Fixed installation
Approved for open cable tray, raceway and supported industrial runs per standard installation rules.
Product
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Typical values for this cable type, based on Reference specification per IEC 61196-4 / EN 50117 (RA500 50Ω 1/2" DAS Coax) — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Approved for open cable tray, raceway and supported industrial runs per standard installation rules.
Controlled characteristic impedance and low mutual capacitance preserve signal eye opening over long trunks.
Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.
Outer sheath compound resists industrial cutting fluids, mineral oils and outdoor sunlight.
Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.
Use TRA 0.6/1 kV PUR Reeling CableMoisture-resistant IEC 60332-1-2 insulation maintains dielectric integrity along underground airfield runway AGL series loops.
Construction
Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

| # | Layer | Material & reference |
|---|---|---|
| 1 | Copper-Clad Aluminum Inner Conductor | 4.80 mm Solid CCA Center Conductor |
| 2 | Closed-Cell Physical Foam PE Dielectric | 12.30 mm Low-Loss Nitrogen-Foamed Polyethylene |
| 3 | Annular Corrugated Copper Outer Conductor | 13.80 mm 100% RF-Sealed Corrugated Copper Tube |
| 4 | UV-Resistant Black PE Outer Jacket | 16.00 mm Weatherproof Polyethylene Sheath |
4.80 mm CCA + Foam PE + Corrugated Cu Tube · Outer diameter 16 mm.
4.80 mm CCA + Foam PE + Corrugated Cu Tube · Outer diameter 16 mm.
3.60 mm CCA + Foam PE + Helical Corrugated Cu · Outer diameter 13.6 mm.
Technical data
Sizes
Representative configurations from the series specification; select a row to prefill the quotation tool.
| Configuration | Conductor & shield | Insulation / wall | Outer sheath | Outer diameter mm | Min. bend radius mm | Max. conductor resistance @ 20 °C Ω/km | Copper weight kg/km | Cable weight kg/km | Key electrical / optical rating | Part designation | Enquiry |
|---|---|---|---|---|---|---|---|---|---|---|---|
| RA500 50Ω 1/2" DAS Coax | |||||||||||
| 1/2" (4.80 / 12.30 / 13.80 / 16.00 mm) | 4.80 mm CCA + Foam PE + Corrugated Cu Tube | 12.30 mm Low-Loss Nitrogen-Foamed Polyethylene | Outdoor PE | 16.0 | 125 | 1.48 | 118.0 | 225 | 50 ± 1 Ω · 76 pF/m · 88% VP | RA500 1/2" Standard Outdoor Black PE | |
| 1/2" (4.80 / 12.30 / 13.80 / 16.00 mm) | 4.80 mm CCA + Foam PE + Corrugated Cu Tube | 12.30 mm Low-Loss Nitrogen-Foamed Polyethylene | Outdoor PE | 16.0 | 125 | 1.48 | 118.0 | 255 | 50 ± 1 Ω · 76 pF/m · 6.9 dB/100m @ 900 MHz | RA500-LSZH 1/2" Indoor/Tunnel Flame-Retardant | |
| 1/2" Superflex (3.60 / 9.00 / 12.20 / 13.60 mm) | 3.60 mm CCA + Foam PE + Helical Corrugated Cu | 12.30 mm Low-Loss Nitrogen-Foamed Polyethylene | Outdoor PE | 13.6 | 50 | 2.65 | 96.0 | 185 | 50 ± 1 Ω · 80 pF/m · 83% VP | RA500-SF 1/2" Superflexible Helical Corrugated | |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & continuity | Within maximum Ω/km limit at 20 °C | Every manufactured drum length |
| Dielectric withstand / spark test | No breakdown across insulation or shield | Every manufactured drum length |
| Sample tests | ||
| Vertical flame propagation & jacket qualification | Self-extinguishing within standard char limit | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.