Fixed installation
Water-blocked loose-tube or slotted-core construction protects OS2 single-mode and OM3/OM4 multimode fibres on vessels.
Product
QFCI & QFCU NEK TS 606 F101 Fire-Resistant GSWB-Armoured Offshore Backbone Fiber Optic Cable (NEK TS 606 F101 / IEC 60331-25) engineered for Optical service across -40 to +85 °C (min. bend radius 12 × OD).
Typical values for this cable type, based on NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794 — confirmed in the datasheet and quotation for your order.
Application fit
QFCI & QFCU NEK TS 606 F101 Fire-Resistant GSWB-Armoured Offshore Backbone Fiber Optic Cable (NEK TS 606 F101 / IEC 60331-25) engineered for Optical service across -40 to +85 °C (min. bend radius 12 × OD).
Water-blocked loose-tube or slotted-core construction protects OS2 single-mode and OM3/OM4 multimode fibres on vessels.
Copper or galvanized steel wire braid armour and SHF1/SHF2-MUD jacket resist crush, rodents, oil and drilling mud.
IEC 60331-25 fire-resistant mica-protected execution maintains optical data continuity during offshore fire emergencies.
All-dielectric FRP central strength member and colour-coded fibres simplify splicing into marine patch panels.
Fixed shipboard and offshore backbone optical cable is not intended for dynamic deepwater ROV lift winches.
Use FXMSU / LKSM-FO Marine Optical CableConstruction
Shown: QFCI & QFCU (NEK 606 F101) (NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794) featuring central frp dielectric strength member, mica-protected gel-filled loose tubes (4×6f) and shf2-mud offshore outer jacket (code f101) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Central FRP Dielectric Strength Member | Non-metallic glass-fibre reinforced plastic central rod |
| 2 | Mica-Protected Gel-Filled Loose Tubes (4 | PBT loose tubes wrapped with mica fire tape (IEC 60331-25) |
| 3 | Aramid Yarn & SHF1/SHF2 Inner Sheath | High-tensile aramid yarns + halogen-free flame-retardant inner jacket |
| 4 | Galvanized Steel Wire Braid Armour (QFCI | High-coverage galvanized steel wire braid armour |
| 5 | SHF2-MUD Offshore Outer Jacket (Code F10 | Mud-, oil- and fire-resistant thermoset outer sheath (NEK TS 606) |
Built to NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794 with central frp dielectric strength member and shf2-mud offshore outer jacket (code f101)
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794 for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| QFCI & QFCU (NEK 606 F101) Construction Schedule (−40…+85 °C) | |||||||
| QFCI & QFCU 4F OS2 / OM3 | 4 × 9/125 µm OS2 or 50/125 µm OM3 | Armoured marine optical core | 10.6 | 155 | 2.2 | 110 | |
| QFCI & QFCU 12F OS2 / OM4 | 12 × 9/125 µm OS2 or 50/125 µm OM4 | Armoured marine optical core | 12.8 | 235 | 3.0 | 130 | |
| QFCI & QFCU 24F OS2 / OM4 | 24 × 9/125 µm OS2 or 50/125 µm OM4 | Armoured marine optical core | 15.4 | 345 | 4.2 | 155 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4 × 9/125 µm OS2 or 50/125 µm OM3 | 0.35 | ≤0.35 dB/km @ 1310 nm | −40…+85 °C |
| 12 × 9/125 µm OS2 or 50/125 µm OM4 | 0.22 | ≤0.22 dB/km @ 1550 nm | −40…+85 °C |
| 24 × 9/125 µm OS2 or 50/125 µm OM4 | 0.20 | ≤0.20 dB/km @ 1550 nm | −40…+85 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794) | DC resistance at 20 °C / optical attenuation and outer diameter within NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794) | Zero dielectric breakdown and verified insulation resistance for Optical rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+85 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.