Fixed installation
Mica glass-fibre fire barrier or ceramifying silicone insulation maintains circuit integrity during 750–1,100 °C fire exposure.
Product
MPRX 331 & MPRXCX 331 0.6/1 (1.2) kV (Flexible Marine) Mica-Tape/Barrier + XLPE Insulated Copper-Braided SHF1 Fire-Resistant Shipboard Cable (IEC 60331-21 / IEC 60092-353, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on IEC 60331-1/21 & IEC 60092-353 / IEC 60092-360 SHF1 — confirmed in the datasheet and quotation for your order.
Application fit
MPRX 331 & MPRXCX 331 0.6/1 (1.2) kV (Flexible Marine) Mica-Tape/Barrier + XLPE Insulated Copper-Braided SHF1 Fire-Resistant Shipboard Cable (IEC 60331-21 / IEC 60092-353, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).
Mica glass-fibre fire barrier or ceramifying silicone insulation maintains circuit integrity during 750–1,100 °C fire exposure.
Low-smoke zero-halogen SHF1/SHF2/SW4 sheath minimizes toxic gas and smoke opacity during marine evacuation.
Metallic wire braid armour resists mechanical shock, water spray (+WSR) and water jet (+WJR) firefighting impact.
Terminates directly into emergency switchboards, fire-alarm panels, PA/GA systems and watertight glands.
Mica-taped fire-resistant shipboard cable is designed for fixed installation, not continuous reeling drums.
Use HVSC Shore Power Reeling CableConstruction
Shown: MPRX 331 & MPRXCX 331 0.6/1 KV (IEC 60331-1/21 & IEC 60092-353 / IEC 60092-360 SHF1) featuring flexible copper conductors (4×16 mm²), mica / barrier fire barrier (iec 60331) and shf1 fire-safe outer sheath (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Flexible Copper Conductors (4×16 mm²) | IEC 60228 Class 2 / Class 5 annealed copper conductors |
| 2 | Mica / Barrier Fire Barrier (IEC 60331) | Fire-resistant mica glass tape maintaining insulation under fire |
| 3 | XLPE Core Insulation | 90 °C cross-linked polyethylene coded Brown, Black, Grey, Blue |
| 4 | Copper Wire Braid Armour (MPRXCX 331) | Annealed bare copper wire braid armour over halogen-free bedding |
| 5 | SHF1 Fire-Safe Outer Sheath | Low-smoke zero-halogen polyolefin jacket certified to SOLAS & IEC 60331 |
Built to IEC 60331-1/21 & IEC 60092-353 / IEC 60092-360 SHF1 with flexible copper conductors (4×16 mm²) and shf1 fire-safe outer sheath
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to IEC 60331-1/21 & IEC 60092-353 / IEC 60092-360 SHF1 for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| MPRX 331 & MPRXCX 331 0.6/1 KV Construction Schedule (−40…+90 °C) | |||||||
| MPRX 331 3×16+1G16 mm² | 3 × 16 + 1G16 mm² (4G16) | IEC 60228 Class 2/5 Cu/SnCu | 22.4 | 920 | 3.8 | 135 | |
| MPRX 331 3×35+1G16 mm² | 3 × 35 + 1G16 mm² (4G35) | IEC 60228 Class 2/5 Cu/SnCu | 28.8 | 1,690 | 7.4 | 175 | |
| MPRX 331 3×70+1G35 mm² | 3 × 70 + 1G35 mm² (4G70) | IEC 60228 Class 2/5 Cu/SnCu | 38.2 | 3,260 | 14.8 | 230 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 16 + 1G16 mm² (4G16) | 1.15 | 0.6/1 kV (98 A) | −40…+90 °C |
| 3 × 35 + 1G16 mm² (4G35) | 0.52 | 0.6/1 kV (158 A) | −40…+90 °C |
| 3 × 70 + 1G35 mm² (4G70) | 0.27 | 0.6/1 kV (245 A) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEC 60331-1/21 & IEC 60092-353 / IEC 60092-360 SHF1) | DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60331-1/21 & IEC 60092-353 / IEC 60092-360 SHF1 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEC 60331-1/21 & IEC 60092-353 / IEC 60092-360 SHF1) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (IEC 60331-1/21 & IEC 60092-353 / IEC 60092-360 SHF1) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.