Contact

NF M 87-202 EIPF CR1-C1 Fire-Resistant Lead-Sheathed Armoured CableNF M 87-202 / NF C 32-070 CR1-C1 · 500 V · -30 °C to +90 °C industrial EIPF CR1-C1

NF M 87-202 EIPF CR1-C1 Fire-Resistant Lead-Sheathed Armoured Instrument Cable (EIPF CR1-C1) engineered to NF M 87-202 / NF C 32-070 CR1-C1 for 500 V service across -30 °C to +90 °C, featuring stranded stranded copper conductor and lszh outer sheath with

Approved
Low-EMC design
EMC screen
Oil-resistant
Order designation
EIPF CR1-C1 4×2×1.0
Outer Ø ≈
13.5 mm
Total weight ≈
264 kg/km
Min. bend R (fixed)
108 mm
Configuration
4×2×1.0 mm²
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
500 V
Per NF M 87-202 / NF C 32-070 CR1-C1
Operating temp.
−30…+90 °C
Continuous thermal rating
Min. bend radius
12 × OD
Installed / fixed routing
Conductor
stranded copper
High-conductivity stranded copper
Outer layer
LSZH outer
Extruded LSZH outer sheath protective
Standard
NF M 87-202
NF M 87-202 / NF C 32-070 CR1-C1

Typical values for this cable type, based on NF M 87-202 / NF C 32-070 CR1-C1 — confirmed in the datasheet and quotation for your order.

Application fit

Is EIPF CR1-C1 right for your machine?

NF M 87-202 EIPF CR1-C1 Fire-Resistant Lead-Sheathed Armoured Instrument Cable (EIPF CR1-C1) engineered to NF M 87-202 / NF C 32-070 CR1-C1 for 500 V service across -30 °C to +90 °C, featuring stranded stranded copper conductor and lszh outer sheath with

Fixed installation

Suitable

Engineered and verified for fixed service in accordance with NF M 87-202 / NF C 32-070 CR1-C1.

Switchgear & control cabinet wiring

Suitable

Suitable for switchgear, control panels and equipment terminations within 12 × OD bend radius.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Motorised monospiral reel

Not suitable

Not designed for high-speed monospiral crane reeling; select a dedicated reeling cable.

NSHTOU Reeling Cable
Typical machinesOil & Gas CableRefinery & Petrochemical Process UnitsLNG Terminals & Tank FarmsOnshore & Offshore Oil & Gas FacilitiesChemical & Hydrocarbon Processing PlantsCommercial & Residential Building Distribution

Construction

Layer by layer

Shown: EIPF CR1-C1 (NF M 87-202 / NF C 32-070 CR1-C1) with stranded stranded copper conductor, al/pet individual screen and lszh outer sheath (11-layer construction).

1234567891011
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded stranded copper conductorHigh-conductivity stranded copper conductor per NF M 87-202 / NF C 32-070 CR1-C1NF M 87-202 / NF C 32-070 CR1-C1
2Al/PET individual screenAl/PET individual screen metallic electromagnetic screen (individual core / group layer)NF M 87-202 / NF C 32-070 CR1-C1
3LSZH individual sheathExtruded LSZH individual sheath protective layer (individual core / group layer)NF M 87-202 / NF C 32-070 CR1-C1
4Silicone rubber core insulationExtruded Silicone rubber dielectric (individual core / group layer)NF M 87-202 / NF C 32-070 CR1-C1
5Plastic binder tapeHelically applied plastic binder tapeNF M 87-202 / NF C 32-070 CR1-C1
6Al/PET overall screenAl/PET overall screen metallic electromagnetic screen (lapped tape)NF M 87-202 / NF C 32-070 CR1-C1
7LSZH inner sheathExtruded LSZH inner sheath protective layer (continuous layer)NF M 87-202 / NF C 32-070 CR1-C1
8Lead moisture barrierExtruded Lead moisture barrier protective layer (continuous layer)NF M 87-202 / NF C 32-070 CR1-C1
9Inner steel armour tapeInner steel armour tape mechanical protection (lapped tape)NF M 87-202 / NF C 32-070 CR1-C1
10Outer steel armour tapeOuter steel armour tape mechanical protection (lapped tape)NF M 87-202 / NF C 32-070 CR1-C1
11LSZH outer sheathExtruded LSZH outer sheath protective layer (continuous layer)NF M 87-202 / NF C 32-070 CR1-C1

EIPF CR1-C1 — Standard Execution

Built to NF M 87-202 / NF C 32-070 CR1-C1 with stranded stranded copper conductor and lszh outer sheath

EIPF CR1-C1 — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per NF M 87-202 / NF C 32-070 CR1-C1

EIPF CR1-C1 — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on NF M 87-202 / NF C 32-070 CR1-C1. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
500 V (NF M 87-202 / NF C 32-070 CR1-C1)
Conductor construction
Stranded stranded copper conductor — High-conductivity stranded copper conductor per NF M 87-202 / NF C 32-070 CR1-C1
Primary insulation / dielectric
Al/PET individual screen — Al/PET individual screen metallic electromagnetic screen (individual core / group layer)

Thermal

Continuous operating temperature
−30…+90 °C per NF M 87-202 / NF C 32-070 CR1-C1
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
LSZH outer sheath — Extruded LSZH outer sheath protective layer (continuous layer)
Minimum bending radius
12 × OD (installed / static routing)
Layer count & geometry
11 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with NF M 87-202 / NF C 32-070 CR1-C1
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
NF M 87-202 / NF C 32-070 CR1-C1
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
EIPF CR1-C1
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

12 standard EIPF CR1-C1 cable configurations

Manufactured to NF M 87-202 / NF C 32-070 CR1-C1 in single-pair, multi-pair and multi-unit constructions.

Dimensions, construction & weights
Order designationConfigurationOuter Ø ≈
mm
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
EIPF CR1-C1 Standard Construction Schedule (500 V · −30…+90 °C)
EIPF CR1-C1 1×2×0.51×2×0.5 mm²6.45852
EIPF CR1-C1 2×2×0.52×2×0.5 mm²9.211274
EIPF CR1-C1 4×2×0.54×2×0.5 mm²11.417692
EIPF CR1-C1 8×2×0.58×2×0.5 mm²14.8295118
EIPF CR1-C1 12×2×0.512×2×0.5 mm²17.6420141
EIPF CR1-C1 1×2×1.01×2×1.0 mm²7.68661
EIPF CR1-C1 2×2×1.02×2×1.0 mm²11.016888
EIPF CR1-C1 4×2×1.04×2×1.0 mm²13.5264108
EIPF CR1-C1 8×2×1.08×2×1.0 mm²17.9465143
EIPF CR1-C1 1×2×1.51×2×1.5 mm²8.511468
EIPF CR1-C1 4×2×1.54×2×1.5 mm²15.2348122
EIPF CR1-C1 12×2×1.512×2×1.5 mm²23.4860187
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Additional pair/triad/quad counts (up to 48 pairs) and blue Ex-i intrinsically safe outer sheaths available per NF M 87-202 / NF C 32-070 CR1-C1.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (NF M 87-202 / NF C 32-070 CR1-C1)DC resistance at 20 °C and geometry within NF M 87-202 / NF C 32-070 CR1-C1 class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (NF M 87-202 / NF C 32-070 CR1-C1)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (NF M 87-202 / NF C 32-070 CR1-C1)Full compliance with NF M 87-202 / NF C 32-070 CR1-C1 across −30…+90 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

NF M 87-202 CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX EIPF CR1-C1 <size> NF M 87-202 500 V CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define EIPF CR1-C1 (NF M 87-202 EIPF CR1-C1 Fire-Resistant Lead-Sheathed Armoured Instrument Cable)?
EIPF CR1-C1 (NF M 87-202 EIPF CR1-C1 Fire-Resistant Lead-Sheathed Armoured Instrument Cable) is manufactured in accordance with NF M 87-202 / NF C 32-070 CR1-C1 for 500 V service over -30 °C to +90 °C. Its 11-layer construction comprises stranded stranded copper conductor, al/pet individual screen, lszh individual sheath, silicone rubber core insulation, plastic binder tape, al/pet overall screen, lszh inner sheath, lead moisture barrier, inner steel armour tape, outer steel armour tape, lszh outer sheath.
What is the minimum bending radius and installation temperature for EIPF CR1-C1?
The minimum installed bending radius for EIPF CR1-C1 is 12 × OD across its continuous operating temperature range of -30 °C to +90 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of EIPF CR1-C1 arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded stranded copper conductor (High-conductivity stranded copper conductor per NF M 87-202 / NF C 32-070 CR1-C1); (02) Al/PET individual screen (Al/PET individual screen metallic electromagnetic screen (individual core / group layer)); (03) LSZH individual sheath (Extruded LSZH individual sheath protective layer (individual core / group layer)); (04) Silicone rubber core insulation (Extruded Silicone rubber dielectric (individual core / group layer)); (05) Plastic binder tape (Helically applied plastic binder tape); (06) Al/PET overall screen (Al/PET overall screen metallic electromagnetic screen (lapped tape)); (07) LSZH inner sheath (Extruded LSZH inner sheath protective layer (continuous layer)); (08) Lead moisture barrier (Extruded Lead moisture barrier protective layer (continuous layer)); (09) Inner steel armour tape (Inner steel armour tape mechanical protection (lapped tape)); (10) Outer steel armour tape (Outer steel armour tape mechanical protection (lapped tape)); (11) LSZH outer sheath (Extruded LSZH outer sheath protective layer (continuous layer)).
What factory test certificates are supplied with EIPF CR1-C1?
Every production drum or spool of EIPF CR1-C1 undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per NF M 87-202 / NF C 32-070 CR1-C1, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for EIPF CR1-C1

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

NF M 87-202 EIPF CR1-C1 Fire-Resistant Lead-Sheathed Armoured Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote