Contact
fire-resistant shipboard & offshore cableIEEE 1580 / IEC 60331-21 Type P-331H0.6/1 kV – 15 kV (-40 to +125 °C)SHF2 Low-Smoke Zero-Halogen Outer Ja

IEEE 1580 Type P-331HF & IEC 60331 0.6/1–15 kV Mica-Taped Fire-Resistant SHF2 Offshore Power CableIEEE 1580 / IEC 60331-21 Type P-331HF — 0.6/1 kV – 15 kV — -40 to +125 °C Subsea & Offshore Cable

IEEE 1580 Type P-331HF & IEC 60331 0.6/1–15 kV Mica-Taped Fire-Resistant SHF2 Offshore Power Cable (IEEE 1580 / IEC 60331-21 Type P-331HF) engineered for 0.6/1 kV – 15 kV service across -40 to +125 °C (min. bend radius 8 × OD).

Water-resistant
EMC screen
Oil-resistant
Approved
Order designation
Type P-331HF Fire-Resistant 3×16+1G16 mm²
Outer Ø ≈
22.4 mm
Net weight ≈
920 kg/km
Tensile rating ≈
18.5 kN
Core / stranding
IEC 60228 Class 2/5 Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV – 15 kV
Tested per IEEE 1580 / IEC 60331-21 Type
Operating temp.
−40…+125 °C
Continuous subsea & offshore service
Min. bend radius
8 × OD
Winch sheave, chute & seabed routing
Core / conductor
High-Flex Tinned
Stranded tinned copper conductors for po
Outer protection
SHF2 Low-Smoke Z
Thermoset halogen-free oil- and mud-resi
Standard
IEEE 1580 / IEC
IEEE 1580 Type P-331HF & IEC 60331-21 Fi

Typical values for this cable type, based on IEEE 1580 Type P-331HF & IEC 60331-21 Fire-Resistant SHF2 Bronze-Armoured Offshore Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is Type P-331HF Fire-Resistant right for your machine?

IEEE 1580 Type P-331HF & IEC 60331 0.6/1–15 kV Mica-Taped Fire-Resistant SHF2 Offshore Power Cable (IEEE 1580 / IEC 60331-21 Type P-331HF) engineered for 0.6/1 kV – 15 kV service across -40 to +125 °C (min. bend radius 8 × OD).

Fixed installation

Suitable

Mica glass-fibre fire barrier and XLPE/EPR insulation maintain circuit integrity during 750–1,000 °C IEC 60331 fire exposure.

Offshore platform & shipboard deck trays

Suitable

Low-smoke zero-halogen SHF2 sheath and bronze wire braid armour resist oil, drilling fluids and mechanical impact during evacuation.

Drilling jumbo & rotary mast feed

Suitable

IEEE 1580 Type P-331HF and IEC 60331 construction withstands offshore vibration, cold impact (−40 °C) and hazardous-area duty.

Switchgear & control cabinet wiring

Suitable

Terminates directly into emergency switchboards, fire-pump starters, ESD panels and watertight deck glands.

Motorised monospiral reel

Not suitable

Mica-taped fire-resistant offshore cable is designed for fixed installation, not continuous reeling drums.

Use HVSC Shore Power Reeling Cable
Typical machinesMarine & Offshore CableOffshore Emergency Shutdown (ESD) & Fire PumpsFPSO & Drilling Rig Essential Power CircuitsPassenger Vessel Safe-Return-to-Port SystemsShipboard Fire Alarm, PA/GA & Emergency Lighting

Construction

Layer by layer

Shown: Type P-331HF Fire-Resistant (IEEE 1580 Type P-331HF & IEC 60331-21 Fire-Resistant SHF2 Bronze-Armoured Offshore Specification) featuring high-flex tinned copper conductors, mica fire-barrier tape + xlpo insulation and shf2 low-smoke zero-halogen outer jacket (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1High-Flex Tinned Copper ConductorsStranded tinned copper conductors for power, control & VFD circuits
2Mica Fire-Barrier Tape + XLPO InsulationMica tape + cross-linked polyolefin certified to IEC 60331 fire integrity
3Bronze / Tinned Copper Wire Braid ArmourHigh-coverage metallic braid over halogen-free inner bedding
4SHF2 Low-Smoke Zero-Halogen Outer JacketThermoset halogen-free oil- and mud-resistant safety sheath

Type P-331HF Fire-Resistant — Standard Subsea & Offshore Execution

Built to IEEE 1580 Type P-331HF & IEC 60331-21 Fire-Resistant SHF2 Bronze-Armoured Offshore Specification with high-flex tinned copper conductors and shf2 low-smoke zero-halogen outer jacket

Type P-331HF Fire-Resistant — Custom Continuous Winch / Reel Length

Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations

Type P-331HF Fire-Resistant — Hydrostatic, Tensile & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEEE 1580 Type P-331HF & IEC 60331-21 Fire-Resistant SHF2 Bronze-Armoured Offshore Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV – 15 kV (IEEE 1580 Type P-331HF & IEC 60331-21 Fire-Resistant SHF2 Bronze-Armoured Offshore Specification)
Core / conductor construction
High-Flex Tinned Copper Conductors — Stranded tinned copper conductors for power, control & VFD circuits
Primary dielectric / buffering
Mica Fire-Barrier Tape + XLPO Insulation — Mica tape + cross-linked polyolefin certified to IEC 60331 fire integrity

Thermal

Continuous operating temperature
−40…+125 °C (subsea & offshore duty)
Hydrostatic & thermal stability
Verified thermal and hydrostatic stability per IEEE 1580 Type P-331HF & IEC 60331-21 Fire-Resistant SHF2 Bronze-Armoured Offshore Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel winch reel

Mechanical

Outer protection / armouring
SHF2 Low-Smoke Zero-Halogen Outer Jacket — Thermoset halogen-free oil- and mud-resistant safety sheath
Minimum bending radius
8 × OD
Armour, strength member & mechanical duty
Bronze / Tinned Copper Wire Braid Armour — High-coverage metallic braid over halogen-free inner bedding

Resistance

Seawater, hydrostatic & hydrolysis resistance
Engineered for continuous seawater immersion, pressure cycling and hydrolysis resistance per IEEE 1580 Type P-331HF & IEC 60331-21 Fire-Resistant SHF2 Bronze-Armoured Offshore Specification
Oil, drilling mud & abrasion resistance
Resistant to marine hydraulic oils, salt mist, winch sheave wear and seabed abrasion per IEEE 1580 Type P-331HF & IEC 60331-21 Fire-Resistant SHF2 Bronze-Armoured Offshore Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
IEEE 1580 Type P-331HF & IEC 60331-21 Fire-Resistant SHF2 Bronze-Armoured Offshore Specification
Environmental & test standards
IEC 60228 / IEC 60794 / ITU-T G.972 / IEEE 1580 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
Type P-331HF Fire-Resistant
Sheath colour & metre marking
Continuous metre-marked black outer finish (SHF2 Low-Smoke Z)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard Type P-331HF Fire-Resistant subsea & offshore configurations

Manufactured to IEEE 1580 Type P-331HF & IEC 60331-21 Fire-Resistant SHF2 Bronze-Armoured Offshore Specification for subsea, oceanographic, ROV, seismic and offshore applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Breaking / tensile
kN ≈
Min. bend R
mm
Enquiry
Type P-331HF Fire-Resistant Construction Schedule (−40…+125 °C)
Type P-331HF Fire-Resistant 3×16+1G16 mm²3 × 16 + 1G16 mm² (or 1C×50 mm²)IEC 60228 Class 2/5 Cu/SnCu22.492018.5135
Type P-331HF Fire-Resistant 3×35+1G16 mm²3 × 35 + 1G16 mm² (or 1C×150 mm²)IEC 60228 Class 2/5 Cu/SnCu28.81,69032.0175
Type P-331HF Fire-Resistant 3×95+1G50 mm²3 × 95 + 1G50 mm² (or 1C×300 mm²)IEC 60228 Class 2/5 Cu/SnCu41.23,68058.0250
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour breaking loads and continuous winch/seabed lengths available per IEEE 1580 Type P-331HF & IEC 60331-21 Fire-Resistant SHF2 Bronze-Armoured Offshore Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, optical OTDR continuity & dimensional verification (IEEE 1580 Type P-331HF & IEC 60331-21 Fire-Resistant SHF2 Bronze-Armoured Offshore Specification)DC resistance at 20 °C / optical attenuation and outer diameter within IEEE 1580 Type P-331HF & IEC 60331-21 Fire-Resistant SHF2 Bronze-Armoured Offshore Specification tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (IEEE 1580 Type P-331HF & IEC 60331-21 Fire-Resistant SHF2 Bronze-Armoured Offshore Specification)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV – 15 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile breaking load & water-blocking qualification (IEEE 1580 Type P-331HF & IEC 60331-21 Fire-Resistant SHF2 Bronze-Armoured Offshore Specification)Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −40…+125 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEEE 1580 / IEC 60331-21 Type P-331HF CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX Type P-331HF Fire-Resistant IEEE 1580 / IEC 60331-21 Type P-331HF 0.6/1 kV – 15 kV CE
Delivery form
Heavy-duty export fumigated wooden drums, steel oceanographic winch reels or submarine turntables
Standard lengths
500 m, 1,000 m, 3,000 m, 6,000 m or custom continuous subsea lengths
MOQ
100 m (standard configurations) · 500 m (custom subsea builds)
Lead time
2–6 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-26
Updated
2026-10-26

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define Type P-331HF Fire-Resistant (IEEE 1580 Type P-331HF & IEC 60331 0.6/1–15 kV Mica-Taped Fire-Resistant SHF2 Offshore Power Cable)?
Type P-331HF Fire-Resistant (IEEE 1580 Type P-331HF & IEC 60331 0.6/1–15 kV Mica-Taped Fire-Resistant SHF2 Offshore Power Cable) is manufactured in accordance with IEEE 1580 Type P-331HF & IEC 60331-21 Fire-Resistant SHF2 Bronze-Armoured Offshore Specification for 0.6/1 kV – 15 kV service over -40 to +125 °C. Its 4-layer construction comprises high-flex tinned copper conductors, mica fire-barrier tape + xlpo insulation and shf2 low-smoke zero-halogen outer jacket.
What is the minimum bending radius and operating temperature range for Type P-331HF Fire-Resistant?
The minimum bending radius for Type P-331HF Fire-Resistant is 8 × OD across its continuous operating temperature range of -40 to +125 °C, ensuring mechanical, hydrostatic and dielectric reliability in subsea and offshore service.
How are the concentric layers of Type P-331HF Fire-Resistant arranged from inside to outside?
From inside to outside, the construction sequence is: (01) High-Flex Tinned Copper Conductors — Stranded tinned copper conductors for power, control & VFD circuits; (02) Mica Fire-Barrier Tape + XLPO Insulation — Mica tape + cross-linked polyolefin certified to IEC 60331 fire integrity; (03) Bronze / Tinned Copper Wire Braid Armour — High-coverage metallic braid over halogen-free inner bedding; (04) SHF2 Low-Smoke Zero-Halogen Outer Jacket — Thermoset halogen-free oil- and mud-resistant safety sheath.
What factory test certificates are supplied with Type P-331HF Fire-Resistant?
Every production drum of Type P-331HF Fire-Resistant undergoes routine conductor resistance/OTDR continuity, high-voltage dielectric and dimensional testing per IEEE 1580 Type P-331HF & IEC 60331-21 Fire-Resistant SHF2 Bronze-Armoured Offshore Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for Type P-331HF Fire-Resistant

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

IEEE 1580 Type P-331HF & IEC 60331 0.6/1–15 kV Mica-Taped Fire-Resistant SHF2 Offshore Power Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote