Motor stator, traction & converter leads
Terminates directly onto 3.6/6 kV, 6/10 kV and 12/20 kV motor terminal studs and transformer bushings where space is too short for a.
Product
NTMCWÖU (and (N)TMCWÖU) Extra-Flexible Single-Core Medium-Voltage Connection Cable (3.6/6 kV, 6/10 kV, 12/20 kV & 18/30 kV; 16 mm² to 500 mm²) engineered to DIN VDE 0250-813 with Class 5 fine-stranded tinned copper conductor, inner.
Typical values for this cable type, based on DIN VDE 0250-813 — confirmed in the datasheet and quotation for your order.
Application fit
Because NTMCWÖU has an inner semiconducting conductor stress screen ('C') and thick 3GI3 EPR + 5GM3 rubber sheath without an outer metallic screen, it terminates with a simple crimp lug—no MV stress-cone kit required—making it the fastest, most compact jumper for enclosed MV switchgear, motors and transformers.
Terminates directly onto 3.6/6 kV, 6/10 kV and 12/20 kV motor terminal studs and transformer bushings where space is too short for a.
5 × OD minimum bend radius routes effortlessly between circuit breakers, contactors, current transformers and busbars inside.
5GM3 polychloroprene ('WÖU') rubber jacket resists transformer oil, condensation, ozone and IEC 60332-1-2 flame propagation.
Unscreened MV cable: outer surface is not touch-safe under voltage and must be installed inside closed switchgear cabinets, on.
Use Screened (N)TMCGC11YConstruction
NTMCWÖU Extra-Flexible Single-Core MV Connection Cable showing Class 5 fine-stranded tinned copper conductor, extruded inner semiconducting elastomer stress-equalizing layer ('C'), +90 °C 3GI3 ethylene propylene rubber (EPR) MV insulation, inner elastomer layer, and Black or Red 5GM3 weather/oil-resistant polychloroprene ('WÖU') outer sheath.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Class 5 fine-stranded tinned copper conductor | Electrolytic tin-coated annealed flexible copper wires per IEC 60228 / DIN VDE 0295 Class 5 (16 mm² to 500 mm²)Tight 5 × OD bend radius and low terminal bushing mechanical load |
| 2 | Extruded inner semiconducting elastomer layer ('C') | Vulcanized semiconducting rubber layer bonded over the stranded conductorEqualizes electric stress at the conductor surface to prevent internal corona |
| 3 | 3GI3 Ethylene Propylene Rubber (EPR) MV dielectric | 90 °C ozone-, corona- and heat-resistant thermoset EPR compound Type 3GI3 per DIN VDE 0207-20High dielectric withstand without requiring an outer metallic screen |
| 4 | 5GM3 Polychloroprene ('WÖU') weather & oil-resistant sheath | Heavy-duty cross-linked polychloroprene rubber compound Type 5GM3 per DIN VDE 0207-21 in Black or RedW = Weatherproof · Ö = Oil-resistant · U = Flame-retardant |
Unscreened flexible MV jumper cable for 3.3 kV, 6.6 kV and 10/11 kV motor terminal boxes and switchgear cells
Unscreened flexible MV connection cable for 15 kV, 20 kV and 30 kV transformer cubicles and dry-type coil leads
Technical data
Sizes
Cross-section, voltage class, nominal outer diameter, weight, DC resistance and free-air ampacity.
| VDE designation | Conductor & voltage | Outer Ø ≈ mm | Weight ≈ kg/km | Max. DC R Ω/km | Air 30°C A | Enquiry |
|---|---|---|---|---|---|---|
| 6/10 kV NTMCWÖU Unscreened | ||||||
| NTMCWÖU 1×35 6/10kV | 1 × 35 mm² Cl.5 Tinned Cu · 6/10 kV | 19.8 | 580 | 0.5650 | 198 | |
| NTMCWÖU 1×70 6/10kV | 1 × 70 mm² Cl.5 Tinned Cu · 6/10 kV | 23.6 | 965 | 0.2770 | 305 | |
| NTMCWÖU 1×120 6/10kV | 1 × 120 mm² Cl.5 Tinned Cu · 6/10 kV | 27.8 | 1,490 | 0.1640 | 430 | |
| NTMCWÖU 1×240 6/10kV | 1 × 240 mm² Cl.5 Tinned Cu · 6/10 kV | 35.2 | 2,760 | 0.0817 | 680 | |
| 12/20 kV (N)TMCWÖU Unscreened | ||||||
| (N)TMCWÖU 1×50 12/20kV | 1 × 50 mm² Cl.5 Tinned Cu · 12/20 kV | 25.4 | 890 | 0.3930 | 248 | |
| (N)TMCWÖU 1×150 12/20kV | 1 × 150 mm² Cl.5 Tinned Cu · 12/20 kV | 33.4 | 1,950 | 0.1320 | 500 | |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| 100 % High-voltage AC water-bath dielectric test (11–43 kV for 5 min) | Zero breakdown across entire 3GI3 EPR + 5GM3 rubber wall | Every manufactured drum |
| Sample tests | ||
| 5GM3 polychloroprene hot-oil immersion, tensile & IEC 60332-1-2 flame | Meets DIN VDE 0207-21 mechanical and oil retention limits | Per production batch |
| DIN VDE 0207-20 high-concentration ozone & corona endurance test | Zero surface ozone cracking when bent around mandrel under HV stress | Type qualification |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.