Fixed installation
Compacted Class 2 aluminum or Class 5/K copper conductors with XLPE/EPR/HEPR insulation install cleanly in vertical tower cleats and trays
Product
Global Dual-Standard 1.8/3 (3.6) kV (IEC) & UL WTTC Compacted Al / Class 5 Cu HEPR EMC-Screened LSOH Wind Tower Cable (IEC 60502-1 / UL 2277 WTTC, 1.8/3 (3.6) kV / WTTC, -40 to +90 °C, min. bend radius 8 × OD).
Typical values for this cable type, based on IEC 60502-1 (1.8/3 kV) & UL 2277 WTTC EMC-Screened HEPR/LSOH Wind Tower Specification — confirmed in the datasheet and quotation for your order.
Application fit
Global Dual-Standard 1.8/3 (3.6) kV (IEC) & UL WTTC Compacted Al / Class 5 Cu HEPR EMC-Screened LSOH Wind Tower Cable (IEC 60502-1 / UL 2277 WTTC, 1.8/3 (3.6) kV / WTTC, -40 to +90 °C, min. bend radius 8 × OD).
Compacted Class 2 aluminum or Class 5/K copper conductors with XLPE/EPR/HEPR insulation install cleanly in vertical tower cleats and trays
Flexible DLO 2 kV, WTTC 1 kV and blade grounding builds absorb nacelle yaw loop torsion and rotor blade flexing down to −40 °C.
NSGAFOU 1.8/3 kV short-circuit-proof and UL WTTC/RHW-2 feeders wire directly into nacelle converter cabinets and tower base switchgear.
Heavy-duty CPE, HM4/HFFR LSZH and 5GM3 polychloroprene jackets resist turbine hydraulic oil, condensation, salt spray and UV.
Wind tower power feeders and large-cross-section DLO cables are not intended for high-cycle factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: 1.8/3 kV & UL WTTC Cu/Al EMC Tower (IEC 60502-1 (1.8/3 kV) & UL 2277 WTTC EMC-Screened HEPR/LSOH Wind Tower Specification) featuring class 2 compacted aluminum / class 5 copper, 1.8/3 (3.6) kv high-modulus hepr insulation and lsoh low-smoke zero-halogen outer sheath (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Class 2 Compacted Aluminum / Class 5 Cop | 50-630 mm² conductor engineered for vertical tower cleat fixing |
| 2 | 1.8/3 (3.6) kV High-Modulus HEPR Insulat | Thermoset HEPR dielectric certified to IEC and UL WTTC |
| 3 | Copper Tape / Wire EMC Screen | Metallic shield attenuating converter harmonic emissions in tower |
| 4 | LSOH Low-Smoke Zero-Halogen Outer Sheath | Flame-retardant halogen-free jacket for enclosed wind towers |
Built to IEC 60502-1 (1.8/3 kV) & UL 2277 WTTC EMC-Screened HEPR/LSOH Wind Tower Specification with class 2 compacted aluminum / class 5 copper and lsoh low-smoke zero-halogen outer sheath
Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths
Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report
Technical data
Sizes
Manufactured to IEC 60502-1 (1.8/3 kV) & UL 2277 WTTC EMC-Screened HEPR/LSOH Wind Tower Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 1.8/3 kV & UL WTTC Cu/Al EMC Tower Construction Schedule (−40…+90 °C) | |||||||
| 1.8/3 kV & UL WTTC Cu/ 1×150 / 4×95 Al | 1 × 150 mm² (or 4 × 95 mm² Al) | Class 2 Compacted Al / Class 5 AA8000 | 23.5 | 640 | 10.5 | 190 | |
| 1.8/3 kV & UL WTTC Cu/ 1×240 / 4×150 Al | 1 × 240 mm² (or 4 × 150 mm² Al) | Class 2 Compacted Al / Class 5 AA8000 | 28.4 | 980 | 16.8 | 230 | |
| 1.8/3 kV & UL WTTC Cu/ 1×400 / 4×240 Al | 1 × 400 mm² (or 4 × 240 mm² Al) | Class 2 Compacted Al / Class 5 AA8000 | 35.8 | 1,590 | 28.0 | 290 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 1 × 150 mm² (or 4 × 95 mm² Al) | 0.21 | 1.8/3 (3.6) kV / WTTC (315 A Al) | −40…+90 °C |
| 1 × 240 mm² (or 4 × 150 mm² Al) | 0.13 | 1.8/3 (3.6) kV / WTTC (435 A Al) | −40…+90 °C |
| 1 × 400 mm² (or 4 × 240 mm² Al) | 0.08 | 1.8/3 (3.6) kV / WTTC (590 A Al) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance & dimensional verification (IEC 60502-1 (1.8/3 kV) & UL 2277 WTTC EMC-Screened HEPR/LSOH Wind Tower Specification) | DC resistance at 20 °C and insulation/sheath wall thickness within IEC 60502-1 (1.8/3 kV) & UL 2277 WTTC EMC-Screened HEPR/LSOH Wind Tower Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (IEC 60502-1 (1.8/3 kV) & UL 2277 WTTC EMC-Screened HEPR/LSOH Wind Tower Specification) | Zero dielectric breakdown and verified insulation resistance for 1.8/3 (3.6) kV / WTTC rating | Every manufactured drum length |
| Sample tests | ||
| Low-temperature drip-loop torsion, oil & flame qualification (IEC 60502-1 (1.8/3 kV) & UL 2277 WTTC EMC-Screened HEPR/LSOH Wind Tower Specification) | Verified cold torsion cycle endurance, oil resistance and flame retardancy across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ