Contact

8138 120 Ohm 8-Pair 28 AWG RS-232/485 Shielded Data CableTIA/EIA-485, UL AWM Style 2919 (30 V) & NEC CL2 (300 V, 120 Ω, 12.8 pF/ft) 8-pair 28 AWG foil and 65% tinned copper braid shielded low-capacitance RS-232/485 data cable.

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

EMC screen
Low-EMC design
Flame-retardant
Approved
Order designation
8138 8 Pairs × 28 AWG (120 Ω)
Outer diameter
6.7 mm
Cable weight
58 kg/km
Min. bend radius
67 mm
Conductor & shield
7×36 AWG Tinned Cu + FPE + Foil/65% TCWB
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Impedance
120 Ω
360° shield coverage
Temperature
−20…+80 °C
Fixed / flex duty
Min. bend radius
10 × OD
6.7–7.7 mm
Screening
Foil + TC Braid
360° foil + tinned Cu braid
Outer sheath
Industrial PVC
Oil & sunlight resistant
Core / size range
3 sizes
3 standard configurations

Typical values for this cable type, based on Reference specification per TIA/EIA-485 / UL AWM 2919 / NEC CL2 (8138 120Ω RS-232/485 CL2) — confirmed in the datasheet and quotation for your order.

Application fit

Is 8138 120Ω RS-232/485 CL2 right for your machine?

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Fixed installation

Suitable

Approved for open cable tray, raceway and supported industrial runs per standard installation rules.

Switchgear & control cabinet wiring

Suitable

Controlled characteristic impedance and low mutual capacitance preserve signal eye opening over long trunks.

Energy chain / drag chain

With conditions

Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.

Offshore platform & shipboard deck trays

Suitable

Outer sheath compound resists industrial cutting fluids, mineral oils and outdoor sunlight.

Vertical / spreader reel

Not suitable

Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.

Use TRA 0.6/1 kV PUR Reeling Cable

Industrial network, bus & patch rack

Suitable

Controlled-impedance UL 1685 construction delivers low-attenuation telemetry across industrial Ethernet, fieldbus, and control racks.

Typical machinesBuilding & Fire SafetyIndustrial automation & control cabinetsInverter-fed motor drive systemsProcess instrumentation & oil/gas skidsMachine tools & robotic cellsData centers, stadiums & broadcast facilities

Construction

Layer by layer

Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

8138 120Ω RS-232/485 CL2 – Layered cable cutaway
Layer cutaway
#LayerMaterial & reference
18 Twisted Pairs (28 AWG Tinned Copper)7×36 AWG Stranded Tinned Copper (16 Conductors)
2Foam Polyethylene (FPE) Core InsulationLow-Capacitance 12.8 pF/ft Color-Coded FPE
3100% Aluminum/Polyester Foil + Drain WireOverall Foil Tape Shield + 24 AWG Tinned Cu Drain
465% Tinned Copper Wire Braid ShieldOverall Braided Tinned Copper EMI Screen
5Chrome Grey Industrial PVC Outer JacketUL AWM Style 2919 (30V) / NEC CL2 (300V) Sheath (6.65 mm OD)

8 × 2 × 28 AWG (0.089 mm²)

7×36 AWG Tinned Cu + FPE + Foil/65% TCWB · Outer diameter 6.65 mm.

5 × 2 × 28 AWG (0.089 mm²)

7×36 AWG Tinned Cu + FPE + Foil/65% TCWB · Outer diameter 5.84 mm.

12 × 2 × 28 AWG (0.089 mm²)

7×36 AWG Tinned Cu + FPE + Foil/65% TCWB · Outer diameter 7.72 mm.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on Reference specification per TIA/EIA-485 / UL AWM 2919 / NEC CL2 (8138 120Ω RS-232/485 CL2). Values for your order are confirmed in the datasheet and quotation.

Electrical

Nominal / reference voltage
30 V AWM 2919 / 300 V CL2
Conductor & core insulation
7×36 AWG Stranded Tinned Copper (16 Conductors) · Low-Capacitance 12.8 pF/ft Color-Coded FPE
Routine dielectric / continuity test
100% factory drum spark & continuity verified

Thermal

Operating temperature range
−20…+80 °C
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s conductor thermal limit)
Flame & fire performance
TIA/EIA-485 / UL AWM 2919 / NEC CL2

Mechanical

Minimum bending radius
10 × OD
Screening / armour architecture
Overall Foil Tape Shield + 24 AWG Tinned Cu Drain · Overall Braided Tinned Copper EMI Screen
Outer sheath material & colour
UL AWM Style 2919 (30V) / NEC CL2 (300V) Sheath (6.65 mm OD)

Reference standards

Reference standard
TIA/EIA-485 / TIA/EIA-232 / UL AWM Style 2919 (30V) / NEC CL2 (300V) / UL 1685
Hazardous Substance Compliance
CE, RoHS 2 (2011/65/EU) & REACH SVHC compliant
Quality & Batch Traceability
EN 10204 3.1 Factory Inspection Certificate

Sizes

Sizes & engineering data

Representative configurations from the series specification; select a row to prefill the quotation tool.

All sizes
ConfigurationConductor & shieldInsulation / wallOuter sheathOuter diameter
mm
Min. bend radius
mm
Max. conductor resistance @ 20 °C
Ω/km
Copper weight
kg/km
Cable weight
kg/km
Key electrical / optical ratingPart designationEnquiry
8138 120Ω RS-232/485 CL2
8 × 2 × 28 AWG (0.089 mm²)7×36 AWG Tinned Cu + FPE + Foil/65% TCWBLow-Capacitance 12.8 pF/ft Color-Coded FPEIndustrial PVC6.767213.0024.558120 Ω · 42.0 pF/m (12.8 pF/ft) · 78% VP8138 8 Pairs × 28 AWG (120 Ω)
5 × 2 × 28 AWG (0.089 mm²)7×36 AWG Tinned Cu + FPE + Foil/65% TCWBLow-Capacitance 12.8 pF/ft Color-Coded FPEIndustrial PVC5.858213.0018.245120 Ω · 42.0 pF/m (12.8 pF/ft) · 78% VP8135 5 Pairs × 28 AWG (120 Ω)
12 × 2 × 28 AWG (0.089 mm²)7×36 AWG Tinned Cu + FPE + Foil/65% TCWBLow-Capacitance 12.8 pF/ft Color-Coded FPEIndustrial PVC7.777213.0033.879120 Ω · 42.0 pF/m (12.8 pF/ft) · 78% VP8142 12 Pairs × 28 AWG (120 Ω)
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Dimensions and weights are nominal manufacturing targets subject to standard production tolerances.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance & continuityWithin maximum Ω/km limit at 20 °CEvery manufactured drum length
Dielectric withstand / spark testNo breakdown across insulation or shieldEvery manufactured drum length
Sample tests
Vertical flame propagation & jacket qualificationSelf-extinguishing within standard char limitType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

TIA/EIA-485 / UL AWM 2919 / NEC CL2 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX 8138 120Ω RS-232/485 CL2 TIA/EIA-485 / UL AWM 2919 / NEC CL2 30 V AWM 2919 / 300 V CL2 CE ROHS — sequential metre marking
Delivery form
Heavy-duty export fumigated wooden drums or steel reels with moisture-sealed ends
Standard lengths
305 m, 500 m, 1000 m continuous drum lengths or custom cut-to-length runs
MOQ
100 m (standard configurations) · 300 m (custom builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-03
Updated
2026-11-03

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is 8138 120Ω RS-232/485 CL2 designed for?
8138 120Ω RS-232/485 CL2 is engineered for industrial installations under TIA/EIA-485 / UL AWM 2919 / NEC CL2, operating over −20…+80 °C with a minimum bending radius of 10 × OD.
How does the construction of 8138 120Ω RS-232/485 CL2 protect signal and power integrity?
Its multi-layer build combines 8 Twisted Pairs (28 AWG Tinned Copper) with Foam Polyethylene (FPE) Core Insulation and Chrome Grey Industrial PVC Outer Jacket to ensure mechanical stability and electrical performance.
What standards and fire ratings apply to 8138 120Ω RS-232/485 CL2?
The cable is qualified to TIA/EIA-485 / TIA/EIA-232 / UL AWM Style 2919 (30V) / NEC CL2 (300V) / UL 1685, meeting vertical flame propagation and industrial jacket durability requirements.
Can 8138 120Ω RS-232/485 CL2 be supplied in custom lengths or configurations?
Yes. Standard configurations include 8138 8 Pairs × 28 AWG (120 Ω), 8135 5 Pairs × 28 AWG (120 Ω) and 8142 12 Pairs × 28 AWG (120 Ω), supplied on 305 m, 500 m or 1,000 m export drums.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for 8138 120Ω RS-232/485 CL2

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

8138 120Ω RS-232/485 CL2 8138 120 Ohm 8-Pair 28 AWG RS-232/485 Shielded Data Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote