration | Voltage | Outer Ø ≈ mm | Copper kg/km | Weight ≈ kg/km | In air 30 °C A | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|---|
| SCGMS 19050 Type 1A — 0.6/1 kV Unscreened Flexible Mining Power Feeders | ||||||||
| SCGMS 19050 Type 1A 4G4 | 4G4 mm² | 0.6/1 kV | 16.2 | 154 | 375 | 36 | 97 | |
| SCGMS 19050 Type 1A 4G10 | 4G10 mm² | 0.6/1 kV | 21.8 | 384 | 720 | 63 | 131 | |
| SCGMS 19050 Type 1A 4G16 | 4G16 mm² | 0.6/1 kV | 25.0 | 614 | 1,020 | 84 | 150 | |
| SCGMS 19050 Type 1A 4G25 | 4G25 mm² | 0.6/1 kV | 29.5 | 960 | 1,490 | 112 | 177 | |
| SCGMS 19050 Type 1A 4G35 | 4G35 mm² | 0.6/1 kV | 32.8 | 1,344 | 1,940 | 138 | 197 | |
| SCGMS 19050 Type 1A 4G50 | 4G50 mm² | 0.6/1 kV | 37.6 | 1,920 | 2,650 | 168 | 226 | |
| SCGMS 19050 Type 1A 4G70 | 4G70 mm² | 0.6/1 kV | 42.5 | 2,688 | 3,580 | 213 | 255 | |
| SCGMS 19050 Type 1A 4G95 | 4G95 mm² | 0.6/1 kV | 47.8 | 3,648 | 4,690 | 258 | 287 | |
| SCGMS 19050 Type 1B — 0.6/1 kV Unscreened Auxiliary Control & Signalling Cables | ||||||||
| SCGMS 19050 Type 1B 7G1.5 | 7G1.5 mm² | 0.6/1 kV | 15.8 | 101 | 330 | 16 | 95 | |
| SCGMS 19050 Type 1B 12G2.5 | 12G2.5 mm² | 0.6/1 kV | 22.4 | 288 | 710 | 18 | 134 | |
| SCGMS 19050 Type 1B 19G1.5 | 19G1.5 mm² | 0.6/1 kV | 23.0 | 274 | 745 | 12 | 138 | |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| 3.0 kV AC 5-min dielectric withstand & Class 5 tinned-Cu resistance test | Zero breakdown; conductor resistance within NF EN 60228 limits | Every drum |
| Sample tests | ||
| PCP outer sheath hot-oil immersion, tear resistance & NF C 32-070 C2 flame test | Meets Charbonnages de France underground mining mechanical and flame criteria | Periodic audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.