Mine roadway & tunnel wall hangers
Engineered for underground mining shafts, galleries and tunnel infrastructure per IEC 60331-25 / IEC 60332-3-22 / ATEX M2.
Product
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per IEC 60331-25 / IEC 60332-3-22 / ATEX M2 across -40 to +85 °C.
Typical values for this cable type, based on IEC 60331-25 / IEC 60332-3-22 / ATEX M2 — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per IEC 60331-25 / IEC 60332-3-22 / ATEX M2 across -40 to +85 °C.
Engineered for underground mining shafts, galleries and tunnel infrastructure per IEC 60331-25 / IEC 60332-3-22 / ATEX M2.
Suitable for vertical shaft cleats, gallery messenger hooks and tray routing within 15 × OD.
Supports inclined roadway and vertical mine shaft suspension within rated kN load across -40 to +85 °C.
Not optimized for high-speed overhead crane C-track festoon loops; select a dedicated festoon cable.
NGFLGÖU Flat Rubber Festoon CableConstruction
Shown: DTS STEEL FRNC (N45) (IEC 60331-25 / IEC 60332-3-22 / ATEX M2) featuring dts sensing fibres (2×g50/125 µm), laser-welded stainless-steel tube and atex i m2 frnc outer sheath (ø 3.8 mm) (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | DTS Sensing Fibres (2×G50/125 µm) | Two graded-index multimode high-temperature DTS optical sensing fibres |
| 2 | Laser-Welded Stainless-Steel Tube | Hermetically sealed stainless-steel loose tube protecting the 2 sensing fibres |
| 3 | Direct Steel Wire Armour (960 N/cm) | Steel armour wires stranded directly over steel tube for rapid thermal response |
| 4 | ATEX I M2 FRNC Outer Sheath (Ø 3.8 mm) | Black flame-retardant zero-halogen jacket (IEC 60331-25 fire integrity rated) |
Built to IEC 60331-25 / IEC 60332-3-22 / ATEX M2 with dts sensing fibres (2×g50/125 µm) and atex i m2 frnc outer sheath (ø 3.8 mm)
Available in custom shaft/roadway drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report
Technical data
Sizes
Manufactured to IEC 60331-25 / IEC 60332-3-22 / ATEX M2 for underground mining, open-cast excavation, shaft and heavy industrial systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| DTS STEEL FRNC (N45) Construction Schedule (-40 to +85 °C) | |||||||
| DTS STEEL FRNC (N45) 2×G50/125 µm | 2 × G50/125 µm Multimode | Laser-welded SS FIMT + SWA | 3.8 | 32 | 2.0 | 57 | |
| DTS STEEL FRNC (N45) 4×G50/125 µm | 4 × G50/125 µm Multimode | Laser-welded SS FIMT + SWA | 3.8 | 33 | 2.0 | 57 | |
| DTS STEEL FRNC (N45) 2×MM + 2×SM Hybrid | 2×G50/125 + 2×SM G.652.D | Laser-welded SS FIMT + SWA | 4.0 | 36 | 2.2 | 60 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 2 × G50/125 µm Multimode | 2.50 | ≤2.5 / 0.7 dB/km @ 850/1300 nm | -40 to +85 °C |
| 4 × G50/125 µm Multimode | 2.50 | ≤2.5 / 0.7 dB/km @ 850/1300 nm | -40 to +85 °C |
| 2×G50/125 + 2×SM G.652.D | 0.36 | IEC 60331-25 750 °C (90 min) | -40 to +85 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEC 60331-25 / IEC 60332-3-22 / ATEX M2) | DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60331-25 / IEC 60332-3-22 / ATEX M2 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEC 60331-25 / IEC 60332-3-22 / ATEX M2) | Zero dielectric breakdown and verified insulation resistance over full production length | Every manufactured drum length |
| Sample tests | ||
| Flame propagation, mechanical crush & thermal ageing qualification (IEC 60331-25 / IEC 60332-3-22 / ATEX M2) | Verified flame retardancy, mechanical integrity and thermal endurance across -40 to +85 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.