Contact

WC Unipolar 120–500 mm² Water-Cooled Welding CableTinned copper unipolar annular water-cooled cable for heavy spot welding

WC Unipolar Weld 120–500 surrounds an extra-flexible tinned copper core with an annular water-cooling jacket, braided reinforcement, and black rubber outer hose for high-duty resistance and seam welding machines.

Flame-retardant
Oil-resistant
Approved
Order designation
WC Unipolar Weld Cable 1×240 mm²
Outer Ø
51.3 mm
Max. R20
0.082 Ω/km
Weight
5,305 kg/km
Min. bend R
410 mm
All sizes (7)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V
Test voltage 3 kV AC
Temp. (fixed)
-20°C…+85°C
Flexing: -15 °C to +75 °C
Strength / Armor
Water Hose
Synthetic textile pressure
Min. bend radius
8 × OD
High-current flexible routing
Conductor
Tinned Cu · Cl.6
Per ISO 5828 (ref.)
Size range
1×120–1×500
7 standard configurations

Typical values for this cable type, based on ISO 5828 (ref.) · IEC 60228 Class 6 · DIN VDE 0282 — confirmed in the datasheet and quotation for your order.

Application fit

Is WC Unipolar Weld Cable right for your machine?

WC Unipolar Weld 120–500 surrounds an extra-flexible tinned copper core with an annular water-cooling jacket, braided reinforcement, and black rubber outer hose for high-duty resistance and seam welding machines.

Furnace, kiln & high-temp zone

Suitable

Thermal-rated 600 V EPDM build delivers stable high-current power near furnaces, ovens, kilns, and molten-metal zones.

Fixed installation

Suitable

Durable 600 V EPDM geometry installs cleanly along transformer links, busbar transitions, trays, and industrial bays.

Welding power source & electrode lead

Suitable

Extra-flexible heat- and spatter-resistant 600 V EPDM build delivers low-drop current to welding tongs and shop floor leads.

Factory automation tray & machine bus

Suitable

Flexible oil-resistant 600 V EPDM construction routes cleanly along factory automation trays, machine frames, and production lines.

Energy chain / drag chain

Not suitable

600 V EPDM construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Immersion & wet locations

Not suitable

600 V EPDM outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesElectric arc (EAF) & submerged arc (SAF) steelworksMedium- & high-frequency induction melting foundriesAutomotive robotic spot- & seam-welding linesHeavy DC rectifiers & metallurgical bus feeders

Construction

Layer by layer

Representative construction of WC Unipolar Weld Cable: IEC 60228 Class 6 extra-flexible tinned annealed copper, Annular deionized-water cooling jacket surrounding tinned copper core, and Black abrasion- & oil-resistant reinforced EPDM rubber outer hose.

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorIEC 60228 Class 6 extra-flexible tinned annealed copperIEC 60228 Class 6
2Cooling core / primary dielectricAnnular deionized-water cooling jacket surrounding tinned copper coreISO 5828 (ref.)
3Strength / pressure reinforcementSynthetic textile pressure reinforcement braidISO 5828 (ref.)
4Outer sheath / hoseBlack abrasion- & oil-resistant reinforced EPDM rubber outer hoseCorrosion-Proof Tinned Cu

WC Unipolar Weld Cable High-Duty

Single-core high-duty construction protected by Black abrasion- & oil-resistant reinforced EPDM rubber outer hose.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on ISO 5828 (ref.) · IEC 60228 Class 6 · DIN VDE 0282. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
600 V
Test voltage
3 kV AC
Conductor
Tinned Cu · Cl.6
Core / dielectric
Annular deionized-water cooling jacket
Impedance / insulation
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-20 °C to +85 °C
Temp. range (flexing)
-15 °C to +75 °C
Peak / short-circuit
+160 °C (5 s)
Min. bending radius
8 × OD

Resistance

Primary performance
Corrosion-Proof Tinned Cu
Environment / duty
Annular Water Cooling
Mechanical / special
High-Cycle Flex Hose
Outer finish
Black abrasion- & oil-resistant

Sizes

Water-Cooled High-Current Sizes (mm²)
Cross-section
mm²
Outer Ø ≈
mm
Max. R20
Ω/km
Copper index
kg/km
Weight ≈
kg/km
Min. bend R
8×D mm
1×120 mm²41.60.1661,1522,951333
1×150 mm²44.30.1331,4403,544354
1×185 mm²47.20.1091,7764,233378
1×240 mm²51.30.0822,3045,305410
1×300 mm²55.20.0662,8806,456442
1×400 mm²61.00.0503,8408,362488
1×500 mm²66.10.0404,80010,250529
  • Conductor DC resistance R20 at 20 °C per IEC 60228 Class 6.
  • Minimum bending radius calculated at 8 × nominal outer diameter (OD). Custom terminations available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Hydrostatic pressure & dielectric test3 kV AC without breakdownEvery manufactured length
Continuity & conductor DC resistancePer IEC 60228 Class 6 at 20 °CEvery drum / assembly
Sample tests
Tensile, dimensional & pressure checkRated -20 °C to +85 °C continuousPer production lot
Environmental, thermal & mechanical qualificationCorrosion-Proof Tinned Cu · Annular Water CoolingType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

ISO 5828 (ref.)IEC 60228 Class 6DIN VDE 0282EN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

WC Unipolar Weld Cable 600 V TEBAOFLEX.COM [ISO 5828 (ref.)] [Size] [Metre mark]
Delivery form
Custom assemblies, coils or export drums
Standard lengths
Cut-to-length · 100 m · 500 m · 1,000 m
MOQ
1 assembly / 50 m (stock) · 300 m (custom)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-23
Updated
2026-11-23

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes WC Unipolar Weld Cable suited for demanding 600 V installations?
WC Unipolar Weld Cable combines IEC 60228 Class 6 extra-flexible tinned annealed copper with Annular deionized-water cooling jacket surrounding tinned copper core and Black abrasion- & oil-resistant reinforced EPDM rubber outer hose. Tin-plated copper strands resist water oxidation and galvanic scaling in closed-loop welding cooling circuits.
What minimum bending radius should be respected for WC Unipolar Weld Cable?
Maintain a minimum bending radius of 8 × OD across -15 °C to +75 °C flexing temperatures to ensure long mechanical and dielectric service life.
Can WC Unipolar Weld Cable be delivered pre-terminated with custom lugs, water fittings, or subsea connectors?
Yes. TEBAOFLEX supplies WC Unipolar Weld Cable either in bulk lengths or factory-assembled with copper lugs, water-cooled swivel fittings, or molded subsea wet-mate connectors.
What quality tests and certificates accompany every shipment of WC Unipolar Weld Cable?
WC Unipolar Weld Cable conforms to ISO 5828 (ref.), IEC 60228 Class 6, DIN VDE 0282 (Corrosion-Proof Tinned Cu) and ships with an EN 10204 3.1 routine factory test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for WC Unipolar Weld Cable

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

WC Unipolar 120–500 mm² Water-Cooled Welding Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote