Contact

6242Y / 6242B Flat Twin & Earth 300/500V BS 6004 / BS 72116242Y / 6242B Flat Twin & Earth 300/500V BS 6004 / BS 7211 manufactured to BS 6004 / BS 7211, rated 300/500 V and -15°C to +70°C with a 12 × OD minimum bending radius for infrastructure & construction installations.

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Flame-retardant
Oil-resistant
Approved
Order designation
6242Y / 6242B Flat Twin & Earth 300/500V BS (2×2.5 mm²)
Outer diameter
16.5 mm
Cable weight
640 kg/km
Min. bend radius
198 mm
Conductor & shield
Class 1 Solid Plain Copper
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300/500 V
BS 6004 / BS 7211
Temperature
-15°C to +70°C
Fixed / flex duty
Min. bend radius
12 × OD
16.5–22.8 mm
Screening
Unshielded
Fixed / flex duty
Outer sheath
LSZH Jacket
Halogen-free fire-safety corridors
Core / size range
3 sizes
3 standard configurations

Typical values for this cable type, based on Reference specification per BS 6004 / BS 7211 (6242Y / 6242B Flat Twin & Earth 300/500V BS) — confirmed in the datasheet and quotation for your order.

Application fit

Is 6242Y / 6242B Flat Twin & Earth 300/500V BS right for your machine?

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Fixed installation

Suitable

Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.

Motor stator, traction & converter leads

Suitable

Flexible stranded conductors withstand equipment vibration, mobile hook-ups and routine flexing.

Energy chain / drag chain

With conditions

Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.

TBM gantry & advancing tunnel reel

Suitable

Low-smoke zero-halogen outer sheath minimizes toxic acid gas emission and smoke obscuration in fire events.

Vertical / spreader reel

Not suitable

Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.

Use TRA 0.6/1 kV PUR Reeling Cable

Dual-tier power & PLC tray

Suitable

Screened 300/500 V LSZH/PVC construction suppresses electromagnetic interference on shared industrial power and PLC signal trays.

Typical machinesBuilding & Fire SafetyPower distribution & utility networksRailways, tunnels & public infrastructureProcess instrumentation & oil/gas skidsIndustrial automation & control cabinetsRenewable energy, marine & heavy industry

Construction

Layer by layer

Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

6242Y / 6242B Flat Twin & Earth 300/500V BS – Layered cable cutaway
Layer cutaway
#LayerMaterial & reference
1Conductor2×2.5 mm² Class 1 Solid Cu (Brown, Blue) + 1×1.5 mm² Bare Copper CPC (Center)
2Insulation & Core IdentificationBS 6004 / BS 7211 Brown & Blue core insulation + central bare copper CPC
3Screen / Bedding / Armour LayerCentral uninsulated 1×1.5 mm² Class 1 solid bare copper Circuit Protective Conductor (CPC) in flat parallel lay-up
4Outer Protective SheathFlat Grey PVC / White LSZH outer sheath (5.4 × 10.5 mm)

2×2.5 mm²

Class 1 Solid Plain Copper · Outer diameter 16.5 mm

2×4 mm²

Class 1 Solid Plain Copper · Outer diameter 19.5 mm

2×6 mm²

Class 1 Solid Plain Copper · Outer diameter 22.8 mm

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on Reference specification per BS 6004 / BS 7211 (6242Y / 6242B Flat Twin & Earth 300/500V BS). Values for your order are confirmed in the datasheet and quotation.

Electrical

Nominal / reference voltage
300/500 V
Conductor & core insulation
2×2.5 mm² Class 1 Solid Cu (Brown, Blue) + 1×1.5 mm² Bare Copper CPC (Center) · BS 6004 / BS 7211 Brown & Blue core insulation + central bare copper CPC
Routine dielectric / continuity test
100% factory drum spark & continuity verified

Thermal

Operating temperature range
-15°C to +70°C
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s conductor thermal limit)
Flame & fire performance
BS 6004 / BS 7211

Mechanical

Minimum bending radius
12 × OD
Screening / armour architecture
Central uninsulated 1×1.5 mm² Class 1 solid bare copper Circuit Protective Conductor (CPC) in flat parallel lay-up
Outer sheath material & colour
Flat Grey PVC / White LSZH outer sheath (5.4 × 10.5 mm)

Reference standards

Reference standard
BS 6004 / BS 7211
Hazardous Substance Compliance
CE, UKCA, RoHS 2 (2011/65/EU) & REACH SVHC compliant
Quality & Batch Traceability
EN 10204 3.1 Factory Inspection Certificate

Sizes

Sizes & engineering data

Representative configurations from the series specification; select a row to prefill the quotation tool.

All sizes
ConfigurationConductor & shieldInsulation / wallOuter sheathOuter diameter
mm
Min. bend radius
mm
Max. conductor resistance @ 20 °C
Ω/km
Copper weight
kg/km
Cable weight
kg/km
Key electrical / optical ratingPart designationEnquiry
6242Y / 6242B Flat Twin & Earth 300/500V BS
2×2.5 mm²Class 1 Solid Plain CopperBS 6004 / BS 7211 Brown & Blue core insulation + centralLSZH Jacket16.51987.24332.864025 A6242Y / 6242B Flat Twin & Earth 300/500V BS (2×2.5 mm²)
2×4 mm²Class 1 Solid Plain CopperBS 6004 / BS 7211 Brown & Blue core insulation + centralLSZH Jacket19.52344.53463.389134 A6242Y / 6242B Flat Twin & Earth 300/500V BS (2×4 mm²)
2×6 mm²Class 1 Solid Plain CopperBS 6004 / BS 7211 Brown & Blue core insulation + centralLSZH Jacket22.82743.02633.41,21843 A6242Y / 6242B Flat Twin & Earth 300/500V BS (2×6 mm²)
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Dimensions and weights are nominal manufacturing targets subject to standard production tolerances.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance & continuityWithin maximum Ω/km limit at 20 °C per IEC 60228 / BS EN 60228Every manufactured drum length
Dielectric withstand / spark testNo breakdown across insulation, screen or armourEvery manufactured drum length
Sample tests
Vertical flame propagation & jacket qualificationSelf-extinguishing and compliant with reference standard limitsType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

BS 6004 / BS 7211 CompliantEN 10204 3.1 Factory Test CertificateCE, UKCA, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

6242Y / 6242B FLAT TWIN & EARTH 300/500V BS 6004 / BS 7211 / TEBAOFLEX.COM — sequential metre marking
Delivery form
Heavy-duty export fumigated wooden drums or steel reels with moisture-sealed ends
Standard lengths
250 m, 500 m, 1000 m continuous drum lengths or custom cut-to-length runs
MOQ
100 m (standard configurations) · 300 m (custom builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-04
Updated
2026-11-04

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is 6242Y / 6242B Flat Twin & Earth 300/500V BS designed for?
6242Y / 6242B Flat Twin & Earth 300/500V BS is engineered for infrastructure & construction installations under BS 6004 / BS 7211, operating over -15°C to +70°C with a minimum bending radius of 12 × OD.
How is 6242Y / 6242B Flat Twin & Earth 300/500V BS constructed across its layers?
Its 4-layer architecture combines 2×2.5 mm² Class 1 Solid Cu (Brown, Blue) + 1×1.5 mm² Bare Copper CPC (Center) with BS 6004 / BS 7211 Brown & Blue core insulation + central bare copper CPC, Central uninsulated 1×1.5 mm² Class 1 solid bare copper Circuit Protective Conductor (CPC) in flat parallel lay-up and Flat Grey PVC / White LSZH outer sheath (5.4 × 10.5 mm).
What standards and routine factory tests apply to 6242Y / 6242B Flat Twin & Earth 300/500V BS?
Every manufactured drum is tested to BS 6004 / BS 7211 for conductor continuity, dielectric voltage withstand and sheath integrity, supplied with an EN 10204 3.1 inspection certificate.
What sizes and drum lengths are available for 6242Y / 6242B Flat Twin & Earth 300/500V BS?
Representative sizes include 2×2.5 mm², 2×4 mm² and 2×6 mm², supplied on 250 m, 500 m or 1,000 m export drums or custom cut lengths.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for 6242Y / 6242B Flat Twin & Earth 300/500V BS

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

6242Y / 6242B Flat Twin & Earth 300/500V BS 6004 / BS 7211

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote