Fixed installation
Engineered and verified for fixed service in accordance with ICEA S-76-474 / ANSI/ICEA.
Product
ICEA S-76-474 600 V Aluminum XLPE/ACSR Overhead Triplex Service-Drop Cable engineered to ICEA S-76-474 / ANSI/ICEA for 600 V service across -40 °C to +90 °C, featuring stranded aluminum conductor and xlpe core insulation with minimum bending radius 10 × OD.
Typical values for this cable type, based on ICEA S-76-474 / ANSI/ICEA — confirmed in the datasheet and quotation for your order.
Application fit
ICEA S-76-474 600 V Aluminum XLPE/ACSR Overhead Triplex Service-Drop Cable engineered to ICEA S-76-474 / ANSI/ICEA for 600 V service across -40 °C to +90 °C, featuring stranded aluminum conductor and xlpe core insulation with minimum bending radius 10 × OD.
Engineered and verified for fixed service in accordance with ICEA S-76-474 / ANSI/ICEA.
Suitable for switchgear, control panels and equipment terminations within 10 × OD bend radius.
Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.
Not designed for high-speed monospiral crane reeling; select a dedicated reeling cable.
NSHTOU Reeling CableConstruction
Shown: TRIPLEX XLPE SERVICE DROP (ICEA S-76-474 / ANSI/ICEA) with stranded aluminum conductor, xlpe core insulation and xlpe core insulation (2-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded aluminum conductor | High-conductivity aluminum conductor per ICEA S-76-474 / ANSI/ICEAICEA S-76-474 / ANSI/ICEA |
| 2 | XLPE core insulation | Extruded XLPE dielectric (individual core / group layer)ICEA S-76-474 / ANSI/ICEA |
Built to ICEA S-76-474 / ANSI/ICEA with stranded aluminum conductor and xlpe core insulation
Full range of metric mm² and AWG/kcmil conductor sizes per ICEA S-76-474 / ANSI/ICEA
Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate
Technical data
Sizes
Manufactured to ICEA S-76-474 / ANSI/ICEA in standard cross-sections from 50 mm² to 630 mm² (and North American AWG/kcmil code words).
| Order designation | Nominal area | Stranding | Outer Ø ≈ mm | Weight ≈ kg/km | Rated tensile kN ≈ | Min. sheave R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| TRIPLEX XLPE SERVICE DROP Standard Transmission & Distribution Schedule (−40…+90 °C) | |||||||
| TRIPLEX XLPE SERVICE DROP 50 mm² | 50 mm² | 7/3.00 mm | 9.0 | 138 | 14.5 | 180 | |
| TRIPLEX XLPE SERVICE DROP 95 mm² | 95 mm² | 19/2.52 mm | 12.6 | 262 | 28.2 | 252 | |
| TRIPLEX XLPE SERVICE DROP 120 mm² | 120 mm² | 19/2.85 mm | 14.3 | 334 | 36.4 | 286 | |
| TRIPLEX XLPE SERVICE DROP 150 mm² | 150 mm² | 26/2.70 + 7/2.10 | 17.1 | 546 | 53.8 | 342 | |
| TRIPLEX XLPE SERVICE DROP 185 mm² | 185 mm² | 26/3.00 + 7/2.33 | 19.0 | 674 | 65.2 | 380 | |
| TRIPLEX XLPE SERVICE DROP 240 mm² | 240 mm² | 26/3.44 + 7/2.68 | 21.8 | 885 | 84.5 | 436 | |
| TRIPLEX XLPE SERVICE DROP 300 mm² | 300 mm² | 26/3.86 + 7/3.00 | 24.5 | 1,110 | 104.2 | 490 | |
| TRIPLEX XLPE SERVICE DROP 400 mm² | 400 mm² | 54/3.08 + 7/3.08 | 27.7 | 1,432 | 126.0 | 554 | |
| TRIPLEX XLPE SERVICE DROP 500 mm² | 500 mm² | 54/3.44 + 7/3.44 | 31.0 | 1,790 | 156.5 | 620 | |
| TRIPLEX XLPE SERVICE DROP 630 mm² | 630 mm² | 54/3.86 + 19/2.32 | 34.8 | 2,245 | 194.0 | 696 | |
| Nominal area | Max. DC R₂₀ Ω/km | Continuous current A ≈ | Operating temp. |
|---|---|---|---|
| 50 mm² | 0.578 | 210 | −40…+90 °C |
| 95 mm² | 0.304 | 320 | −40…+90 °C |
| 150 mm² | 0.192 | 435 | −40…+90 °C |
| 240 mm² | 0.119 | 590 | −40…+90 °C |
| 400 mm² | 0.072 | 820 | −40…+90 °C |
| 630 mm² | 0.046 | 1,080 | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance & dimensional verification (ICEA S-76-474 / ANSI/ICEA) | DC resistance at 20 °C and geometry within ICEA S-76-474 / ANSI/ICEA class limits | Every manufactured drum / spool |
| Routine dielectric / spark / structural integrity test (ICEA S-76-474 / ANSI/ICEA) | Zero breakdown or structural defect over full production length | Every manufactured drum / spool |
| Sample tests | ||
| Thermal aging, mechanical & material qualification (ICEA S-76-474 / ANSI/ICEA) | Full compliance with ICEA S-76-474 / ANSI/ICEA across −40…+90 °C | Type qualification & periodic sample audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.