Contact
fire-resistant shipboard & offshore cableIEC 60331 / IEC 60092-3530.6/1 kV (-40 to +90 °C)SHF1 Halogen-Free Outer Sheath

MHXCH FE120 & FMHXCH FE120 0.6/1 kV / 250 V S95 Ceramifying Silicone Fire-Resistant Shipboard CableIEC 60331 / IEC 60092-353 — 0.6/1 kV — -40 to +90 °C Marine & Offshore Cable

MHXCH FE120 & MHXH FE120 0.6/1 kV & FMHXCH FE120 250 V S95 Ceramized-Elastomer Insulated Copper-Braided SHF1 Fire-Resistant Shipboard Cable (IEC 60331 / IEC 60092-353, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).

Flame-retardant
EMC screen
Oil-resistant
Approved
Order designation
MHXCH FE120 4G2.5 mm²
Outer Ø ≈
13.2 mm
Net weight ≈
275 kg/km
Tensile rating ≈
1.5 kN
Core / stranding
IEC 60228 Class 2/5 Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per IEC 60331 / IEC 60092-353
Operating temp.
−40…+90 °C
Continuous shipboard & offshore service
Min. bend radius
6 × OD
Marine tray, bulkhead & deck routing
Core / conductor
Tinned Copper Co
Stranded tinned annealed copper conducto
Outer protection
SHF1 Halogen-Fre
Low-smoke zero-halogen polyolefin jacket
Standard
IEC 60331 / IEC
IEC 60331 (FE120) / IEC 60092-353 & 6009

Typical values for this cable type, based on IEC 60331 (FE120) / IEC 60092-353 & 60092-376 S95 Ceramifying Elastomer — confirmed in the datasheet and quotation for your order.

Application fit

Is MHXCH FE120 & FMHXCH FE120 right for your machine?

MHXCH FE120 & MHXH FE120 0.6/1 kV & FMHXCH FE120 250 V S95 Ceramized-Elastomer Insulated Copper-Braided SHF1 Fire-Resistant Shipboard Cable (IEC 60331 / IEC 60092-353, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).

Fixed installation

Suitable

Mica glass-fibre fire barrier or ceramifying silicone insulation maintains circuit integrity during 750–1,100 °C fire exposure.

Offshore platform & shipboard deck trays

Suitable

Low-smoke zero-halogen SHF1/SHF2/SW4 sheath minimizes toxic gas and smoke opacity during marine evacuation.

Drilling jumbo & rotary mast feed

Suitable

Metallic wire braid armour resists mechanical shock, water spray (+WSR) and water jet (+WJR) firefighting impact.

Switchgear & control cabinet wiring

Suitable

Terminates directly into emergency switchboards, fire-alarm panels, PA/GA systems and watertight glands.

Motorised monospiral reel

Not suitable

Mica-taped fire-resistant shipboard cable is designed for fixed installation, not continuous reeling drums.

Use HVSC Shore Power Reeling Cable
Typical machinesBuilding & Fire SafetyOffshore Emergency Shutdown (ESD) & DelugePassenger Cruise & Ferry Safe-Return-to-PortShipboard Fire Alarm, PA/GA & Emergency LightingFPSO & Petrochemical Hydrocarbon Fire Zones

Construction

Layer by layer

Shown: MHXCH FE120 & FMHXCH FE120 (IEC 60331 (FE120) / IEC 60092-353 & 60092-376 S95 Ceramifying Elastomer) featuring tinned copper conductors (7×1.5 mm²), s95 ceramifying silicone insulation (hx) and shf1 halogen-free outer sheath (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Tinned Copper Conductors (7×1.5 mm²)Stranded tinned annealed copper conductors
2S95 Ceramifying Silicone Insulation (HX)Cross-linked silicone elastomer forming protective ceramic shell in fire (FE120)
3Halogen-Free Inner CoveringFlame-retardant halogen-free bedding compound and glass tape
4Copper Wire Braid Screen (C)High-coverage copper wire braid for EMC and mechanical protection
5SHF1 Halogen-Free Outer SheathLow-smoke zero-halogen polyolefin jacket

MHXCH FE120 & FMHXCH FE120 — Standard Shipboard & Offshore Execution

Built to IEC 60331 (FE120) / IEC 60092-353 & 60092-376 S95 Ceramifying Elastomer with tinned copper conductors (7×1.5 mm²) and shf1 halogen-free outer sheath

MHXCH FE120 & FMHXCH FE120 — Custom Drum Length & Gland Kit

Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands

MHXCH FE120 & FMHXCH FE120 — Class & Routine Test Certified

Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60331 (FE120) / IEC 60092-353 & 60092-376 S95 Ceramifying Elastomer. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (IEC 60331 (FE120) / IEC 60092-353 & 60092-376 S95 Ceramifying Elastomer)
Core / conductor construction
Tinned Copper Conductors (7×1.5 mm²) — Stranded tinned annealed copper conductors
Primary dielectric / buffering
S95 Ceramifying Silicone Insulation (HX) — Cross-linked silicone elastomer forming protective ceramic shell in fire (FE120)

Thermal

Continuous operating temperature
−40…+90 °C (shipboard & offshore duty)
Short-circuit / peak thermal rating
Verified thermal stability per IEC 60331 (FE120) / IEC 60092-353 & 60092-376 S95 Ceramifying Elastomer
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
SHF1 Halogen-Free Outer Sheath — Low-smoke zero-halogen polyolefin jacket
Minimum bending radius
6 × OD
Armour, screen & mechanical duty
Copper Wire Braid Screen (C) — High-coverage copper wire braid for EMC and mechanical protection

Resistance

Flame, fire & smoke performance
Qualified for marine flame-retardance and low-smoke zero-halogen / fire safety per IEC 60331 (FE120) / IEC 60092-353 & 60092-376 S95 Ceramifying Elastomer
Oil, drilling mud & seawater resistance
Resistant to marine fuel/lube oils, salt mist and offshore fluids per IEC 60331 (FE120) / IEC 60092-353 & 60092-376 S95 Ceramifying Elastomer
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
IEC 60331 (FE120) / IEC 60092-353 & 60092-376 S95 Ceramifying Elastomer
Environmental & test standards
IEC 60228 / IEC 60332-3-22 / IEC 60754 / IEC 61034 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
MHXCH FE120 & FMHXCH FE120
Sheath colour & metre marking
Continuous metre-marked black outer finish (SHF1 Halogen-Fre)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard MHXCH FE120 & FMHXCH FE120 shipboard & offshore configurations

Manufactured to IEC 60331 (FE120) / IEC 60092-353 & 60092-376 S95 Ceramifying Elastomer for shipboard, offshore platform, drilling rig and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
MHXCH FE120 & FMHXCH FE120 Construction Schedule (−40…+90 °C)
MHXCH FE120 4G2.5 mm²4 × 2.5 mm² (or 4C × 14 AWG)IEC 60228 Class 2/5 Cu/SnCu13.22751.580
MHXCH FE120 7G2.5 mm²7 × 2.5 mm² (or 7C × 14 AWG)IEC 60228 Class 2/5 Cu/SnCu15.84152.695
MHXCH FE120 12G1.5 mm²12 × 1.5 mm² (or 12C × 16 AWG)IEC 60228 Class 2/5 Cu/SnCu17.44952.7105
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per IEC 60331 (FE120) / IEC 60092-353 & 60092-376 S95 Ceramifying Elastomer.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (IEC 60331 (FE120) / IEC 60092-353 & 60092-376 S95 Ceramifying Elastomer)DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60331 (FE120) / IEC 60092-353 & 60092-376 S95 Ceramifying Elastomer tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (IEC 60331 (FE120) / IEC 60092-353 & 60092-376 S95 Ceramifying Elastomer)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Flame, fire integrity, oil/mud & mechanical qualification (IEC 60331 (FE120) / IEC 60092-353 & 60092-376 S95 Ceramifying Elastomer)Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60331 / IEC 60092-353 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX MHXCH FE120 & FMHXCH FE120 IEC 60331 / IEC 60092-353 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel marine reels
Standard lengths
500 m, 1,000 m or custom continuous shipboard/offshore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define MHXCH FE120 & FMHXCH FE120 (MHXCH FE120 & FMHXCH FE120 0.6/1 kV / 250 V S95 Ceramifying Silicone Fire-Resistant Shipboard Cable)?
MHXCH FE120 & FMHXCH FE120 (MHXCH FE120 & FMHXCH FE120 0.6/1 kV / 250 V S95 Ceramifying Silicone Fire-Resistant Shipboard Cable) is manufactured in accordance with IEC 60331 (FE120) / IEC 60092-353 & 60092-376 S95 Ceramifying Elastomer for 0.6/1 kV service over -40 to +90 °C. Its 5-layer construction comprises tinned copper conductors (7×1.5 mm²), s95 ceramifying silicone insulation (hx) and shf1 halogen-free outer sheath.
What is the minimum bending radius and operating temperature range for MHXCH FE120 & FMHXCH FE120?
The minimum bending radius for MHXCH FE120 & FMHXCH FE120 is 6 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical and dielectric reliability in shipboard and offshore service.
How are the concentric layers of MHXCH FE120 & FMHXCH FE120 arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Tinned Copper Conductors (7×1.5 mm²) — Stranded tinned annealed copper conductors; (02) S95 Ceramifying Silicone Insulation (HX) — Cross-linked silicone elastomer forming protective ceramic shell in fire (FE120); (03) Halogen-Free Inner Covering — Flame-retardant halogen-free bedding compound and glass tape; (04) Copper Wire Braid Screen (C) — High-coverage copper wire braid for EMC and mechanical protection; (05) SHF1 Halogen-Free Outer Sheath — Low-smoke zero-halogen polyolefin jacket.
What factory test certificates are supplied with MHXCH FE120 & FMHXCH FE120?
Every production drum of MHXCH FE120 & FMHXCH FE120 undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per IEC 60331 (FE120) / IEC 60092-353 & 60092-376 S95 Ceramifying Elastomer, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for MHXCH FE120 & FMHXCH FE120

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

MHXCH FE120 & FMHXCH FE120 0.6/1 kV / 250 V S95 Ceramifying Silicone Fire-Resistant Shipboard Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote