Fixed installation
Individually and/or collectively screened pairs, triads and quads reject electrostatic and electromagnetic interference.
Product
CMS1S / CMT1S / CMU1S 250 V BS 7917 UKOOA Fire-Resistant Offshore Instrumentation Cable (BS 7917 / UKOOA) engineered for 150/250 V service across -40 to +90 °C (min. bend radius 8 × OD).
Typical values for this cable type, based on BS 7917:1999 & UKOOA Code CMS1S / CMT1S / CMU1S (GL/GM Series) — confirmed in the datasheet and quotation for your order.
Application fit
CMS1S / CMT1S / CMU1S 250 V BS 7917 UKOOA Fire-Resistant Offshore Instrumentation Cable (BS 7917 / UKOOA) engineered for 150/250 V service across -40 to +90 °C (min. bend radius 8 × OD).
Individually and/or collectively screened pairs, triads and quads reject electrostatic and electromagnetic interference.
SHF1/SHF2 or IEEE 1580 Type P outer sheath resists drilling mud, hydrocarbons, salt spray and UV exposure.
Compact twisted pairs and numbered cores route cleanly into DCS/PLC cabinets, Ex-i barriers and bridge consoles.
Tinned copper, bronze or galvanized steel wire braid armour protects signal integrity in hazardous offshore zones.
Fixed shipboard and offshore instrumentation cable is not intended for high-speed crane festoon loops.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: CMS1S / CMT1S / CMU1S 250 V (BS 7917 UKOOA) (BS 7917:1999 & UKOOA Code CMS1S / CMT1S / CMU1S (GL/GM Series)) featuring mica + gp4 epr triads (3×3×1.0 mm²), individual & collective foil screen (mt) and orange type sw4 fire-safe jacket (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Mica + GP4 EPR Triads (3×3×1.0 mm²) | Tinned copper conductors with mica fire tape and Black, White, Red EPR |
| 2 | Individual & Collective Foil Screen (MT) | Al/PET foil tape + tinned copper drain wire on each triad and overall |
| 3 | Type SW4 Inner Sheath & GSWB Armour | Halogen-free SW4 bedding + galvanized steel wire braid armour |
| 4 | Orange Type SW4 Fire-Safe Jacket | BS 7917 950 °C / 3h fire-resistant offshore instrumentation sheath |
Built to BS 7917:1999 & UKOOA Code CMS1S / CMT1S / CMU1S (GL/GM Series) with mica + gp4 epr triads (3×3×1.0 mm²) and orange type sw4 fire-safe jacket
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to BS 7917:1999 & UKOOA Code CMS1S / CMT1S / CMU1S (GL/GM Series) for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| CMS1S / CMT1S / CMU1S 250 V (BS 7917 UKOOA) Construction Schedule (−40…+90 °C) | |||||||
| CMS1S 2×2×0.75 mm² | 2 × 2 × 0.75 mm² (2Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 11.4 | 195 | 1.2 | 70 | |
| CMS1S 4×2×1.0 mm² | 4 × 2 × 1.0 mm² (4Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 15.6 | 365 | 2.4 | 95 | |
| CMS1S 8×2×1.5 mm² | 8 × 2 × 1.5 mm² (8Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 22.8 | 760 | 4.8 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 2 × 2 × 0.75 mm² (2Pr) | 26.00 | 150/250 V (≤60 nF/km) | −40…+90 °C |
| 4 × 2 × 1.0 mm² (4Pr) | 19.50 | 150/250 V (≤65 nF/km) | −40…+90 °C |
| 8 × 2 × 1.5 mm² (8Pr) | 13.30 | 150/250 V (≤75 nF/km) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (BS 7917:1999 & UKOOA Code CMS1S / CMT1S / CMU1S (GL/GM Series)) | DC resistance at 20 °C / optical attenuation and outer diameter within BS 7917:1999 & UKOOA Code CMS1S / CMT1S / CMU1S (GL/GM Series) tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (BS 7917:1999 & UKOOA Code CMS1S / CMT1S / CMU1S (GL/GM Series)) | Zero dielectric breakdown and verified insulation resistance for 150/250 V rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (BS 7917:1999 & UKOOA Code CMS1S / CMT1S / CMU1S (GL/GM Series)) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking