Category 6 U/UTP 4×2×23 AWG Gigabit Horizontal LAN CableANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR · 300 V (PoE++ 100 W) · -20 °C to +75 °C

Category 6 U/UTP 4×2×23 AWG Gigabit Horizontal LAN Cable engineered to ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR for 300 V service across -20 °C to +75 °C, featuring stranded copper conductor and pvc outer jacket with minimum bending radius 4 × OD.

Approved
Flame-retardant
Oil-resistant
Order designation
CAT6 U/UTP 23 AWG 4×2×1.0
Outer Ø ≈
13.5 mm
Total weight ≈
264 kg/km
Min. bend R (fixed)
108 mm
Configuration
4×2×1.0 mm²
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300 V (PoE++
Per ANSI/TIA-568.2-D / ISO/IEC 11801
Operating temp.
−20…+75 °C
Continuous thermal rating (ANSI)
Min. bend radius
4 × OD
Installed / fixed routing
Conductor
copper conductor
High-conductivity copper conductor
Outer layer
PVC outer jacket
Extruded PVC outer jacket protective
Standard
ANSI
ANSI/TIA-568.2-D / ISO/IEC 11801 / UL

Typical values for this cable type, based on ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR — confirmed in the datasheet and quotation for your order.

Application fit

Is CAT6 U/UTP 23 AWG right for your machine?

Category 6 U/UTP 4×2×23 AWG Gigabit Horizontal LAN Cable engineered to ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR for 300 V service across -20 °C to +75 °C, featuring stranded copper conductor and pvc outer jacket with minimum bending radius 4 × OD.

Fixed installation

Suitable

Engineered and verified for fixed service in accordance with ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR.

Switchgear & control cabinet wiring

Suitable

Engineered and verified for cabinet chassis service in accordance with ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Motorised monospiral reel

Not suitable

Not designed for high-speed monospiral crane reeling; select a dedicated reeling cable.

NSHTOU Reeling Cable
Typical machinesBuilding & Fire SafetyCommercial & Residential Building DistributionData Centers & Public InfrastructureFire-Safe Evacuation & Riser ShaftsIndustrial Plant Balance-of-Plant WiringAutomated Assembly & Packaging Lines

Construction

Layer by layer

Shown: CAT6 U/UTP 23 AWG (ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR) with stranded copper conductor, polyolefin and pvc outer jacket (3-layer construction).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded copper conductorHigh-conductivity copper conductor per ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMRANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR
2PolyolefinHelically applied polyolefinANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR
3PVC outer jacketExtruded PVC outer jacket protective layer (continuous layer)ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR

CAT6 U/UTP 23 AWG — Standard Execution

Built to ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR with stranded copper conductor and pvc outer jacket

CAT6 U/UTP 23 AWG — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR

CAT6 U/UTP 23 AWG — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
300 V (PoE++ 100 W) (ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR)
Conductor construction
Stranded copper conductor — High-conductivity copper conductor per ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR
Primary insulation / dielectric
Polyolefin — Helically applied polyolefin

Thermal

Continuous operating temperature
−20…+75 °C per ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
PVC outer jacket — Extruded PVC outer jacket protective layer (continuous layer)
Minimum bending radius
4 × OD (installed / static routing)
Layer count & geometry
3 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
CAT6 U/UTP 23 AWG
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

12 standard CAT6 U/UTP 23 AWG cable configurations

Manufactured to ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR in single-pair, multi-pair and multi-unit constructions.

Dimensions, construction & weights
Order designationConfigurationOuter Ø ≈
mm
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
CAT6 U/UTP 23 AWG Standard Construction Schedule (300 V (PoE++ 100 W) · −20…+75 °C)
CAT6 U/UTP 23 AWG 1×2×0.51×2×0.5 mm²6.45852
CAT6 U/UTP 23 AWG 2×2×0.52×2×0.5 mm²9.211274
CAT6 U/UTP 23 AWG 4×2×0.54×2×0.5 mm²11.417692
CAT6 U/UTP 23 AWG 8×2×0.58×2×0.5 mm²14.8295118
CAT6 U/UTP 23 AWG 12×2×0.512×2×0.5 mm²17.6420141
CAT6 U/UTP 23 AWG 1×2×1.01×2×1.0 mm²7.68661
CAT6 U/UTP 23 AWG 2×2×1.02×2×1.0 mm²11.016888
CAT6 U/UTP 23 AWG 4×2×1.04×2×1.0 mm²13.5264108
CAT6 U/UTP 23 AWG 8×2×1.08×2×1.0 mm²17.9465143
CAT6 U/UTP 23 AWG 1×2×1.51×2×1.5 mm²8.511468
CAT6 U/UTP 23 AWG 4×2×1.54×2×1.5 mm²15.2348122
CAT6 U/UTP 23 AWG 12×2×1.512×2×1.5 mm²23.4860187
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Additional pair/triad/quad counts (up to 48 pairs) and blue Ex-i intrinsically safe outer sheaths available per ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR)DC resistance at 20 °C and geometry within ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR)Full compliance with ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR across −20…+75 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

ANSI CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX CAT6 U/UTP 23 AWG <size> ANSI 300 V (PoE++ 100 W) CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define CAT6 U/UTP 23 AWG (Category 6 U/UTP 4×2×23 AWG Gigabit Horizontal LAN Cable)?
CAT6 U/UTP 23 AWG (Category 6 U/UTP 4×2×23 AWG Gigabit Horizontal LAN Cable) is manufactured in accordance with ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR for 300 V (PoE++ 100 W) service over -20 °C to +75 °C. Its 3-layer construction comprises stranded copper conductor, polyolefin, pvc outer jacket.
What is the minimum bending radius and installation temperature for CAT6 U/UTP 23 AWG?
The minimum installed bending radius for CAT6 U/UTP 23 AWG is 4 × OD across its continuous operating temperature range of -20 °C to +75 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of CAT6 U/UTP 23 AWG arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded copper conductor (High-conductivity copper conductor per ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR); (02) Polyolefin (Helically applied polyolefin); (03) PVC outer jacket (Extruded PVC outer jacket protective layer (continuous layer)).
What factory test certificates are supplied with CAT6 U/UTP 23 AWG?
Every production drum or spool of CAT6 U/UTP 23 AWG undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per ANSI/TIA-568.2-D / ISO/IEC 11801 / UL 444 CMR, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for CAT6 U/UTP 23 AWG

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

CAT6 U/UTP 23 AWG Category 6 U/UTP 4×2×23 AWG Gigabit Horizontal LAN Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 