Contact
armoured marine & offshore optical cableNEK TS 606 F101 / IEC 60331-25Optical (-40 to +85 °C)SHF2-MUD Offshore Outer Jacket (Code

QFCI & QFCU NEK TS 606 F101 Fire-Resistant GSWB-Armoured Offshore Backbone Fiber Optic CableNEK TS 606 F101 / IEC 60331-25 — Optical — -40 to +85 °C Marine & Offshore Cable

QFCI & QFCU NEK TS 606 F101 Fire-Resistant GSWB-Armoured Offshore Backbone Fiber Optic Cable (NEK TS 606 F101 / IEC 60331-25) engineered for Optical service across -40 to +85 °C (min. bend radius 12 × OD).

Flame-retardant
Ozone, UV & moisture
Oil-resistant
Approved
Order designation
QFCI & QFCU 4F OS2 / OM3
Outer Ø ≈
10.6 mm
Net weight ≈
155 kg/km
Tensile rating ≈
2.2 kN
Core / stranding
Armoured marine optical core
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
Optical
Tested per NEK TS 606 F101 / IEC 60331-2
Operating temp.
−40…+85 °C
Continuous shipboard & offshore service
Min. bend radius
12 × OD
Marine tray, bulkhead & deck routing
Core / conductor
Central FRP Diel
Non-metallic glass-fibre reinforced plas
Outer protection
SHF2-MUD Offshor
Mud-, oil- and fire-resistant thermoset
Standard
NEK TS 606 F101
NEK TS 606 Code F101 & IEC 60331-25 (750

Typical values for this cable type, based on NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794 — confirmed in the datasheet and quotation for your order.

Application fit

Is QFCI & QFCU (NEK 606 F101) right for your machine?

QFCI & QFCU NEK TS 606 F101 Fire-Resistant GSWB-Armoured Offshore Backbone Fiber Optic Cable (NEK TS 606 F101 / IEC 60331-25) engineered for Optical service across -40 to +85 °C (min. bend radius 12 × OD).

Fixed installation

Suitable

Water-blocked loose-tube or slotted-core construction protects OS2 single-mode and OM3/OM4 multimode fibres on vessels.

Offshore platform & shipboard deck trays

Suitable

Copper or galvanized steel wire braid armour and SHF1/SHF2-MUD jacket resist crush, rodents, oil and drilling mud.

Drilling jumbo & rotary mast feed

Suitable

IEC 60331-25 fire-resistant mica-protected execution maintains optical data continuity during offshore fire emergencies.

Switchgear & control cabinet wiring

Suitable

All-dielectric FRP central strength member and colour-coded fibres simplify splicing into marine patch panels.

Typical machinesBuilding & Fire SafetyOffshore Platform & FPSO Optical BackbonesShipboard Integrated Bridge & IT NetworksFire-Safe ESD, CCTV & Telecom LinksLNG Carrier & Drillship Process Control

Construction

Layer by layer

Shown: QFCI & QFCU (NEK 606 F101) (NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794) featuring central frp dielectric strength member, mica-protected gel-filled loose tubes (4×6f) and shf2-mud offshore outer jacket (code f101) (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Central FRP Dielectric Strength MemberNon-metallic glass-fibre reinforced plastic central rod
2Mica-Protected Gel-Filled Loose Tubes (4PBT loose tubes wrapped with mica fire tape (IEC 60331-25)
3Aramid Yarn & SHF1/SHF2 Inner SheathHigh-tensile aramid yarns + halogen-free flame-retardant inner jacket
4Galvanized Steel Wire Braid Armour (QFCIHigh-coverage galvanized steel wire braid armour
5SHF2-MUD Offshore Outer Jacket (Code F10Mud-, oil- and fire-resistant thermoset outer sheath (NEK TS 606)

QFCI & QFCU (NEK 606 F101) — Standard Shipboard & Offshore Execution

Built to NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794 with central frp dielectric strength member and shf2-mud offshore outer jacket (code f101)

QFCI & QFCU (NEK 606 F101) — Custom Drum Length & Gland Kit

Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands

QFCI & QFCU (NEK 606 F101) — Class & Routine Test Certified

Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
Optical (NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794)
Core / conductor construction
Central FRP Dielectric Strength Member — Non-metallic glass-fibre reinforced plastic central rod
Primary dielectric / buffering
Mica-Protected Gel-Filled Loose Tubes (4×6F) — PBT loose tubes wrapped with mica fire tape (IEC 60331-25)

Thermal

Continuous operating temperature
−40…+85 °C (shipboard & offshore duty)
Short-circuit / peak thermal rating
Verified thermal stability per NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
SHF2-MUD Offshore Outer Jacket (Code F101) — Mud-, oil- and fire-resistant thermoset outer sheath (NEK TS 606)
Minimum bending radius
12 × OD
Armour, screen & mechanical duty
Galvanized Steel Wire Braid Armour (QFCI) — High-coverage galvanized steel wire braid armour

Resistance

Flame, fire & smoke performance
Qualified for marine flame-retardance and low-smoke zero-halogen / fire safety per NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794
Oil, drilling mud & seawater resistance
Resistant to marine fuel/lube oils, salt mist and offshore fluids per NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794
Environmental & test standards
IEC 60228 / IEC 60332-3-22 / IEC 60754 / IEC 61034 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
QFCI & QFCU (NEK 606 F101)
Sheath colour & metre marking
Continuous metre-marked black outer finish (SHF2-MUD Offshor)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard QFCI & QFCU (NEK 606 F101) shipboard & offshore configurations

Manufactured to NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794 for shipboard, offshore platform, drilling rig and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
QFCI & QFCU (NEK 606 F101) Construction Schedule (−40…+85 °C)
QFCI & QFCU 4F OS2 / OM34 × 9/125 µm OS2 or 50/125 µm OM3Armoured marine optical core10.61552.2110
QFCI & QFCU 12F OS2 / OM412 × 9/125 µm OS2 or 50/125 µm OM4Armoured marine optical core12.82353.0130
QFCI & QFCU 24F OS2 / OM424 × 9/125 µm OS2 or 50/125 µm OM4Armoured marine optical core15.43454.2155
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794)DC resistance at 20 °C / optical attenuation and outer diameter within NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794 tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794)Zero dielectric breakdown and verified insulation resistance for Optical ratingEvery manufactured drum length
Sample tests
Flame, fire integrity, oil/mud & mechanical qualification (NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794)Verified flame/fire performance, fluid resistance and thermal stability across −40…+85 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

NEK TS 606 F101 / IEC 60331-25 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX QFCI & QFCU (NEK 606 F101) NEK TS 606 F101 / IEC 60331-25 Optical CE
Delivery form
Heavy-duty export fumigated wooden drums or steel marine reels
Standard lengths
500 m, 1,000 m or custom continuous shipboard/offshore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define QFCI & QFCU (NEK 606 F101) (QFCI & QFCU NEK TS 606 F101 Fire-Resistant GSWB-Armoured Offshore Backbone Fiber Optic Cable)?
QFCI & QFCU (NEK 606 F101) (QFCI & QFCU NEK TS 606 F101 Fire-Resistant GSWB-Armoured Offshore Backbone Fiber Optic Cable) is manufactured in accordance with NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794 for Optical service over -40 to +85 °C. Its 5-layer construction comprises central frp dielectric strength member, mica-protected gel-filled loose tubes (4×6f) and shf2-mud offshore outer jacket (code f101).
What is the minimum bending radius and operating temperature range for QFCI & QFCU (NEK 606 F101)?
The minimum bending radius for QFCI & QFCU (NEK 606 F101) is 12 × OD across its continuous operating temperature range of -40 to +85 °C, ensuring mechanical and dielectric reliability in shipboard and offshore service.
How are the concentric layers of QFCI & QFCU (NEK 606 F101) arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Central FRP Dielectric Strength Member — Non-metallic glass-fibre reinforced plastic central rod; (02) Mica-Protected Gel-Filled Loose Tubes (4×6F) — PBT loose tubes wrapped with mica fire tape (IEC 60331-25); (03) Aramid Yarn & SHF1/SHF2 Inner Sheath — High-tensile aramid yarns + halogen-free flame-retardant inner jacket; (04) Galvanized Steel Wire Braid Armour (QFCI) — High-coverage galvanized steel wire braid armour; (05) SHF2-MUD Offshore Outer Jacket (Code F101) — Mud-, oil- and fire-resistant thermoset outer sheath (NEK TS 606).
What factory test certificates are supplied with QFCI & QFCU (NEK 606 F101)?
Every production drum of QFCI & QFCU (NEK 606 F101) undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per NEK TS 606 Code F101 & IEC 60331-25 (750–850 °C Fire Integrity) / IEC 60794, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for QFCI & QFCU (NEK 606 F101)

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

QFCI & QFCU NEK TS 606 F101 Fire-Resistant GSWB-Armoured Offshore Backbone Fiber Optic Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote