submarine & offshore power composite cableNEK TS 606 / IEC 60092-353 RFOU0.6/1 kV (-40 to +90 °C)SHF1 / SHF2-MUD Halogen-Free Outer S

TXXI / TXOI / RFOU 0.6/1 kV IEC 60092-353 & NEK TS 606 Nordic Halogen-Free Marine & Offshore CableNEK TS 606 / IEC 60092-353 RFOU — 0.6/1 kV — -40 to +90 °C Subsea & Offshore Cable

TXXI / TXOI / RFOU 0.6/1 kV IEC 60092-353 & NEK TS 606 Nordic Halogen-Free Marine & Offshore Cable (NEK TS 606 / IEC 60092-353 RFOU) engineered for 0.6/1 kV service across -40 to +90 °C (min. bend radius 6 × OD).

Water-resistant
Flame-retardant
Oil-resistant
Approved
Order designation
TXXI 3×16+1G16 mm²
Outer Ø ≈
22.4 mm
Net weight ≈
920 kg/km
Tensile rating ≈
18.5 kN
Core / stranding
IEC 60228 Class 2/5 Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per NEK TS 606 / IEC 60092-353 RF
Operating temp.
−40…+90 °C
Continuous subsea & offshore service
Min. bend radius
6 × OD
Winch sheave, chute & seabed routing
Core / conductor
Class 2 / Class
Stranded tinned annealed copper power an
Outer protection
SHF1 / SHF2-MUD
Flame-retardant oil- and mud-resistant o
Standard
NEK TS 606 / IEC
NEK TS 606 Code P1/P8 (RFOU) & Nordic TX

Typical values for this cable type, based on NEK TS 606 Code P1/P8 (RFOU) & Nordic TXXI/TXOI 0.6/1 kV SHF1/SHF2-MUD Marine Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is TXXI / TXOI / RFOU 0.6/1kV right for your machine?

TXXI / TXOI / RFOU 0.6/1 kV IEC 60092-353 & NEK TS 606 Nordic Halogen-Free Marine & Offshore Cable (NEK TS 606 / IEC 60092-353 RFOU) engineered for 0.6/1 kV service across -40 to +90 °C (min. bend radius 6 × OD).

Offshore platform & shipboard deck trays

Suitable

Halogen-free SHF1/SHF2, IEEE 1580 Type P or PE/PP submarine outer serving withstands marine salt mist, drilling mud and seabed/deck duty.

Fixed installation

Suitable

Approved for submarine seabed burial, J-tube pull-in, offshore platform cable ladders and shipboard bulkhead penetrations.

Immersion & wet locations

Suitable

Extruded lead-alloy radial water barrier or cross-linked marine elastomer sheath prevents moisture ingress in subsea and wet-deck service.

Motor stator, traction & converter leads

Suitable

Compacted copper or extra-flexible Class I/K tinned copper conductors terminate cleanly into offshore switchboards, transformers and thrus

Energy chain / drag chain

Not suitable

Submarine and armoured offshore power cable is not designed for high-cycle automation drag chains.

Use Drag-Chain Servo Cable
Typical machinesMarine & Offshore CableOffshore Wind Inter-Array & Export Submarine LinksSubsea Island & Platform HV/MV Power InterconnectsOffshore Oil & Gas Drilling Rigs & FPSOsCommercial Vessels, Polar Ships & Marine Propulsion

Construction

Layer by layer

Shown: TXXI / TXOI / RFOU 0.6/1kV (NEK TS 606 Code P1/P8 (RFOU) & Nordic TXXI/TXOI 0.6/1 kV SHF1/SHF2-MUD Marine Specification) featuring class 2 / class 5 tinned copper conductors, halogen-free xlpe / epr core insulation and shf1 / shf2-mud halogen-free outer sheath (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Class 2 / Class 5 Tinned Copper ConductoStranded tinned annealed copper power and control cores
2Halogen-Free XLPE / EPR Core Insulation90 °C cross-linked polyethylene or EPR insulation
3Tinned Copper Wire Braid (TXOI / RFOU)High-coverage tinned copper wire braid screen and armour
4SHF1 / SHF2-MUD Halogen-Free Outer SheatFlame-retardant oil- and mud-resistant offshore jacket

TXXI / TXOI / RFOU 0.6/1kV — Standard Subsea & Offshore Execution

Built to NEK TS 606 Code P1/P8 (RFOU) & Nordic TXXI/TXOI 0.6/1 kV SHF1/SHF2-MUD Marine Specification with class 2 / class 5 tinned copper conductors and shf1 / shf2-mud halogen-free outer sheath

TXXI / TXOI / RFOU 0.6/1kV — Custom Continuous Winch / Reel Length

Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations

TXXI / TXOI / RFOU 0.6/1kV — Hydrostatic, Tensile & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on NEK TS 606 Code P1/P8 (RFOU) & Nordic TXXI/TXOI 0.6/1 kV SHF1/SHF2-MUD Marine Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (NEK TS 606 Code P1/P8 (RFOU) & Nordic TXXI/TXOI 0.6/1 kV SHF1/SHF2-MUD Marine Specification)
Core / conductor construction
Class 2 / Class 5 Tinned Copper Conductors — Stranded tinned annealed copper power and control cores
Primary dielectric / buffering
Halogen-Free XLPE / EPR Core Insulation — 90 °C cross-linked polyethylene or EPR insulation

Thermal

Continuous operating temperature
−40…+90 °C (subsea & offshore duty)
Hydrostatic & thermal stability
Verified thermal and hydrostatic stability per NEK TS 606 Code P1/P8 (RFOU) & Nordic TXXI/TXOI 0.6/1 kV SHF1/SHF2-MUD Marine Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel winch reel

Mechanical

Outer protection / armouring
SHF1 / SHF2-MUD Halogen-Free Outer Sheath — Flame-retardant oil- and mud-resistant offshore jacket
Minimum bending radius
6 × OD
Armour, strength member & mechanical duty
Tinned Copper Wire Braid (TXOI / RFOU) — High-coverage tinned copper wire braid screen and armour

Resistance

Seawater, hydrostatic & hydrolysis resistance
Engineered for continuous seawater immersion, pressure cycling and hydrolysis resistance per NEK TS 606 Code P1/P8 (RFOU) & Nordic TXXI/TXOI 0.6/1 kV SHF1/SHF2-MUD Marine Specification
Oil, drilling mud & abrasion resistance
Resistant to marine hydraulic oils, salt mist, winch sheave wear and seabed abrasion per NEK TS 606 Code P1/P8 (RFOU) & Nordic TXXI/TXOI 0.6/1 kV SHF1/SHF2-MUD Marine Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
NEK TS 606 Code P1/P8 (RFOU) & Nordic TXXI/TXOI 0.6/1 kV SHF1/SHF2-MUD Marine Specification
Environmental & test standards
IEC 60228 / IEC 60794 / ITU-T G.972 / IEEE 1580 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
TXXI / TXOI / RFOU 0.6/1kV
Sheath colour & metre marking
Continuous metre-marked black outer finish (SHF1 / SHF2-MUD )
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard TXXI / TXOI / RFOU 0.6/1kV subsea & offshore configurations

Manufactured to NEK TS 606 Code P1/P8 (RFOU) & Nordic TXXI/TXOI 0.6/1 kV SHF1/SHF2-MUD Marine Specification for subsea, oceanographic, ROV, seismic and offshore applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Breaking / tensile
kN ≈
Min. bend R
mm
Enquiry
TXXI / TXOI / RFOU 0.6/1kV Construction Schedule (−40…+90 °C)
TXXI 3×16+1G16 mm²3 × 16 + 1G16 mm² (or 1C×50 mm²)IEC 60228 Class 2/5 Cu/SnCu22.492018.5135
TXXI 3×35+1G16 mm²3 × 35 + 1G16 mm² (or 1C×150 mm²)IEC 60228 Class 2/5 Cu/SnCu28.81,69032.0175
TXXI 3×95+1G50 mm²3 × 95 + 1G50 mm² (or 1C×300 mm²)IEC 60228 Class 2/5 Cu/SnCu41.23,68058.0250
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour breaking loads and continuous winch/seabed lengths available per NEK TS 606 Code P1/P8 (RFOU) & Nordic TXXI/TXOI 0.6/1 kV SHF1/SHF2-MUD Marine Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, optical OTDR continuity & dimensional verification (NEK TS 606 Code P1/P8 (RFOU) & Nordic TXXI/TXOI 0.6/1 kV SHF1/SHF2-MUD Marine Specification)DC resistance at 20 °C / optical attenuation and outer diameter within NEK TS 606 Code P1/P8 (RFOU) & Nordic TXXI/TXOI 0.6/1 kV SHF1/SHF2-MUD Marine Specification tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (NEK TS 606 Code P1/P8 (RFOU) & Nordic TXXI/TXOI 0.6/1 kV SHF1/SHF2-MUD Marine Specification)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile breaking load & water-blocking qualification (NEK TS 606 Code P1/P8 (RFOU) & Nordic TXXI/TXOI 0.6/1 kV SHF1/SHF2-MUD Marine Specification)Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

NEK TS 606 / IEC 60092-353 RFOU CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX TXXI / TXOI / RFOU 0.6/1kV NEK TS 606 / IEC 60092-353 RFOU 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums, steel oceanographic winch reels or submarine turntables
Standard lengths
500 m, 1,000 m, 3,000 m, 6,000 m or custom continuous subsea lengths
MOQ
100 m (standard configurations) · 500 m (custom subsea builds)
Lead time
2–6 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-26
Updated
2026-10-26

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define TXXI / TXOI / RFOU 0.6/1kV (TXXI / TXOI / RFOU 0.6/1 kV IEC 60092-353 & NEK TS 606 Nordic Halogen-Free Marine & Offshore Cable)?
TXXI / TXOI / RFOU 0.6/1kV (TXXI / TXOI / RFOU 0.6/1 kV IEC 60092-353 & NEK TS 606 Nordic Halogen-Free Marine & Offshore Cable) is manufactured in accordance with NEK TS 606 Code P1/P8 (RFOU) & Nordic TXXI/TXOI 0.6/1 kV SHF1/SHF2-MUD Marine Specification for 0.6/1 kV service over -40 to +90 °C. Its 4-layer construction comprises class 2 / class 5 tinned copper conductors, halogen-free xlpe / epr core insulation and shf1 / shf2-mud halogen-free outer sheath.
What is the minimum bending radius and operating temperature range for TXXI / TXOI / RFOU 0.6/1kV?
The minimum bending radius for TXXI / TXOI / RFOU 0.6/1kV is 6 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical, hydrostatic and dielectric reliability in subsea and offshore service.
How are the concentric layers of TXXI / TXOI / RFOU 0.6/1kV arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Class 2 / Class 5 Tinned Copper Conductors — Stranded tinned annealed copper power and control cores; (02) Halogen-Free XLPE / EPR Core Insulation — 90 °C cross-linked polyethylene or EPR insulation; (03) Tinned Copper Wire Braid (TXOI / RFOU) — High-coverage tinned copper wire braid screen and armour; (04) SHF1 / SHF2-MUD Halogen-Free Outer Sheath — Flame-retardant oil- and mud-resistant offshore jacket.
What factory test certificates are supplied with TXXI / TXOI / RFOU 0.6/1kV?
Every production drum of TXXI / TXOI / RFOU 0.6/1kV undergoes routine conductor resistance/OTDR continuity, high-voltage dielectric and dimensional testing per NEK TS 606 Code P1/P8 (RFOU) & Nordic TXXI/TXOI 0.6/1 kV SHF1/SHF2-MUD Marine Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for TXXI / TXOI / RFOU 0.6/1kV

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

TXXI / TXOI / RFOU 0.6/1 kV IEC 60092-353 & NEK TS 606 Nordic Halogen-Free Marine & Offshore Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote