Fixed installation
Approved for open cable tray, raceway and supported industrial runs per standard installation rules.
Product
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Typical values for this cable type, based on Reference specification per UL 1277 TC-ER-LS / UL 1685 Limited Smoke (29504T Series 600/1000V TC-ER-LS LSZH) — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Approved for open cable tray, raceway and supported industrial runs per standard installation rules.
Low-impedance shielding contains high-frequency common-mode currents and dV/dt voltage spikes.
Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.
Low-smoke zero-halogen outer sheath minimizes toxic acid gas emission and smoke obscuration in fire events.
Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.
Use TRA 0.6/1 kV PUR Reeling CableDurable 000 V XLPE/LSZH construction powers industrial process pumps, boosters, and compressor skids under continuous plant duty.
Construction
Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

| # | Layer | Material & reference |
|---|---|---|
| 1 | 4×8 AWG (7×19×29) Tinned Copper (3P+G) | 7×19×29 AWG (133 Strands) Tinned Copper (3 Phase + 1 Full GND) |
| 2 | Heavy-Wall Cross-Linked Polyethylene (XLPE) | 1.32mm Corona-Resistant XLPE (3 Black Numbered + 1 G/Y) |
| 3 | Halogen-Free Tape + 100% Foil + 85% TC Braid | Halogen-Free Binder + Foil + 85% Tinned Cu Braid + Drains |
| 4 | Black Thermoset Low-Smoke Zero-Halogen Jacket | UL 1277 TC-ER-LS Halogen-Free Flame-Retardant Sheath (23.62 mm OD) |
7×19×29 AWG Tinned Cu + 1.32mm XLPE + Foil/85% TCWB + LSZH · Outer diameter 23.62 mm.
65×30 AWG Tinned Cu + XLPE + Foil/85% TCWB + LSZH · Outer diameter 15.04 mm.
105×30 AWG Tinned Cu + XLPE + Foil/85% TCWB + LSZH · Outer diameter 17.27 mm.
Technical data
Sizes
Representative configurations from the series specification; select a row to prefill the quotation tool.
| Configuration | Conductor & shield | Insulation / wall | Outer sheath | Outer diameter mm | Min. bend radius mm | Max. conductor resistance @ 20 °C Ω/km | Copper weight kg/km | Cable weight kg/km | Key electrical / optical rating | Part designation | Enquiry |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 29504T Series 600/1000V TC-ER-LS LSZH | |||||||||||
| 4 × 8 AWG (8.37 mm² · 7×19×29 AWG) | 7×19×29 AWG Tinned Cu + 1.32mm XLPE + Foil/85% TCWB + LSZH | 1.32mm Corona-Resistant XLPE (3 Black Numbered + 1 G/Y) | LSZH Jacket | 23.6 | 236 | 2.14 | 425.0 | 765 | 600/1,000 V TC-ER-LS (55 A · Halogen-Free) | 29504T 4G8 AWG (3×8+1×8 G/Y) TC-ER-LS | |
| 4 × 12 AWG (3.31 mm² · 65×30 AWG) | 65×30 AWG Tinned Cu + XLPE + Foil/85% TCWB + LSZH | 1.32mm Corona-Resistant XLPE (3 Black Numbered + 1 G/Y) | LSZH Jacket | 15.0 | 150 | 5.41 | 176.0 | 338 | 600/1,000 V TC-ER-LS (30 A · Halogen-Free) | 29502T 4G12 AWG (3×12+1×12 G/Y) TC-ER-LS | |
| 4 × 10 AWG (5.26 mm² · 105×30 AWG) | 105×30 AWG Tinned Cu + XLPE + Foil/85% TCWB + LSZH | 1.32mm Corona-Resistant XLPE (3 Black Numbered + 1 G/Y) | LSZH Jacket | 17.3 | 173 | 3.41 | 268.0 | 468 | 600/1,000 V TC-ER-LS (40 A · Halogen-Free) | 29503T 4G10 AWG (3×10+1×10 G/Y) TC-ER-LS | |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & continuity | Within maximum Ω/km limit at 20 °C | Every manufactured drum length |
| Dielectric withstand / spark test | No breakdown across insulation or shield | Every manufactured drum length |
| Sample tests | ||
| Vertical flame propagation & jacket qualification | Self-extinguishing within standard char limit | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.