144-Fiber Multi-Subunit Tight-Buffered Riser Distribution FiberICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR · All-Dielectric Optical · -20 °C to +70 °C

144-core optical Multi-Subunit Tight-Buffered Riser Distribution Fiber Optic Cable (OFNR-144F Tight-Buffered Distribution) engineered to ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR for All-Dielectric Optical service across -20 °C to +70 °C, featuring dielectric

Approved
Flame-retardant
Oil-resistant
Order designation
OFNR-144F Tight-Buffered Distribution 4×2×1.0
Outer Ø ≈
13.5 mm
Total weight ≈
264 kg/km
Min. bend R (fixed)
108 mm
Configuration
4×2×1.0 mm²
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
All-Dielectric
Per ICEA S-83-596 / ANSI/TIA-568 / UL
Operating temp.
−20…+70 °C
Continuous thermal rating
Min. bend radius
10 × OD
Installed / fixed routing
Conductor
Dielectric
Dielectric strength rod assembly per
Outer layer
Flame-retardant
Extruded Flame-retardant outer jacket
Standard
ICEA S-83-596
ICEA S-83-596 / ANSI/TIA-568 / UL

Typical values for this cable type, based on ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR — confirmed in the datasheet and quotation for your order.

Application fit

Is OFNR-144F Tight-Buffered Distribution right for your machine?

144-core optical Multi-Subunit Tight-Buffered Riser Distribution Fiber Optic Cable (OFNR-144F Tight-Buffered Distribution) engineered to ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR for All-Dielectric Optical service across -20 °C to +70 °C, featuring dielectric

Fixed installation

Suitable

Engineered and verified for fixed service in accordance with ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR.

Free-hanging vertical run

Suitable

Engineered and verified for hanging service in accordance with ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR.

Switchgear & control cabinet wiring

Suitable

Suitable for switchgear, control panels and equipment terminations within 10 × OD bend radius.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Typical machinesBuilding & Fire SafetyCommercial & Residential Building DistributionData Centers & Public InfrastructureFire-Safe Evacuation & Riser ShaftsIndustrial Plant Balance-of-Plant WiringAutomated Assembly & Packaging Lines

Construction

Layer by layer

Shown: OFNR-144F Tight-Buffered Distribution (ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR) with dielectric strength rod, central element polymer jacket core insulation and flame-retardant outer jacket (6-layer construction).

123456
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Dielectric strength rodDielectric strength rod assembly per ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNRICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR
2Central element polymer jacket core insulationExtruded Central element polymer jacket dielectric (individual core / group layer)ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR
3Dielectric strength yarnsExtruded Dielectric strength yarns dielectric (individual core / group layer)ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR
4Flame-retardant subunit jacketExtruded Flame-retardant subunit jacket protective layer (individual core / group layer)ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR
5Dielectric strength elementsDielectric strength elements high-coverage braided layer (woven structure)ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR
6Flame-retardant outer jacketExtruded Flame-retardant outer jacket protective layer (continuous layer)ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR

OFNR-144F Tight-Buffered Distribution — Standard Execution

Built to ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR with dielectric strength rod and flame-retardant outer

OFNR-144F Tight-Buffered Distribution — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR

OFNR-144F Tight-Buffered Distribution — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
All-Dielectric Optical (ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR)
Conductor construction
Dielectric strength rod — Dielectric strength rod assembly per ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR
Primary insulation / dielectric
Central element polymer jacket core insulation — Extruded Central element polymer jacket dielectric (individual core / group layer)

Thermal

Continuous operating temperature
−20…+70 °C per ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
Flame-retardant outer jacket — Extruded Flame-retardant outer jacket protective layer (continuous layer)
Minimum bending radius
10 × OD (installed / static routing)
Layer count & geometry
6 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
OFNR-144F Tight-Buffered Distribution
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

12 standard OFNR-144F Tight-Buffered Distribution cable configurations

Manufactured to ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR in single-pair, multi-pair and multi-unit constructions.

Dimensions, construction & weights
Order designationConfigurationOuter Ø ≈
mm
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
OFNR-144F Tight-Buffered Distribution Standard Construction Schedule (All-Dielectric Optical · −20…+70 °C)
OFNR-144F Tight-Buffered Distribution 1×2×0.51×2×0.5 mm²6.45852
OFNR-144F Tight-Buffered Distribution 2×2×0.52×2×0.5 mm²9.211274
OFNR-144F Tight-Buffered Distribution 4×2×0.54×2×0.5 mm²11.417692
OFNR-144F Tight-Buffered Distribution 8×2×0.58×2×0.5 mm²14.8295118
OFNR-144F Tight-Buffered Distribution 12×2×0.512×2×0.5 mm²17.6420141
OFNR-144F Tight-Buffered Distribution 1×2×1.01×2×1.0 mm²7.68661
OFNR-144F Tight-Buffered Distribution 2×2×1.02×2×1.0 mm²11.016888
OFNR-144F Tight-Buffered Distribution 4×2×1.04×2×1.0 mm²13.5264108
OFNR-144F Tight-Buffered Distribution 8×2×1.08×2×1.0 mm²17.9465143
OFNR-144F Tight-Buffered Distribution 1×2×1.51×2×1.5 mm²8.511468
OFNR-144F Tight-Buffered Distribution 4×2×1.54×2×1.5 mm²15.2348122
OFNR-144F Tight-Buffered Distribution 12×2×1.512×2×1.5 mm²23.4860187
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Additional pair/triad/quad counts (up to 48 pairs) and blue Ex-i intrinsically safe outer sheaths available per ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR)DC resistance at 20 °C and geometry within ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR)Full compliance with ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR across −20…+70 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

ICEA S-83-596 CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX OFNR-144F Tight-Buffered Distribution <size> ICEA S-83-596 All-Dielectric Optical CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define OFNR-144F Tight-Buffered Distribution (144-core optical Multi-Subunit Tight-Buffered Riser Distribution Fiber Optic Cable)?
OFNR-144F Tight-Buffered Distribution (144-core optical Multi-Subunit Tight-Buffered Riser Distribution Fiber Optic Cable) is manufactured in accordance with ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR for All-Dielectric Optical service over -20 °C to +70 °C. Its 6-layer construction comprises dielectric strength rod, central element polymer jacket core insulation, dielectric strength yarns, flame-retardant subunit jacket, dielectric strength elements, flame-retardant outer jacket.
What is the minimum bending radius and installation temperature for OFNR-144F Tight-Buffered Distribution?
The minimum installed bending radius for OFNR-144F Tight-Buffered Distribution is 10 × OD across its continuous operating temperature range of -20 °C to +70 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of OFNR-144F Tight-Buffered Distribution arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Dielectric strength rod (Dielectric strength rod assembly per ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR); (02) Central element polymer jacket core insulation (Extruded Central element polymer jacket dielectric (individual core / group layer)); (03) Dielectric strength yarns (Extruded Dielectric strength yarns dielectric (individual core / group layer)); (04) Flame-retardant subunit jacket (Extruded Flame-retardant subunit jacket protective layer (individual core / group layer)); (05) Dielectric strength elements (Dielectric strength elements high-coverage braided layer (woven structure)); (06) Flame-retardant outer jacket (Extruded Flame-retardant outer jacket protective layer (continuous layer)).
What factory test certificates are supplied with OFNR-144F Tight-Buffered Distribution?
Every production drum or spool of OFNR-144F Tight-Buffered Distribution undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per ICEA S-83-596 / ANSI/TIA-568 / UL 1666 OFNR, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for OFNR-144F Tight-Buffered Distribution

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

OFNR-144F Tight-Buffered Distribution 144-Fiber Multi-Subunit Tight-Buffered Riser Distribution Fiber

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote