Free-hanging vertical run
Cross-linked EPR/HEPR insulation and 5GM5 / XL-EVA halogen-free jacket withstand ±100°/m to ±180°/m yaw drip-loop torsion at −40 °C.
Product
FDLHEH 1.8/3 kV (0.6/1 kV) Class 5 AA8000 Flexible Aluminum-Alloy EPR / Class-A LSZH Wind Torsion & Tower Cable (T/CECA 408 / NB/T 31034) engineered for 1.8/3 kV (0.6/1 kV) wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).
Typical values for this cable type, based on T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification — confirmed in the datasheet and quotation for your order.
Application fit
FDLHEH 1.8/3 kV (0.6/1 kV) Class 5 AA8000 Flexible Aluminum-Alloy EPR / Class-A LSZH Wind Torsion & Tower Cable (T/CECA 408 / NB/T 31034) engineered for 1.8/3 kV (0.6/1 kV) wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).
Cross-linked EPR/HEPR insulation and 5GM5 / XL-EVA halogen-free jacket withstand ±100°/m to ±180°/m yaw drip-loop torsion at −40 °C.
IEC 60332-3 flame-retardant low-smoke zero-halogen (LSZH) outer sheath routes safely through vertical wind tower ladders and cleats.
Oil-, ozone-, UV- and salt-mist-resistant thermoset EVA/elastomer sheath endures both onshore and offshore wind nacelle environments.
Finely stranded IEC 60228 Class 5 copper or AA8000 Al-alloy conductors terminate cleanly into generator, converter and transformer lugs.
Wind turbine drip-loop torsion and fixed tower cables are not designed for high-speed horizontal crane reeling drums.
Use Spreader Reel CableConstruction
Shown: FDLHEH 1.8/3 kV AA8000 Al-Alloy (T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification) featuring class 5 aa8000 flexible al-alloy conductor (code lh), 1.8/3 kv epr elastomeric insulation (code e) and class-a lszh thermoset elastomer sheath (code h) (3-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Class 5 AA8000 Flexible Al-Alloy Conduct | High-creep-resistance flexible aluminum alloy (70-400 mm²) |
| 2 | 1.8/3 kV EPR Elastomeric Insulation (Cod | Cross-linked ethylene-propylene rubber primary insulation |
| 3 | Class-A LSZH Thermoset Elastomer Sheath | IEC 60332-3-22 Cat.A halogen-free elastomer jacket (-40 °C) |
Built to T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification with class 5 aa8000 flexible al-alloy conductor (code lh) and class-a lszh thermoset elastomer sheath (code h)
Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths
Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report
Technical data
Sizes
Manufactured to T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| FDLHEH 1.8/3 kV AA8000 Al-Alloy Construction Schedule (−40…+90 °C) | |||||||
| FDLHEH 1.8 1×150 / 4×95 Al | 1 × 150 mm² (or 4 × 95 mm² Al) | Class 2 Compacted Al / Class 5 AA8000 | 23.5 | 640 | 10.5 | 190 | |
| FDLHEH 1.8 1×240 / 4×150 Al | 1 × 240 mm² (or 4 × 150 mm² Al) | Class 2 Compacted Al / Class 5 AA8000 | 28.4 | 980 | 16.8 | 230 | |
| FDLHEH 1.8 1×400 / 4×240 Al | 1 × 400 mm² (or 4 × 240 mm² Al) | Class 2 Compacted Al / Class 5 AA8000 | 35.8 | 1,590 | 28.0 | 290 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 1 × 150 mm² (or 4 × 95 mm² Al) | 0.21 | 1.8/3 kV (0.6/1 kV) (315 A Al) | −40…+90 °C |
| 1 × 240 mm² (or 4 × 150 mm² Al) | 0.13 | 1.8/3 kV (0.6/1 kV) (435 A Al) | −40…+90 °C |
| 1 × 400 mm² (or 4 × 240 mm² Al) | 0.08 | 1.8/3 kV (0.6/1 kV) (590 A Al) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance & dimensional verification (T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification) | DC resistance at 20 °C and insulation/sheath wall thickness within T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification) | Zero dielectric breakdown and verified insulation resistance for 1.8/3 kV (0.6/1 kV) rating | Every manufactured drum length |
| Sample tests | ||
| Low-temperature drip-loop torsion, oil & flame qualification (T/CECA 408 & NB/T 31034 FDLHEH AA8000 Al-Alloy Cat.A LSZH Wind Torsion Specification) | Verified cold torsion cycle endurance, oil resistance and flame retardancy across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.