Fixed installation
Mica glass-fibre fire barrier or ceramifying silicone insulation maintains circuit integrity during 750–1,100 °C fire exposure.
Product
MBS1S / MBU1S & YD Series 0.6/1 kV (BS 7917 / UKOOA Code) Mica-Glass-Tape & GP4 EPR-Insulated GSWB-Armoured Type SW4 LSZH Fire-Resistant (IEC 60331) Offshore Power & Control Cable (BS 7917 / BS 6387 CWZ, 0.6/1 kV, -40 to +90 °C).
Typical values for this cable type, based on BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S — confirmed in the datasheet and quotation for your order.
Application fit
MBS1S / MBU1S & YD Series 0.6/1 kV (BS 7917 / UKOOA Code) Mica-Glass-Tape & GP4 EPR-Insulated GSWB-Armoured Type SW4 LSZH Fire-Resistant (IEC 60331) Offshore Power & Control Cable (BS 7917 / BS 6387 CWZ, 0.6/1 kV, -40 to +90 °C).
Mica glass-fibre fire barrier or ceramifying silicone insulation maintains circuit integrity during 750–1,100 °C fire exposure.
Low-smoke zero-halogen SHF1/SHF2/SW4 sheath minimizes toxic gas and smoke opacity during marine evacuation.
Metallic wire braid armour resists mechanical shock, water spray (+WSR) and water jet (+WJR) firefighting impact.
Terminates directly into emergency switchboards, fire-alarm panels, PA/GA systems and watertight glands.
Mica-taped fire-resistant shipboard cable is designed for fixed installation, not continuous reeling drums.
Use HVSC Shore Power Reeling CableConstruction
Shown: MBS1S / MBU1S & YD 0.6/1 KV (BS 7917 UKOOA) (BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S) featuring tinned copper conductors (4×16 mm²), mica tape + gp4 epr insulation (m) and orange type sw4 fire-safe jacket (1s) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Tinned Copper Conductors (4×16 mm²) | BS EN 60228 Class 2 tinned annealed stranded copper conductors |
| 2 | Mica Tape + GP4 EPR Insulation (M) | Mica fire barrier + EPR rated for 950 °C / 3h circuit integrity (BS 6387 CWZ) |
| 3 | Type SW4 Inner Sheath (B) | Extruded low-smoke zero-halogen oil-resistant elastomeric bedding |
| 4 | Galvanized Steel Wire Braid (S - GSWB) | High-coverage galvanized steel wire braid mechanical armour |
| 5 | Orange Type SW4 Fire-Safe Jacket (1S) | Orange BS 7917 SW4 outer sheath for offshore emergency power |
Built to BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S with tinned copper conductors (4×16 mm²) and orange type sw4 fire-safe jacket (1s)
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| MBS1S / MBU1S & YD 0.6/1 KV (BS 7917 UKOOA) Construction Schedule (−40…+90 °C) | |||||||
| MBS1S 3×16+1G16 mm² | 3 × 16 + 1G16 mm² (4G16) | IEC 60228 Class 2/5 Cu/SnCu | 22.4 | 920 | 3.8 | 135 | |
| MBS1S 3×35+1G16 mm² | 3 × 35 + 1G16 mm² (4G35) | IEC 60228 Class 2/5 Cu/SnCu | 28.8 | 1,690 | 7.4 | 175 | |
| MBS1S 3×70+1G35 mm² | 3 × 70 + 1G35 mm² (4G70) | IEC 60228 Class 2/5 Cu/SnCu | 38.2 | 3,260 | 14.8 | 230 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 16 + 1G16 mm² (4G16) | 1.15 | 0.6/1 kV (98 A) | −40…+90 °C |
| 3 × 35 + 1G16 mm² (4G35) | 0.52 | 0.6/1 kV (158 A) | −40…+90 °C |
| 3 × 70 + 1G35 mm² (4G70) | 0.27 | 0.6/1 kV (245 A) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S) | DC resistance at 20 °C / optical attenuation and outer diameter within BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.