Contact

SAF Submerged Arc Furnace Water-Cooled Feeder CableHigh-current multi-rope water-cooled rubber hose cable for ferroalloy SAF furnaces

SAF Water-Cooled Cable strands extra-flexible Class 6 bare copper ropes around a central coolant channel inside a reinforced black EPDM rubber hose for continuous 1,000 V submerged-arc furnace electrode feeds.

Flame-retardant
Oil-resistant
Approved
Order designation
SAF Water-Cooled Cable 1×630 mm²
Outer Ø
72.0 mm
Max. R20
0.029 Ω/km
Weight
12,684 kg/km
Min. bend R
576 mm
All sizes (7)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
1000 V
Test voltage 4 kV AC
Temp. (fixed)
-25°C…+90°C
Flexing: -20 °C to +80 °C
Strength / Armor
Water Hose
High-tensile woven
Min. bend radius
8 × OD
High-current flexible routing
Conductor
Bare Cu · Cl.6
Per DIN VDE 0250 (ref.)
Size range
1×300–1×1200
7 standard configurations

Typical values for this cable type, based on DIN VDE 0250 (ref.) · IEC 60228 Class 6 · EN 50363-2-1 — confirmed in the datasheet and quotation for your order.

Application fit

Is SAF Water-Cooled Cable right for your machine?

SAF Water-Cooled Cable strands extra-flexible Class 6 bare copper ropes around a central coolant channel inside a reinforced black EPDM rubber hose for continuous 1,000 V submerged-arc furnace electrode feeds.

Furnace, kiln & high-temp zone

Suitable

Thermal-rated 1000 V EPDM build delivers stable high-current power near furnaces, ovens, kilns, and molten-metal zones.

Fixed installation

Suitable

Durable 1000 V EPDM geometry installs cleanly along transformer links, busbar transitions, trays, and industrial bays.

Cable trench & heavy drive bay

Suitable

Rugged 1000 V EPDM construction handles stationary heavy-plant cable trenches, rolling-mill feeders, and industrial power bays.

High-temperature boiler & thermal plant

Suitable

Thermal-aged 1000 V EPDM insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.

Energy chain / drag chain

Not suitable

1000 V EPDM construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Immersion & wet locations

Not suitable

1000 V EPDM outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesElectric arc (EAF) & submerged arc (SAF) steelworksMedium- & high-frequency induction melting foundriesAutomotive robotic spot- & seam-welding linesHeavy DC rectifiers & metallurgical bus feeders

Construction

Layer by layer

Representative construction of SAF Water-Cooled Cable: IEC 60228 Class 6 extra-flexible bare annealed copper, Central high-pressure EPDM coolant tube + multi-rope copper assembly, and Black textile-reinforced heat- & splash-resistant EPDM rubber outer hose.

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorIEC 60228 Class 6 extra-flexible bare annealed copperIEC 60228 Class 6
2Cooling core / primary dielectricCentral high-pressure EPDM coolant tube + multi-rope copper assemblyDIN VDE 0250 (ref.)
3Strength / pressure reinforcementHigh-tensile woven synthetic/fibreglass pressure reinforcement braidDIN VDE 0250 (ref.)
4Outer sheath / hoseBlack textile-reinforced heat- & splash-resistant EPDM rubber outer hoseContinuous Water Cooling

SAF Water-Cooled Cable High-Duty

Single-core high-duty construction protected by Black textile-reinforced heat- & splash-resistant EPDM rubber outer hose.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0250 (ref.) · IEC 60228 Class 6 · EN 50363-2-1. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
1000 V
Test voltage
4 kV AC
Conductor
Bare Cu · Cl.6
Core / dielectric
Central high-pressure EPDM coolant tube +
Impedance / insulation
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-25 °C to +90 °C
Temp. range (flexing)
-20 °C to +80 °C
Peak / short-circuit
+160 °C (5 s)
Min. bending radius
8 × OD

Resistance

Primary performance
Continuous Water Cooling
Environment / duty
Flame & Slag Resistant EPDM
Mechanical / special
Up to 10 kA Furnace Duty
Outer finish
Black textile-reinforced heat- &

Sizes

Water-Cooled High-Current Sizes (mm²)
Cross-section
mm²
Outer Ø ≈
mm
Max. R20
Ω/km
Copper index
kg/km
Weight ≈
kg/km
Min. bend R
8×D mm
1×300 mm²55.20.0642,8806,456442
1×400 mm²61.00.0493,8408,362488
1×500 mm²66.10.0384,80010,250529
1×630 mm²72.00.0296,04812,684576
1×800 mm²78.80.0247,68015,837630
1×1000 mm²86.00.0199,60019,533688
1×1200 mm²92.50.01611,52023,210740
  • Conductor DC resistance R20 at 20 °C per IEC 60228 Class 6.
  • Minimum bending radius calculated at 8 × nominal outer diameter (OD). Custom terminations available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Hydrostatic pressure & dielectric test4 kV AC without breakdownEvery manufactured length
Continuity & conductor DC resistancePer IEC 60228 Class 6 at 20 °CEvery drum / assembly
Sample tests
Tensile, dimensional & pressure checkRated -25 °C to +90 °C continuousPer production lot
Environmental, thermal & mechanical qualificationContinuous Water Cooling · Flame & Slag Resistant EPDMType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DIN VDE 0250 (ref.)IEC 60228 Class 6EN 50363-2-1EN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

SAF Water-Cooled Cable 1000 V TEBAOFLEX.COM [DIN VDE 0250 (ref.)] [Size] [Metre mark]
Delivery form
Custom assemblies, coils or export drums
Standard lengths
Cut-to-length · 100 m · 500 m · 1,000 m
MOQ
1 assembly / 50 m (stock) · 300 m (custom)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-23
Updated
2026-11-23

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes SAF Water-Cooled Cable suited for demanding 1000 V installations?
SAF Water-Cooled Cable combines IEC 60228 Class 6 extra-flexible bare annealed copper with Central high-pressure EPDM coolant tube + multi-rope copper assembly and Black textile-reinforced heat- & splash-resistant EPDM rubber outer hose. Internal water circulation removes I²R Joule heat so compact cross-sections safely deliver extreme SAF currents.
What minimum bending radius should be respected for SAF Water-Cooled Cable?
Maintain a minimum bending radius of 8 × OD across -20 °C to +80 °C flexing temperatures to ensure long mechanical and dielectric service life.
Can SAF Water-Cooled Cable be delivered pre-terminated with custom lugs, water fittings, or subsea connectors?
Yes. TEBAOFLEX supplies SAF Water-Cooled Cable either in bulk lengths or factory-assembled with copper lugs, water-cooled swivel fittings, or molded subsea wet-mate connectors.
What quality tests and certificates accompany every shipment of SAF Water-Cooled Cable?
SAF Water-Cooled Cable conforms to DIN VDE 0250 (ref.), IEC 60228 Class 6, EN 50363-2-1 (Continuous Water Cooling) and ships with an EN 10204 3.1 routine factory test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for SAF Water-Cooled Cable

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

SAF Submerged Arc Furnace Water-Cooled Feeder Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp