Fixed installation
Mica glass-fibre fire barrier or ceramifying silicone insulation maintains circuit integrity during 750–1,100 °C fire exposure.
Product
BFOU P5/P12/P105 & BFOU-HCF P34 0.6/1(1.2) kV (Type P) Mica/EPR Fire-Resistant TCWB-Armoured SHF2 Mud-Resistant Offshore Power Cable (NEK TS 606 / IEC 60331, 0.6/1 kV, -40 to +90 °C, min. bend radius 8 × OD).
Typical values for this cable type, based on NEK TS 606 Code P5/P12/P105 & P34 / IEC 60331-21 / IEC 60092-353 — confirmed in the datasheet and quotation for your order.
Application fit
BFOU P5/P12/P105 & BFOU-HCF P34 0.6/1(1.2) kV (Type P) Mica/EPR Fire-Resistant TCWB-Armoured SHF2 Mud-Resistant Offshore Power Cable (NEK TS 606 / IEC 60331, 0.6/1 kV, -40 to +90 °C, min. bend radius 8 × OD).
Mica glass-fibre fire barrier or ceramifying silicone insulation maintains circuit integrity during 750–1,100 °C fire exposure.
Low-smoke zero-halogen SHF1/SHF2/SW4 sheath minimizes toxic gas and smoke opacity during marine evacuation.
Metallic wire braid armour resists mechanical shock, water spray (+WSR) and water jet (+WJR) firefighting impact.
Terminates directly into emergency switchboards, fire-alarm panels, PA/GA systems and watertight glands.
Mica-taped fire-resistant shipboard cable is designed for fixed installation, not continuous reeling drums.
Use HVSC Shore Power Reeling CableConstruction
Shown: BFOU P5/P12 & BFOU-HCF P34 0.6/1 KV (NEK TS 606 Code P5/P12/P105 & P34 / IEC 60331-21 / IEC 60092-353) featuring tinned copper conductors (4g25 mm²), mica fire barrier + epr insulation (bf) and shf2-mud outer sheath (u - p5/p12) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Tinned Copper Conductors (4G25 mm²) | IEC 60228 Class 2 / Class 5 stranded tinned copper conductors |
| 2 | Mica Fire Barrier + EPR Insulation (BF) | Mica glass tape + EPR certified to IEC 60331 & 1,100 °C HCF Jet Fire (P34) |
| 3 | Thermoset Fire-Safe Inner Sheath | Halogen-free cross-linked elastomeric inner bedding sheath |
| 4 | Tinned Copper Wire Braid Armour (O) | High-density tinned copper wire braid (TCWB) |
| 5 | SHF2-MUD Outer Sheath (U - P5/P12) | Mud-resistant thermoset jacket for offshore rigs and FPSOs |
Built to NEK TS 606 Code P5/P12/P105 & P34 / IEC 60331-21 / IEC 60092-353 with tinned copper conductors (4g25 mm²) and shf2-mud outer sheath (u - p5/p12)
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to NEK TS 606 Code P5/P12/P105 & P34 / IEC 60331-21 / IEC 60092-353 for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| BFOU P5/P12 & BFOU-HCF P34 0.6/1 KV Construction Schedule (−40…+90 °C) | |||||||
| BFOU P5 3×16+1G16 mm² | 3 × 16 + 1G16 mm² (4G16) | IEC 60228 Class 2/5 Cu/SnCu | 22.4 | 920 | 3.8 | 135 | |
| BFOU P5 3×35+1G16 mm² | 3 × 35 + 1G16 mm² (4G35) | IEC 60228 Class 2/5 Cu/SnCu | 28.8 | 1,690 | 7.4 | 175 | |
| BFOU P5 3×70+1G35 mm² | 3 × 70 + 1G35 mm² (4G70) | IEC 60228 Class 2/5 Cu/SnCu | 38.2 | 3,260 | 14.8 | 230 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 16 + 1G16 mm² (4G16) | 1.15 | 0.6/1 kV (98 A) | −40…+90 °C |
| 3 × 35 + 1G16 mm² (4G35) | 0.52 | 0.6/1 kV (158 A) | −40…+90 °C |
| 3 × 70 + 1G35 mm² (4G70) | 0.27 | 0.6/1 kV (245 A) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (NEK TS 606 Code P5/P12/P105 & P34 / IEC 60331-21 / IEC 60092-353) | DC resistance at 20 °C / optical attenuation and outer diameter within NEK TS 606 Code P5/P12/P105 & P34 / IEC 60331-21 / IEC 60092-353 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (NEK TS 606 Code P5/P12/P105 & P34 / IEC 60331-21 / IEC 60092-353) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (NEK TS 606 Code P5/P12/P105 & P34 / IEC 60331-21 / IEC 60092-353) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking