halogen-free wind turbine torsion & tower cableIEC 60332-3 / UL 1000V0.6/1 kV / 1,000 V (-40 to +90 °C)FRNC/LSZH Thermoset Outer Sheath (±1

FRNC / LSZH 0.6/1 kV (IEC) & 1,000 V (UL) Halogen-Free Flame-Retardant Wind Drip-Loop Torsion CableIEC 60332-3 / UL 1000V — 0.6/1 kV / 1,000 V — -40 to +90 °C Wind Turbine Cable

FRNC / LSZH 0.6/1 kV (IEC) & 1,000 V (UL) Halogen-Free Flame-Retardant Wind Drip-Loop Torsion Cable (IEC 60332-3 / UL 1000V) engineered for 0.6/1 kV / 1,000 V wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).

Anti-torsion braid
Flame-retardant
Oil-resistant
Approved
Order designation
FRNC 0.6 7G1.5 mm²
Outer Ø ≈
11.4 mm
Net weight ≈
215 kg/km
Max. pulling ≈
2.4 kN
Core / stranding
IEC 60228 Class 5/6 / Class K Cu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV / 1,000
Tested per IEC 60332-3 / UL 1000V
Operating temp.
−40…+90 °C
Cold-climate & nacelle wind service
Min. bend radius
6 × OD
Drip-loop, hub & tower routing
Core / conductor
Class 5 Flexible
Stranded plain copper conductors for con
Outer protection
FRNC/LSZH Thermo
Flame-retardant non-corrosive low-smoke
Standard
IEC 60332-3 / UL
IEC 60332-3-22/24, IEC 60754-2 & UL 1,00

Typical values for this cable type, based on IEC 60332-3-22/24, IEC 60754-2 & UL 1,000 V FRNC/LSZH (±150°/m) Wind Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is FRNC 0.6/1 kV Drip-Loop right for your machine?

FRNC / LSZH 0.6/1 kV (IEC) & 1,000 V (UL) Halogen-Free Flame-Retardant Wind Drip-Loop Torsion Cable (IEC 60332-3 / UL 1000V) engineered for 0.6/1 kV / 1,000 V wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).

Free-hanging vertical run

Suitable

Cross-linked EPR/HEPR insulation and 5GM5 / XL-EVA halogen-free jacket withstand ±100°/m to ±180°/m yaw drip-loop torsion at −40 °C.

Fixed installation

Suitable

IEC 60332-3 flame-retardant low-smoke zero-halogen (LSZH) outer sheath routes safely through vertical wind tower ladders and cleats.

Offshore platform & shipboard deck trays

Suitable

Oil-, ozone-, UV- and salt-mist-resistant thermoset EVA/elastomer sheath endures both onshore and offshore wind nacelle environments.

Motor stator, traction & converter leads

Suitable

Finely stranded IEC 60228 Class 5 copper or AA8000 Al-alloy conductors terminate cleanly into generator, converter and transformer lugs.

Motorised monospiral reel

Not suitable

Wind turbine drip-loop torsion and fixed tower cables are not designed for high-speed horizontal crane reeling drums.

Use Spreader Reel Cable
Typical machinesRenewable Energy & EV ChargingOnshore & Offshore Wind Turbine Nacelle Drip LoopsWind Turbine Generator-to-Converter Main Power DropsHalogen-Free Wind Tower Vertical Power DistributionCold-Climate (−40 °C) Renewable Energy Installations

Construction

Layer by layer

Shown: FRNC 0.6/1 kV Drip-Loop (IEC 60332-3-22/24, IEC 60754-2 & UL 1,000 V FRNC/LSZH (±150°/m) Wind Specification) featuring class 5 flexible bare copper (2-37 cores, 0.5-95 mm²), halogen-free xlpo / epr core insulation and frnc/lszh thermoset outer sheath (±150°/m) (3-layer construction).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Class 5 Flexible Bare Copper (2-37 CoresStranded plain copper conductors for control & auxiliary power
2Halogen-Free XLPO / EPR Core InsulationCross-linked zero-halogen numbered core insulation
3FRNC/LSZH Thermoset Outer Sheath (±150°/Flame-retardant non-corrosive low-smoke elastomer jacket

FRNC 0.6/1 kV Drip-Loop — Standard Wind Turbine Execution

Built to IEC 60332-3-22/24, IEC 60754-2 & UL 1,000 V FRNC/LSZH (±150°/m) Wind Specification with class 5 flexible bare copper (2-37 cores, 0.5-95 mm²) and frnc/lszh thermoset outer sheath (±150°/m)

FRNC 0.6/1 kV Drip-Loop — Pre-Cut Tower / Drip-Loop Kit

Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths

FRNC 0.6/1 kV Drip-Loop — Cold Torsion & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60332-3-22/24, IEC 60754-2 & UL 1,000 V FRNC/LSZH (±150°/m) Wind Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
0.6/1 kV / 1,000 V (IEC 60332-3-22/24, IEC 60754-2 & UL 1,000 V FRNC/LSZH (±150°/m) Wind Specification)
Core / conductor construction
Class 5 Flexible Bare Copper (2-37 Cores, 0.5-95 mm²) — Stranded plain copper conductors for control & auxiliary power
Primary dielectric / insulation
Halogen-Free XLPO / EPR Core Insulation — Cross-linked zero-halogen numbered core insulation

Thermal

Continuous operating temperature
−40…+90 °C (wind turbine nacelle, hub & tower duty)
Low-temperature torsion & cold bend
Verified cold-flex and torsion endurance across −40…+90 °C per IEC 60332-3-22/24, IEC 60754-2 & UL 1,000 V FRNC/LSZH (±150°/m) Wind Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
FRNC/LSZH Thermoset Outer Sheath (±150°/m) — Flame-retardant non-corrosive low-smoke elastomer jacket
Minimum bending radius
6 × OD
Intermediate screen / separator / core layer
Halogen-Free XLPO / EPR Core Insulation — Cross-linked zero-halogen numbered core insulation

Resistance

Oil, grease, ozone & UV resistance
Resistant to wind turbine gearbox oil, hydraulic fluid, ozone and UV weathering per IEC 60332-3-22/24, IEC 60754-2 & UL 1,000 V FRNC/LSZH (±150°/m) Wind Specification
Flame retardancy & smoke/halogen emission
Flame-retardant and environmental performance verified per IEC 60332-3-22/24, IEC 60754-2 & UL 1,000 V FRNC/LSZH (±150°/m) Wind Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
IEC 60332-3-22/24, IEC 60754-2 & UL 1,000 V FRNC/LSZH (±150°/m) Wind Specification
Conductor & flame/test standards
IEC 60228 / IEC 60332-1-2 & -3 / UL 2277 WTTC / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
FRNC 0.6/1 kV Drip-Loop
Sheath colour & metre marking
Continuous metre-marked black outer finish (FRNC/LSZH Thermo)
Customs tariff (HS)
8544.49 / 8544.60

Sizes

3 standard FRNC 0.6/1 kV Drip-Loop wind turbine configurations

Manufactured to IEC 60332-3-22/24, IEC 60754-2 & UL 1,000 V FRNC/LSZH (±150°/m) Wind Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
FRNC 0.6/1 kV Drip-Loop Construction Schedule (−40…+90 °C)
FRNC 0.6 7G1.5 mm²7G1.5 mm² (or 7C × 16 AWG)IEC 60228 Class 5/6 / Class K Cu11.42152.470
FRNC 0.6 12G1.5 mm²12G1.5 mm² (or 12C × 16 AWG)IEC 60228 Class 5/6 / Class K Cu14.83454.190
FRNC 0.6 18G2.5 mm²18G2.5 mm² (or 18C × 14 AWG)IEC 60228 Class 5/6 / Class K Cu19.66809.8120
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom conductor cross-sections, core counts, pre-lugged tower kits and drum lengths available per IEC 60332-3-22/24, IEC 60754-2 & UL 1,000 V FRNC/LSZH (±150°/m) Wind Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (IEC 60332-3-22/24, IEC 60754-2 & UL 1,000 V FRNC/LSZH (±150°/m) Wind Specification)DC resistance at 20 °C and insulation/sheath wall thickness within IEC 60332-3-22/24, IEC 60754-2 & UL 1,000 V FRNC/LSZH (±150°/m) Wind Specification limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (IEC 60332-3-22/24, IEC 60754-2 & UL 1,000 V FRNC/LSZH (±150°/m) Wind Specification)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV / 1,000 V ratingEvery manufactured drum length
Sample tests
Low-temperature drip-loop torsion, oil & flame qualification (IEC 60332-3-22/24, IEC 60754-2 & UL 1,000 V FRNC/LSZH (±150°/m) Wind Specification)Verified cold torsion cycle endurance, oil resistance and flame retardancy across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60332-3 / UL 1000V CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX FRNC 0.6/1 kV Drip-Loop IEC 60332-3 / UL 1000V 0.6/1 kV / 1,000 V CE
Delivery form
Heavy-duty export fumigated wooden drums, steel reels or pre-cut wind turbine tower & drip-loop kits
Standard lengths
500 m, 1,000 m or custom cut-to-length nacelle drip-loop and tower section sets
MOQ
100 m (standard configurations) · 300 m (custom wind builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-27
Updated
2026-10-27

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define FRNC 0.6/1 kV Drip-Loop (FRNC / LSZH 0.6/1 kV (IEC) & 1,000 V (UL) Halogen-Free Flame-Retardant Wind Drip-Loop Torsion Cable)?
FRNC 0.6/1 kV Drip-Loop (FRNC / LSZH 0.6/1 kV (IEC) & 1,000 V (UL) Halogen-Free Flame-Retardant Wind Drip-Loop Torsion Cable) is manufactured in accordance with IEC 60332-3-22/24, IEC 60754-2 & UL 1,000 V FRNC/LSZH (±150°/m) Wind Specification for 0.6/1 kV / 1,000 V wind turbine service over -40 to +90 °C. Its 3-layer construction comprises class 5 flexible bare copper (2-37 cores, 0.5-95 mm²), halogen-free xlpo / epr core insulation and frnc/lszh thermoset outer sheath (±150°/m).
What is the minimum bending radius and operating temperature range for FRNC 0.6/1 kV Drip-Loop?
The minimum bending radius for FRNC 0.6/1 kV Drip-Loop is 6 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical torsion resistance and dielectric reliability in wind turbine nacelles, hubs and towers.
How are the concentric layers of FRNC 0.6/1 kV Drip-Loop arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Class 5 Flexible Bare Copper (2-37 Cores, 0.5-95 mm²) — Stranded plain copper conductors for control & auxiliary power; (02) Halogen-Free XLPO / EPR Core Insulation — Cross-linked zero-halogen numbered core insulation; (03) FRNC/LSZH Thermoset Outer Sheath (±150°/m) — Flame-retardant non-corrosive low-smoke elastomer jacket.
What factory test certificates are supplied with FRNC 0.6/1 kV Drip-Loop?
Every production drum of FRNC 0.6/1 kV Drip-Loop undergoes routine conductor DC resistance, AC high-voltage dielectric and dimensional testing per IEC 60332-3-22/24, IEC 60754-2 & UL 1,000 V FRNC/LSZH (±150°/m) Wind Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for FRNC 0.6/1 kV Drip-Loop

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

FRNC / LSZH 0.6/1 kV (IEC) & 1,000 V (UL) Halogen-Free Flame-Retardant Wind Drip-Loop Torsion Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote