fire-resistant shipboard & offshore cableBS 7917 / BS 6387 CWZ0.6/1 kV (-40 to +90 °C)Orange Type SW4 Fire-Safe Jacket (1S

MBS1S / MBU1S & YD Series 0.6/1 kV BS 7917 UKOOA Fire-Resistant Offshore Power CableBS 7917 / BS 6387 CWZ — 0.6/1 kV — -40 to +90 °C Marine & Offshore Cable

MBS1S / MBU1S & YD Series 0.6/1 kV (BS 7917 / UKOOA Code) Mica-Glass-Tape & GP4 EPR-Insulated GSWB-Armoured Type SW4 LSZH Fire-Resistant (IEC 60331) Offshore Power & Control Cable (BS 7917 / BS 6387 CWZ, 0.6/1 kV, -40 to +90 °C).

Flame-retardant
Ozone, UV & moisture
Oil-resistant
Approved
Order designation
MBS1S 3×16+1G16 mm²
Outer Ø ≈
22.4 mm
Net weight ≈
920 kg/km
Tensile rating ≈
3.8 kN
Core / stranding
IEC 60228 Class 2/5 Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per BS 7917 / BS 6387 CWZ
Operating temp.
−40…+90 °C
Continuous shipboard & offshore service
Min. bend radius
8 × OD
Marine tray, bulkhead & deck routing
Core / conductor
Tinned Copper Co
BS EN 60228 Class 2 tinned annealed stra
Outer protection
Orange Type SW4
Orange BS 7917 SW4 outer sheath for offs
Standard
BS 7917 / BS 638
BS 7917:1999 & BS 6387 Cat. C, W, Z / UK

Typical values for this cable type, based on BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S — confirmed in the datasheet and quotation for your order.

Application fit

Is MBS1S / MBU1S & YD 0.6/1 KV (BS 7917 UKOOA) right for your machine?

MBS1S / MBU1S & YD Series 0.6/1 kV (BS 7917 / UKOOA Code) Mica-Glass-Tape & GP4 EPR-Insulated GSWB-Armoured Type SW4 LSZH Fire-Resistant (IEC 60331) Offshore Power & Control Cable (BS 7917 / BS 6387 CWZ, 0.6/1 kV, -40 to +90 °C).

Fixed installation

Suitable

Mica glass-fibre fire barrier or ceramifying silicone insulation maintains circuit integrity during 750–1,100 °C fire exposure.

Offshore platform & shipboard deck trays

Suitable

Low-smoke zero-halogen SHF1/SHF2/SW4 sheath minimizes toxic gas and smoke opacity during marine evacuation.

Drilling jumbo & rotary mast feed

Suitable

Metallic wire braid armour resists mechanical shock, water spray (+WSR) and water jet (+WJR) firefighting impact.

Switchgear & control cabinet wiring

Suitable

Terminates directly into emergency switchboards, fire-alarm panels, PA/GA systems and watertight glands.

Motorised monospiral reel

Not suitable

Mica-taped fire-resistant shipboard cable is designed for fixed installation, not continuous reeling drums.

Use HVSC Shore Power Reeling Cable
Typical machinesBuilding & Fire SafetyOffshore Emergency Shutdown (ESD) & DelugePassenger Cruise & Ferry Safe-Return-to-PortShipboard Fire Alarm, PA/GA & Emergency LightingFPSO & Petrochemical Hydrocarbon Fire Zones

Construction

Layer by layer

Shown: MBS1S / MBU1S & YD 0.6/1 KV (BS 7917 UKOOA) (BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S) featuring tinned copper conductors (4×16 mm²), mica tape + gp4 epr insulation (m) and orange type sw4 fire-safe jacket (1s) (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Tinned Copper Conductors (4×16 mm²)BS EN 60228 Class 2 tinned annealed stranded copper conductors
2Mica Tape + GP4 EPR Insulation (M)Mica fire barrier + EPR rated for 950 °C / 3h circuit integrity (BS 6387 CWZ)
3Type SW4 Inner Sheath (B)Extruded low-smoke zero-halogen oil-resistant elastomeric bedding
4Galvanized Steel Wire Braid (S - GSWB)High-coverage galvanized steel wire braid mechanical armour
5Orange Type SW4 Fire-Safe Jacket (1S)Orange BS 7917 SW4 outer sheath for offshore emergency power

MBS1S / MBU1S & YD 0.6/1 KV (BS 7917 UKOOA) — Standard Shipboard & Offshore Execution

Built to BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S with tinned copper conductors (4×16 mm²) and orange type sw4 fire-safe jacket (1s)

MBS1S / MBU1S & YD 0.6/1 KV (BS 7917 UKOOA) — Custom Drum Length & Gland Kit

Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands

MBS1S / MBU1S & YD 0.6/1 KV (BS 7917 UKOOA) — Class & Routine Test Certified

Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S)
Core / conductor construction
Tinned Copper Conductors (4×16 mm²) — BS EN 60228 Class 2 tinned annealed stranded copper conductors
Primary dielectric / buffering
Mica Tape + GP4 EPR Insulation (M) — Mica fire barrier + EPR rated for 950 °C / 3h circuit integrity (BS 6387 CWZ)

Thermal

Continuous operating temperature
−40…+90 °C (shipboard & offshore duty)
Short-circuit / peak thermal rating
Verified thermal stability per BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Orange Type SW4 Fire-Safe Jacket (1S) — Orange BS 7917 SW4 outer sheath for offshore emergency power
Minimum bending radius
8 × OD
Armour, screen & mechanical duty
Galvanized Steel Wire Braid (S - GSWB) — High-coverage galvanized steel wire braid mechanical armour

Resistance

Flame, fire & smoke performance
Qualified for marine flame-retardance and low-smoke zero-halogen / fire safety per BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S
Oil, drilling mud & seawater resistance
Resistant to marine fuel/lube oils, salt mist and offshore fluids per BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S
Environmental & test standards
IEC 60228 / IEC 60332-3-22 / IEC 60754 / IEC 61034 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
MBS1S / MBU1S & YD 0.6/1 KV (BS 7917 UKOOA)
Sheath colour & metre marking
Continuous metre-marked black outer finish (Orange Type SW4 )
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard MBS1S / MBU1S & YD 0.6/1 KV (BS 7917 UKOOA) shipboard & offshore configurations

Manufactured to BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S for shipboard, offshore platform, drilling rig and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
MBS1S / MBU1S & YD 0.6/1 KV (BS 7917 UKOOA) Construction Schedule (−40…+90 °C)
MBS1S 3×16+1G16 mm²3 × 16 + 1G16 mm² (4G16)IEC 60228 Class 2/5 Cu/SnCu22.49203.8135
MBS1S 3×35+1G16 mm²3 × 35 + 1G16 mm² (4G35)IEC 60228 Class 2/5 Cu/SnCu28.81,6907.4175
MBS1S 3×70+1G35 mm²3 × 70 + 1G35 mm² (4G70)IEC 60228 Class 2/5 Cu/SnCu38.23,26014.8230
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S)DC resistance at 20 °C / optical attenuation and outer diameter within BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Flame, fire integrity, oil/mud & mechanical qualification (BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S)Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

BS 7917 / BS 6387 CWZ CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX MBS1S / MBU1S & YD 0.6/1 KV (BS 7917 UKOOA) BS 7917 / BS 6387 CWZ 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel marine reels
Standard lengths
500 m, 1,000 m or custom continuous shipboard/offshore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define MBS1S / MBU1S & YD 0.6/1 KV (BS 7917 UKOOA) (MBS1S / MBU1S & YD Series 0.6/1 kV BS 7917 UKOOA Fire-Resistant Offshore Power Cable)?
MBS1S / MBU1S & YD 0.6/1 KV (BS 7917 UKOOA) (MBS1S / MBU1S & YD Series 0.6/1 kV BS 7917 UKOOA Fire-Resistant Offshore Power Cable) is manufactured in accordance with BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S for 0.6/1 kV service over -40 to +90 °C. Its 5-layer construction comprises tinned copper conductors (4×16 mm²), mica tape + gp4 epr insulation (m) and orange type sw4 fire-safe jacket (1s).
What is the minimum bending radius and operating temperature range for MBS1S / MBU1S & YD 0.6/1 KV (BS 7917 UKOOA)?
The minimum bending radius for MBS1S / MBU1S & YD 0.6/1 KV (BS 7917 UKOOA) is 8 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical and dielectric reliability in shipboard and offshore service.
How are the concentric layers of MBS1S / MBU1S & YD 0.6/1 KV (BS 7917 UKOOA) arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Tinned Copper Conductors (4×16 mm²) — BS EN 60228 Class 2 tinned annealed stranded copper conductors; (02) Mica Tape + GP4 EPR Insulation (M) — Mica fire barrier + EPR rated for 950 °C / 3h circuit integrity (BS 6387 CWZ); (03) Type SW4 Inner Sheath (B) — Extruded low-smoke zero-halogen oil-resistant elastomeric bedding; (04) Galvanized Steel Wire Braid (S - GSWB) — High-coverage galvanized steel wire braid mechanical armour; (05) Orange Type SW4 Fire-Safe Jacket (1S) — Orange BS 7917 SW4 outer sheath for offshore emergency power.
What factory test certificates are supplied with MBS1S / MBU1S & YD 0.6/1 KV (BS 7917 UKOOA)?
Every production drum of MBS1S / MBU1S & YD 0.6/1 KV (BS 7917 UKOOA) undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per BS 7917:1999 & BS 6387 Cat. C, W, Z / UKOOA Code MBS1S & MBU1S, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for MBS1S / MBU1S & YD 0.6/1 KV (BS 7917 UKOOA)

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

MBS1S / MBU1S & YD Series 0.6/1 kV BS 7917 UKOOA Fire-Resistant Offshore Power Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote