FDLHEH 1.8/3 kV (0.6/1 kV) Class 5 AA8000 Flexible Aluminum-Alloy EPR / Class-A LSZH Wind Torsion & Tower CableT/CECA 408 / NB/T 31034 — 1.8/3 kV (0.6/1 kV) — -40 to +90 °C Wind Turbine Cable

FDLHEH 1.8/3 kV (0.6/1 kV) Class 5 AA8000 Flexible Aluminum-Alloy EPR / Class-A LSZH Wind Torsion & Tower Cable (T/CECA 408 / NB/T 31034) engineered for 1.8/3 kV (0.6/1 kV) wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).

Anti-torsion braid
Flame-retardant
Oil-resistant
Approved
Order designation
FDLHEH 1.8 1×150 / 4×95 Al
Outer Ø ≈
23.5 mm
Net weight ≈
640 kg/km
Max. pulling ≈
10.5 kN
Core / stranding
Class 2 Compacted Al / Class 5 AA8000
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
1.8/3 kV (0.6/1
Tested per T/CECA 408 / NB/T 31034
Operating temp.
−40…+90 °C
Cold-climate & nacelle wind service
Min. bend radius
6 × OD
Drip-loop, hub & tower routing
Core / conductor
Class 5 AA8000 F
High-creep-resistance flexible aluminum
Outer protection
Class-A LSZH The
IEC 60332-3-22 Cat.A halogen-free elasto
Standard
T/CECA 408 / NB/
T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al

Typical values for this cable type, based on T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is FDLHEH 1.8/3 kV AA8000 Al-Alloy right for your machine?

FDLHEH 1.8/3 kV (0.6/1 kV) Class 5 AA8000 Flexible Aluminum-Alloy EPR / Class-A LSZH Wind Torsion & Tower Cable (T/CECA 408 / NB/T 31034) engineered for 1.8/3 kV (0.6/1 kV) wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).

Free-hanging vertical run

Suitable

Cross-linked EPR/HEPR insulation and 5GM5 / XL-EVA halogen-free jacket withstand ±100°/m to ±180°/m yaw drip-loop torsion at −40 °C.

Fixed installation

Suitable

IEC 60332-3 flame-retardant low-smoke zero-halogen (LSZH) outer sheath routes safely through vertical wind tower ladders and cleats.

Offshore platform & shipboard deck trays

Suitable

Oil-, ozone-, UV- and salt-mist-resistant thermoset EVA/elastomer sheath endures both onshore and offshore wind nacelle environments.

Motor stator, traction & converter leads

Suitable

Finely stranded IEC 60228 Class 5 copper or AA8000 Al-alloy conductors terminate cleanly into generator, converter and transformer lugs.

Motorised monospiral reel

Not suitable

Wind turbine drip-loop torsion and fixed tower cables are not designed for high-speed horizontal crane reeling drums.

Use Spreader Reel Cable
Typical machinesRenewable Energy & EV ChargingOnshore & Offshore Wind Turbine Nacelle Drip LoopsWind Turbine Generator-to-Converter Main Power DropsHalogen-Free Wind Tower Vertical Power DistributionCold-Climate (−40 °C) Renewable Energy Installations

Construction

Layer by layer

Shown: FDLHEH 1.8/3 kV AA8000 Al-Alloy (T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification) featuring class 5 aa8000 flexible al-alloy conductor (code lh), 1.8/3 kv epr elastomeric insulation (code e) and class-a lszh thermoset elastomer sheath (code h) (3-layer construction).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Class 5 AA8000 Flexible Al-Alloy ConductHigh-creep-resistance flexible aluminum alloy (70-400 mm²)
21.8/3 kV EPR Elastomeric Insulation (CodCross-linked ethylene-propylene rubber primary insulation
3Class-A LSZH Thermoset Elastomer Sheath IEC 60332-3-22 Cat.A halogen-free elastomer jacket (-40 °C)

FDLHEH 1.8/3 kV AA8000 Al-Alloy — Standard Wind Turbine Execution

Built to T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification with class 5 aa8000 flexible al-alloy conductor (code lh) and class-a lszh thermoset elastomer sheath (code h)

FDLHEH 1.8/3 kV AA8000 Al-Alloy — Pre-Cut Tower / Drip-Loop Kit

Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths

FDLHEH 1.8/3 kV AA8000 Al-Alloy — Cold Torsion & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
1.8/3 kV (0.6/1 kV) (T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification)
Core / conductor construction
Class 5 AA8000 Flexible Al-Alloy Conductor (Code LH) — High-creep-resistance flexible aluminum alloy (70-400 mm²)
Primary dielectric / insulation
1.8/3 kV EPR Elastomeric Insulation (Code E) — Cross-linked ethylene-propylene rubber primary insulation

Thermal

Continuous operating temperature
−40…+90 °C (wind turbine nacelle, hub & tower duty)
Low-temperature torsion & cold bend
Verified cold-flex and torsion endurance across −40…+90 °C per T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
Class-A LSZH Thermoset Elastomer Sheath (Code H) — IEC 60332-3-22 Cat.A halogen-free elastomer jacket (-40 °C)
Minimum bending radius
6 × OD
Intermediate screen / separator / core layer
1.8/3 kV EPR Elastomeric Insulation (Code E) — Cross-linked ethylene-propylene rubber primary insulation

Resistance

Oil, grease, ozone & UV resistance
Resistant to wind turbine gearbox oil, hydraulic fluid, ozone and UV weathering per T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification
Flame retardancy & smoke/halogen emission
Flame-retardant and environmental performance verified per T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification
Conductor & flame/test standards
IEC 60228 / IEC 60332-1-2 & -3 / UL 2277 WTTC / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
FDLHEH 1.8/3 kV AA8000 Al-Alloy
Sheath colour & metre marking
Continuous metre-marked black outer finish (Class-A LSZH The)
Customs tariff (HS)
8544.49 / 8544.60

Sizes

3 standard FDLHEH 1.8/3 kV AA8000 Al-Alloy wind turbine configurations

Manufactured to T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
FDLHEH 1.8/3 kV AA8000 Al-Alloy Construction Schedule (−40…+90 °C)
FDLHEH 1.8 1×150 / 4×95 Al1 × 150 mm² (or 4 × 95 mm² Al)Class 2 Compacted Al / Class 5 AA800023.564010.5190
FDLHEH 1.8 1×240 / 4×150 Al1 × 240 mm² (or 4 × 150 mm² Al)Class 2 Compacted Al / Class 5 AA800028.498016.8230
FDLHEH 1.8 1×400 / 4×240 Al1 × 400 mm² (or 4 × 240 mm² Al)Class 2 Compacted Al / Class 5 AA800035.81,59028.0290
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom conductor cross-sections, core counts, pre-lugged tower kits and drum lengths available per T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification)DC resistance at 20 °C and insulation/sheath wall thickness within T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification)Zero dielectric breakdown and verified insulation resistance for 1.8/3 kV (0.6/1 kV) ratingEvery manufactured drum length
Sample tests
Low-temperature drip-loop torsion, oil & flame qualification (T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification)Verified cold torsion cycle endurance, oil resistance and flame retardancy across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

T/CECA 408 / NB/T 31034 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX FDLHEH 1.8/3 kV AA8000 Al-Alloy T/CECA 408 / NB/T 31034 1.8/3 kV (0.6/1 kV) CE
Delivery form
Heavy-duty export fumigated wooden drums, steel reels or pre-cut wind turbine tower & drip-loop kits
Standard lengths
500 m, 1,000 m or custom cut-to-length nacelle drip-loop and tower section sets
MOQ
100 m (standard configurations) · 300 m (custom wind builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-27
Updated
2026-10-27

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define FDLHEH 1.8/3 kV AA8000 Al-Alloy (FDLHEH 1.8/3 kV (0.6/1 kV) Class 5 AA8000 Flexible Aluminum-Alloy EPR / Class-A LSZH Wind Torsion & Tower Cable)?
FDLHEH 1.8/3 kV AA8000 Al-Alloy (FDLHEH 1.8/3 kV (0.6/1 kV) Class 5 AA8000 Flexible Aluminum-Alloy EPR / Class-A LSZH Wind Torsion & Tower Cable) is manufactured in accordance with T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification for 1.8/3 kV (0.6/1 kV) wind turbine service over -40 to +90 °C. Its 3-layer construction comprises class 5 aa8000 flexible al-alloy conductor (code lh), 1.8/3 kv epr elastomeric insulation (code e) and class-a lszh thermoset elastomer sheath (code h).
What is the minimum bending radius and operating temperature range for FDLHEH 1.8/3 kV AA8000 Al-Alloy?
The minimum bending radius for FDLHEH 1.8/3 kV AA8000 Al-Alloy is 6 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical torsion resistance and dielectric reliability in wind turbine nacelles, hubs and towers.
How are the concentric layers of FDLHEH 1.8/3 kV AA8000 Al-Alloy arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Class 5 AA8000 Flexible Al-Alloy Conductor (Code LH) — High-creep-resistance flexible aluminum alloy (70-400 mm²); (02) 1.8/3 kV EPR Elastomeric Insulation (Code E) — Cross-linked ethylene-propylene rubber primary insulation; (03) Class-A LSZH Thermoset Elastomer Sheath (Code H) — IEC 60332-3-22 Cat.A halogen-free elastomer jacket (-40 °C).
What factory test certificates are supplied with FDLHEH 1.8/3 kV AA8000 Al-Alloy?
Every production drum of FDLHEH 1.8/3 kV AA8000 Al-Alloy undergoes routine conductor DC resistance, AC high-voltage dielectric and dimensional testing per T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for FDLHEH 1.8/3 kV AA8000 Al-Alloy

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

FDLHEH 1.8/3 kV AA8000 Al-Alloy FDLHEH 1.8/3 kV (0.6/1 kV) Class 5 AA8000 Flexible Aluminum-Alloy EPR / Class-A LSZH Wind Torsion & Tower Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote