Fixed installation
Individually and/or collectively screened pairs and cores reject electrostatic and electromagnetic interference in high-EMC marine zones.
Product
BFOU(i) (TCWB) & BFCU(i) (GSWB) 150/250 V NEK TS 606 Fire- & Mud-Resistant Offshore Instrument Cable (NEK TS 606 / IEC 60092-376 BFOU(i)) engineered for 150/250 V (300 V) service across -40 to +90 °C (min. bend radius 8 × OD).
Typical values for this cable type, based on NEK TS 606 Code S3/S7 BFOU(i) & BFCU(i) 150/250 V IEC 60331 Fire-Resistant SHF2-MUD Specification — confirmed in the datasheet and quotation for your order.
Application fit
BFOU(i) (TCWB) & BFCU(i) (GSWB) 150/250 V NEK TS 606 Fire- & Mud-Resistant Offshore Instrument Cable (NEK TS 606 / IEC 60092-376 BFOU(i)) engineered for 150/250 V (300 V) service across -40 to +90 °C (min. bend radius 8 × OD).
Individually and/or collectively screened pairs and cores reject electrostatic and electromagnetic interference in high-EMC marine zones.
SHF2-MUD or IEEE 1580 Type P outer sheath resists drilling mud, ester fluids, hydrocarbons, salt spray and UV exposure.
Compact twisted pairs and numbered cores route cleanly into DCS/PLC cabinets, Ex-i barriers, sonar racks and bridge consoles.
Tinned copper, bronze or galvanized steel wire braid armour protects signal integrity in hazardous offshore zones.
Fixed shipboard and offshore instrumentation cable is not intended for high-speed crane festoon loops.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: BFOU(i) / BFCU(i) 250V (NEK TS 606 Code S3/S7 BFOU(i) & BFCU(i) 150/250 V IEC 60331 Fire-Resistant SHF2-MUD Specification) featuring mica + epr/xlpe twisted pairs (0.75-2.5 mm²), cu/pet or al/pet individual & collective screen and shf2-mud fire & mud-resistant outer jacket (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Mica + EPR/XLPE Twisted Pairs (0.75-2.5 | Tinned copper conductors with mica fire barrier and EPR/XLPE insulation |
| 2 | Cu/PET or Al/PET Individual & Collective | Metallic foil tape + tinned copper drain wire on each pair/triad |
| 3 | TCWB (BFOU) / GSWB (BFCU) Braid Armour | Tinned copper wire braid (O) or galvanized steel wire braid (C) |
| 4 | SHF2-MUD Fire & Mud-Resistant Outer Jack | Cross-linked low-smoke zero-halogen mud-resistant thermoset sheath |
Built to NEK TS 606 Code S3/S7 BFOU(i) & BFCU(i) 150/250 V IEC 60331 Fire-Resistant SHF2-MUD Specification with mica + epr/xlpe twisted pairs (0.75-2.5 mm²) and shf2-mud fire & mud-resistant outer jacket
Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations
Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report
Technical data
Sizes
Manufactured to NEK TS 606 Code S3/S7 BFOU(i) & BFCU(i) 150/250 V IEC 60331 Fire-Resistant SHF2-MUD Specification for subsea, oceanographic, ROV, seismic and offshore applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Breaking / tensile kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| BFOU(i) / BFCU(i) 250V Construction Schedule (−40…+90 °C) | |||||||
| BFOU 4Pr / 8Ch | 4×2×24–20 AWG (or 8-Ch Array) | Stranded SnCu + Foil/Braid + Aramid | 11.2 | 175 | 12.5 | 90 | |
| BFOU 8Pr / 16Ch | 8×2×22–18 AWG (or 16-Ch Array) | Stranded SnCu + Foil/Braid + Aramid | 16.4 | 340 | 24.0 | 130 | |
| BFOU 16Pr / 24Ch | 16×2×18–16 AWG (or 24-Ch Array) | Stranded SnCu + Foil/Braid + Aramid | 24.8 | 690 | 35.0 | 195 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24–20 AWG (or 8-Ch Array) | 42.00 | 150/250 V (300 V) (≤55 nF/km) | −40…+90 °C |
| 8×2×22–18 AWG (or 16-Ch Array) | 26.00 | 150/250 V (300 V) (≤60 nF/km) | −40…+90 °C |
| 16×2×18–16 AWG (or 24-Ch Array) | 15.20 | 150/250 V (300 V) (≤65 nF/km) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, optical OTDR continuity & dimensional verification (NEK TS 606 Code S3/S7 BFOU(i) & BFCU(i) 150/250 V IEC 60331 Fire-Resistant SHF2-MUD Specification) | DC resistance at 20 °C / optical attenuation and outer diameter within NEK TS 606 Code S3/S7 BFOU(i) & BFCU(i) 150/250 V IEC 60331 Fire-Resistant SHF2-MUD Specification tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (NEK TS 606 Code S3/S7 BFOU(i) & BFCU(i) 150/250 V IEC 60331 Fire-Resistant SHF2-MUD Specification) | Zero dielectric breakdown and verified insulation resistance for 150/250 V (300 V) rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile breaking load & water-blocking qualification (NEK TS 606 Code S3/S7 BFOU(i) & BFCU(i) 150/250 V IEC 60331 Fire-Resistant SHF2-MUD Specification) | Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.