Contact

ZW-NOTKtsdD All-Dielectric LSOH Mine Shaft Optical CableZW-NOTKtsdD EMAG-certified all-dielectric optical telecom cable for underground coal mines, vertical shafts and tunnels, combining a central FRP rod (D), SZ gel-filled PBT loose tubes (ts), dry core yarns (d), 4500 N aramid and black LSOH jacket.

Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per ZN-TF-116 / EN 60794-1-2 / IEC 60332-3-22 across -40 to +70 °C.

Flame-retardant
Water-resistant
Approved
Outdoor & humid
Order designation
ZW-NOTKtsdD 72J (6×12F) G.652.D LSOH
Outer Ø ≈
12.2 mm
Net weight ≈
142 kg/km
Tensile rating ≈
3.5 kN
Core / stranding
SZ gel tubes + Dry Core + Aramid
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
Optical
All-dielectric mine shaft optical trunk
Operating temp.
-40 to +70 °C
Continuous mining & industrial duty
Min. bend radius
15 × OD
Fixed installation / dynamic routing
Core / conductor
12–144F SM/MM
SZ gel-filled PBT tubes + dry core (tsd)
Outer protection
Aramid + LSOH
4500 N aramid + Cat. A halogen-free LSOH
Standard
ZN-TF-116 / LSOH
ZN-TF-116 / EN 60794-1-2 / 60332-3-22

Typical values for this cable type, based on ZN-TF-116 / EN 60794-1-2 / IEC 60332-3-22 — confirmed in the datasheet and quotation for your order.

Application fit

Is ZW-NOTKtsdD right for your machine?

Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per ZN-TF-116 / EN 60794-1-2 / IEC 60332-3-22 across -40 to +70 °C.

Mine roadway & tunnel wall hangers

Suitable

Engineered for underground mining shafts, galleries and tunnel infrastructure per ZN-TF-116 / EN 60794-1-2 / IEC 60332-3-22.

Fixed installation

Suitable

Suitable for vertical shaft cleats, gallery messenger hooks and tray routing within 15 × OD.

Free-hanging vertical run

Suitable

Supports inclined roadway and vertical mine shaft suspension within rated kN load across -40 to +70 °C.

Typical machinesMining & TunnellingUnderground Coal & Hard-Rock MiningOpen-Cast Excavators, Draglines & ShovelsVertical Mine Shafts, Hoists & BoreholesTunneling, Mineral Processing & Slurry Plants

Construction

Layer by layer

Shown: ZW-NOTKtsdD (ZN-TF-116 / EN 60794-1-2 / IEC 60332-3-22) featuring central dielectric rod (d), gel-filled loose tubes (6×12f ts) and black lsoh / frnc outer sheath (zw-n) (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Central Dielectric Rod (D)Non-metallic Fiber-Reinforced Plastic (FRP) central strength member
2Gel-Filled Loose Tubes (6×12F ts)SZ-stranded PBT tubes containing up to 12 optical fibres per tube
3Dry Core Water-Blocking System (d)Water-swellable yarns and tape for drip-free vertical shaft installation
4Peripheral Aramid ReinforcementHigh-modulus aramid yarns providing 3000–4500 N metal-free tensile rating
5Black LSOH / FRNC Outer Sheath (ZW-N)UV-stabilized black halogen-free, low-smoke flame-retardant outer jacket

ZW-NOTKtsdD — Standard Mining Execution

Built to ZN-TF-116 / EN 60794-1-2 / IEC 60332-3-22 with central dielectric rod (d) and black lsoh / frnc outer sheath (zw-n)

ZW-NOTKtsdD — Custom Drum Length & Gland Kit

Available in custom shaft/roadway drum lengths or pre-terminated assemblies

ZW-NOTKtsdD — Routine & Flame Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on ZN-TF-116 / EN 60794-1-2 / IEC 60332-3-22. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
Optical (ZN-TF-116 / EN 60794-1-2 / IEC 60332-3-22)
Core / conductor construction
Central Dielectric Rod (D) — Non-metallic Fiber-Reinforced Plastic (FRP) central strength member
Primary dielectric / buffering
Gel-Filled Loose Tubes (6×12F ts) — SZ-stranded PBT tubes containing up to 12 optical fibres per tube

Thermal

Continuous operating temperature
-40 to +70 °C (mining & industrial service)
Short-circuit / peak thermal rating
Verified thermal stability per ZN-TF-116 / EN 60794-1-2 / IEC 60332-3-22
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Black LSOH / FRNC Outer Sheath (ZW-N) — UV-stabilized black halogen-free, low-smoke flame-retardant outer jacket
Minimum bending radius
15 × OD
Crush, impact & abrasion duty
Heavy-duty mining rock-cut, impact and tensile protection per ZN-TF-116 / EN 60794-1-2 / IEC 60332-3-22

Resistance

Flame retardancy & mine fire safety
Self-extinguishing / flame-retardant mining jacket per ZN-TF-116 / EN 60794-1-2 / IEC 60332-3-22
Mine water, oil & chemical resistance
Resistant to acidic mine water, hydraulic oils and abrasion per ZN-TF-116 / EN 60794-1-2 / IEC 60332-3-22
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
ZN-TF-116 / EN 60794-1-2 / IEC 60332-3-22
Flame & environmental test standards
IEC 60332 / MSHA / EN 60794 / IEC 60228
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
ZW-NOTKtsdD
Sheath colour & metre marking
Continuous metre-marked black mining outer sheath
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard ZW-NOTKtsdD mining & industrial configurations

Manufactured to ZN-TF-116 / EN 60794-1-2 / IEC 60332-3-22 for underground mining, open-cast excavation, shaft and heavy industrial systems.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
ZW-NOTKtsdD Construction Schedule (-40 to +70 °C)
ZW-NOTKtsdD 24J (6×4F) G.652.D LSOH24 × SM G.652.D (6×4F All-Dielectric)SZ gel tubes + Dry Core + Aramid11.41223.0170
ZW-NOTKtsdD 72J (6×12F) G.652.D LSOH72 × SM G.652.D (6×12F All-Dielectric)SZ gel tubes + Dry Core + Aramid12.21423.5185
ZW-NOTKtsdD 144J (12×12F) G.652.D LSOH144 × SM G.652.D (12×12F All-Dielectric)SZ gel tubes + Dry Core + Aramid15.82254.5240
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per ZN-TF-116 / EN 60794-1-2 / IEC 60332-3-22.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (ZN-TF-116 / EN 60794-1-2 / IEC 60332-3-22)DC resistance at 20 °C / optical attenuation and outer diameter within ZN-TF-116 / EN 60794-1-2 / IEC 60332-3-22 tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (ZN-TF-116 / EN 60794-1-2 / IEC 60332-3-22)Zero dielectric breakdown and verified insulation resistance over full production lengthEvery manufactured drum length
Sample tests
Flame propagation, mechanical crush & thermal ageing qualification (ZN-TF-116 / EN 60794-1-2 / IEC 60332-3-22)Verified flame retardancy, mechanical integrity and thermal endurance across -40 to +70 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

ZN-TF-116 / LSOH CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX ZW-NOTKtsdD ZN-TF-116 / LSOH Optical CE
Delivery form
Heavy-duty export fumigated wooden drums or steel mine reels
Standard lengths
500 m, 1,000 m or custom continuous shaft/reeling lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-24
Updated
2026-10-24

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define ZW-NOTKtsdD (ZW-NOTKtsdD All-Dielectric LSOH Mine Shaft Optical Cable)?
ZW-NOTKtsdD (ZW-NOTKtsdD All-Dielectric LSOH Mine Shaft Optical Cable) is manufactured in accordance with ZN-TF-116 / EN 60794-1-2 / IEC 60332-3-22 for Optical duty over -40 to +70 °C. Its 5-layer construction comprises Central Dielectric Rod (D), Gel-Filled Loose Tubes (6×12F ts) and Black LSOH / FRNC Outer Sheath (ZW-N).
What is the minimum bending radius and operating temperature range for ZW-NOTKtsdD?
The minimum bending radius for ZW-NOTKtsdD is 15 × OD across its continuous operating temperature range of -40 to +70 °C, ensuring mechanical and dielectric reliability in mining and heavy industrial service.
How are the concentric layers of ZW-NOTKtsdD arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Central Dielectric Rod (D) (Non-metallic Fiber-Reinforced Plastic (FRP) central strength member); (02) Gel-Filled Loose Tubes (6×12F ts) (SZ-stranded PBT tubes containing up to 12 optical fibres per tube); (03) Dry Core Water-Blocking System (d) (Water-swellable yarns and tape for drip-free vertical shaft installation); (04) Peripheral Aramid Reinforcement (High-modulus aramid yarns providing 3000–4500 N metal-free tensile rating); (05) Black LSOH / FRNC Outer Sheath (ZW-N) (UV-stabilized black halogen-free, low-smoke flame-retardant outer jacket).
What factory test certificates are supplied with ZW-NOTKtsdD?
Every production drum of ZW-NOTKtsdD undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per ZN-TF-116 / EN 60794-1-2 / IEC 60332-3-22, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for ZW-NOTKtsdD

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

ZW-NOTKtsdD All-Dielectric LSOH Mine Shaft Optical Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote