Fixed installation
Approved for open cable tray, raceway and supported industrial runs per standard installation rules.
Product
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Typical values for this cable type, based on Reference specification per SMPTE 311M / UL 1666 CMR (2824RW SMPTE 311M CMR) — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Approved for open cable tray, raceway and supported industrial runs per standard installation rules.
Controlled characteristic impedance and low mutual capacitance preserve signal eye opening over long trunks.
Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.
Outer sheath compound resists industrial cutting fluids, mineral oils and outdoor sunlight.
Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.
Use TRA 0.6/1 kV PUR Reeling CableControlled-impedance 300/600 V CPE/PVC construction delivers low-attenuation telemetry across industrial Ethernet, fieldbus, and control racks.
Construction
Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

| # | Layer | Material & reference |
|---|---|---|
| 1 | 3 Foil-Shielded Copper Quads (6×18 + 6×24 AWG) | 3 Quads × (2×18 AWG Aux + 2×24 AWG Ctrl + TC Drain) |
| 2 | 6× OS2 (G.657.A2) Tight-Buffered Optical Subunits | 6× 900 µm Singlemode Fibers + Aramid + 2.1mm PVC Jackets |
| 3 | Individual 100% Aluminum/Polyester Quad Shields | 3× Individual Quad Foil Shields + Tinned Cu Drain Wires |
| 4 | Polymeric Fillers + Water-Blocking Tape Wrap | Central & Interstitial Fillers + Dry Waterblocking Tape |
| 5 | Sunlight & Water-Resistant Black CPE Outer Jacket | UL 1666 CMR Chlorinated Elastomer (CPE) Sheath (22.6 mm OD) |
OS2 G.657.A2 + Tinned Cu Quads + Foil + Waterblock · Outer diameter 22.6 mm.
OS2 G.657.A2 + Tinned Cu Quads + Foil + Waterblock · Outer diameter 19.4 mm.
OS2 G.657.A2 + Tinned Cu Quads + Foil + Waterblock · Outer diameter 25.8 mm.
Technical data
Sizes
Representative configurations from the series specification; select a row to prefill the quotation tool.
| Configuration | Conductor & shield | Insulation / wall | Outer sheath | Outer diameter mm | Min. bend radius mm | Max. conductor resistance @ 20 °C Ω/km | Copper weight kg/km | Cable weight kg/km | Key electrical / optical rating | Part designation | Enquiry |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 2824RW SMPTE 311M CMR | |||||||||||
| 6F OS2 + 3 Quads (6×18 + 6×24 AWG) | OS2 G.657.A2 + Tinned Cu Quads + Foil + Waterblock | 6× 900 µm Singlemode Fibers + Aramid + 2.1mm PVC Jackets | CPE Elastomer | 22.6 | 226 | 21.40 | 68.0 | 565 | ≤ 0.40 dB/km @ 1310 nm · 300/600 V | 2824RW 3-Ch (6F OS2 + 6×18 AWG + 6×24 AWG) | |
| 4F OS2 + 2 Quads (4×18 + 4×24 AWG) | OS2 G.657.A2 + Tinned Cu Quads + Foil + Waterblock | 6× 900 µm Singlemode Fibers + Aramid + 2.1mm PVC Jackets | CPE Elastomer | 19.4 | 194 | 21.40 | 45.5 | 390 | ≤ 0.40 dB/km @ 1310 nm · 300/600 V | 2824RW-2 2-Ch (4F OS2 + 4×18 AWG + 4×24 AWG) | |
| 8F OS2 + 4 Quads (8×18 + 8×24 AWG) | OS2 G.657.A2 + Tinned Cu Quads + Foil + Waterblock | 6× 900 µm Singlemode Fibers + Aramid + 2.1mm PVC Jackets | CPE Elastomer | 25.8 | 258 | 21.40 | 91.0 | 740 | ≤ 0.40 dB/km @ 1310 nm · 300/600 V | 2824RW-4 4-Ch (8F OS2 + 8×18 AWG + 8×24 AWG) | |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & continuity | Within maximum Ω/km limit at 20 °C | Every manufactured drum length |
| Dielectric withstand / spark test | No breakdown across insulation or shield | Every manufactured drum length |
| Sample tests | ||
| Vertical flame propagation & jacket qualification | Self-extinguishing within standard char limit | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.