Fixed installation
Stable 300 V LSZH construction routes cleanly in stationary conduits, raceways, ducts, and equipment bays.
Product
LIHH FE180 300 V combines flexible tinned copper cores, ceramifying silicone fire-barrier insulation, and an orange halogen-free LSZH outer sheath to maintain 180-minute fire-alarm and building-safety signaling.
Typical values for this cable type, based on IEC 60331-21 (FE180) · DIN VDE 0812 · IEC 60754-1/2 — confirmed in the datasheet and quotation for your order.
Application fit
LIHH FE180 300 V combines flexible tinned copper cores, ceramifying silicone fire-barrier insulation, and an orange halogen-free LSZH outer sheath to maintain 180-minute fire-alarm and building-safety signaling.
Stable 300 V LSZH construction routes cleanly in stationary conduits, raceways, ducts, and equipment bays.
Thermal-rated 300 V LSZH insulation maintains dielectric safety across continuous high-temperature zones up to +90 °C.
Circuit-integrity 300 V LSZH design sustains emergency alarms, smoke extraction, and evacuation lighting during fire exposure.
Compact flame-retardant 300 V LSZH geometry routes neatly through dense switchgear ducts, control cabinets, and DIN-rail terminals.
300 V LSZH construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR300 V LSZH build lacks anti-torsion tensile reinforcement for motorised drum reeling; select a dedicated reeling cable.
Use RG / RG-D (N)SHTOEU-JConstruction
Representative construction of LIHH FE180 300 V: IEC 60228 Class 5 flexible tinned annealed copper, Ceramifying halogen-free fire-barrier silicone insulation, and Safety-orange flame-retardant halogen-free LSZH outer sheath.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | IEC 60228 Class 5 flexible tinned annealed copperIEC 60228 Class 5 |
| 2 | Dielectric / core insulation | Ceramifying halogen-free fire-barrier silicone insulationIEC 60331-21 (FE180) |
| 3 | Core assembly & separator | Concentric cabled core assembly with low-friction fleece/polyester separator tapeIEC 60331-21 (FE180) |
| 4 | Outer sheath | Safety-orange flame-retardant halogen-free LSZH outer sheath180 min Fire Circuit |
Colour-coded or numbered flexible conductors assembled concentrically inside protective outer sheath.
Technical data
Sizes
| Cores × mm² | Outer Ø ≈ mm | Max. R20 Ω/km | Metal index kg/km | Weight ≈ kg/km | Min. bend R 10×D mm |
|---|---|---|---|---|---|
| 2×0.5 mm² | 6.2 | 40.09 | 10 | 49 | 62 |
| 4×0.5 mm² | 7.2 | 40.09 | 19 | 74 | 72 |
| 2×0.75 mm² | 6.6 | 26.73 | 14 | 59 | 66 |
| 4×0.75 mm² | 7.8 | 26.73 | 29 | 97 | 78 |
| 2×1.0 mm² | 7.2 | 20.05 | 19 | 74 | 72 |
| 4×1.0 mm² | 8.4 | 20.05 | 38 | 119 | 84 |
| 2×1.5 mm² | 7.8 | 13.67 | 29 | 97 | 78 |
| 4×1.5 mm² | 9.2 | 13.67 | 58 | 161 | 92 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| High-voltage dielectric spark / withstand test | 2 kV AC without breakdown | Every manufactured drum |
| Conductor DC resistance check | Per IEC 60228 Class 5 at 20 °C | Every reel / drum length |
| Sample tests | ||
| Dimensional, wall thickness & thermal aging | Rated -40 °C to +90 °C continuous | Per production lot |
| Flame, chemical & mechanical qualification | 180 min Fire Circuit · Halogen-Free Low Smoke | Type approval |
Marking & supply
Sheath marking