Fixed installation
Laser-welded stainless-steel / copper-tube FIMT or water-blocked loose-tube construction protects ITU-T G.652D / G.654E / OM3/OM4 fibres.
Product
QFCU 4–48F NEK TS 606 & IEC 60331-25 Fire- & Mud-Resistant Steel-Braid Armoured Marine FO Cable (NEK TS 606 / IEC 60331-25) engineered for Optical service across -40 to +90 °C (min. bend radius 12 × OD).
Typical values for this cable type, based on NEK TS 606 QFCU SHF2-MUD & IEC 60331-25 Fire-Resistant Armoured Offshore Optical Specification — confirmed in the datasheet and quotation for your order.
Application fit
QFCU 4–48F NEK TS 606 & IEC 60331-25 Fire- & Mud-Resistant Steel-Braid Armoured Marine FO Cable (NEK TS 606 / IEC 60331-25) engineered for Optical service across -40 to +90 °C (min. bend radius 12 × OD).
Laser-welded stainless-steel / copper-tube FIMT or water-blocked loose-tube construction protects ITU-T G.652D / G.654E / OM3/OM4 fibres.
Hermetic metallic optical tube, steel vault and high-density PE/PUR serving withstand up to 8,000 m deep-ocean hydrostatic pressure.
Galvanized steel or bronze wire armour and SHF2-MUD / PUR / PE jacket resist seabed abrasion, fishing-gear impact, oil and drilling mud.
NEK 606 QFCU and IEEE 1580 S670T executions maintain high-speed optical telemetry across hazardous offshore topside zones.
Submarine and armoured offshore optical cable is not intended for indoor factory automation drag chains.
Use Deepwater ROV Optical TetherConstruction
Shown: QFCU NEK 606 FO (NEK TS 606 QFCU SHF2-MUD & IEC 60331-25 Fire-Resistant Armoured Offshore Optical Specification) featuring mica-protected gel-filled loose tubes (4–48f), lszh inner bedding sheath and shf2 oil & mud-resistant outer sheath (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Mica-Protected Gel-Filled Loose Tubes (4 | PBT loose tubes wrapped with fire-resistant mica tape (IEC 60331-25) |
| 2 | LSZH Inner Bedding Sheath | Halogen-free flame-retardant inner protective jacket |
| 3 | Galvanized Steel Wire Braid (GSWB) | High-coverage galvanized steel wire braid armour |
| 4 | SHF2 Oil & Mud-Resistant Outer Sheath | Cross-linked low-smoke zero-halogen SHF2 offshore jacket |
Built to NEK TS 606 QFCU SHF2-MUD & IEC 60331-25 Fire-Resistant Armoured Offshore Optical Specification with mica-protected gel-filled loose tubes (4–48f) and shf2 oil & mud-resistant outer sheath
Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations
Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report
Technical data
Sizes
Manufactured to NEK TS 606 QFCU SHF2-MUD & IEC 60331-25 Fire-Resistant Armoured Offshore Optical Specification for subsea, oceanographic, ROV, seismic and offshore applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Breaking / tensile kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| QFCU NEK 606 FO Construction Schedule (−40…+90 °C) | |||||||
| QFCU NEK 606 FO 4–12F EOM/Sub | 4–12 × ITU-T G.652D / G.654E SM (+ Power) | Laser-welded SS FIMT + Steel/Aramid Armour | 8.2 | 260 | 48.0 | 125 | |
| QFCU NEK 606 FO 24–48F EOM/Sub | 24–48 × ITU-T G.652D / G.654E SM (+ Power) | Laser-welded SS FIMT + Contra-Helical Steel | 17.5 | 680 | 120.0 | 260 | |
| QFCU NEK 606 FO 96–192F Trunk | 96–192 × ITU-T G.654E / G.652D Submarine | SS Tube + Steel Vault + Cu Tube + DA Armour | 28.0 | 1,650 | 300.0 | 420 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4–12 × ITU-T G.652D / G.654E SM (+ Power) | 0.35 | ≤0.35 dB/km @ 1310 nm | −40…+90 °C |
| 24–48 × ITU-T G.652D / G.654E SM (+ Power) | 0.21 | ≤0.21 dB/km @ 1550 nm | −40…+90 °C |
| 96–192 × ITU-T G.654E / G.652D Submarine | 0.18 | ≤0.18 dB/km @ 1550 nm | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, optical OTDR continuity & dimensional verification (NEK TS 606 QFCU SHF2-MUD & IEC 60331-25 Fire-Resistant Armoured Offshore Optical Specification) | DC resistance at 20 °C / optical attenuation and outer diameter within NEK TS 606 QFCU SHF2-MUD & IEC 60331-25 Fire-Resistant Armoured Offshore Optical Specification tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (NEK TS 606 QFCU SHF2-MUD & IEC 60331-25 Fire-Resistant Armoured Offshore Optical Specification) | Zero dielectric breakdown and verified insulation resistance for Optical rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile breaking load & water-blocking qualification (NEK TS 606 QFCU SHF2-MUD & IEC 60331-25 Fire-Resistant Armoured Offshore Optical Specification) | Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.