Fixed installation
Mica glass-fibre fire barrier or ceramifying silicone insulation maintains circuit integrity during 750–1,100 °C fire exposure.
Product
CJ86/NC & CJ86/SC 0.6/1 kV & CHJ86/NC (CH86/NC) 150/250 V Mica-Tape + XLPE Insulated Tinned-Copper-Braid Armoured SHF1 Fire-Resistant & Flame-Retardant Shipboard Cable (IEC 60092-353 / IEC 60331, 0.6/1 kV, -40 to +90 °C).
Typical values for this cable type, based on IEC 60092-353 / IEC 60331-21 / IEC 60332-3-22 Cat. A — confirmed in the datasheet and quotation for your order.
Application fit
CJ86/NC & CJ86/SC 0.6/1 kV & CHJ86/NC (CH86/NC) 150/250 V Mica-Tape + XLPE Insulated Tinned-Copper-Braid Armoured SHF1 Fire-Resistant & Flame-Retardant Shipboard Cable (IEC 60092-353 / IEC 60331, 0.6/1 kV, -40 to +90 °C).
Mica glass-fibre fire barrier or ceramifying silicone insulation maintains circuit integrity during 750–1,100 °C fire exposure.
Low-smoke zero-halogen SHF1/SHF2/SW4 sheath minimizes toxic gas and smoke opacity during marine evacuation.
Metallic wire braid armour resists mechanical shock, water spray (+WSR) and water jet (+WJR) firefighting impact.
Terminates directly into emergency switchboards, fire-alarm panels, PA/GA systems and watertight glands.
Mica-taped fire-resistant shipboard cable is designed for fixed installation, not continuous reeling drums.
Use HVSC Shore Power Reeling CableConstruction
Shown: CJ86/NC & CJ86/SC 0.6/1 KV & CHJ86/NC (IEC 60092-353 / IEC 60331-21 / IEC 60332-3-22 Cat. A) featuring tinned copper conductors (3×70+1×35 mm²), mica fire tape + xlpe insulation and shf1 zero-halogen outer sheath (nc) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Tinned Copper Conductors (3×70+1×35 mm²) | Three 70 mm² phase cores plus one 35 mm² reduced neutral/earth core |
| 2 | Mica Fire Tape + XLPE Insulation | Phlogopite mica fire barrier (NC) + 90 °C XLPE insulation |
| 3 | LSZH Extruded Inner Sheath | Halogen-free inner bedding jacket over cabled cores |
| 4 | Tinned Copper Wire Braid Armour (86) | Braided tinned copper wire armour for mechanical & EMC protection |
| 5 | SHF1 Zero-Halogen Outer Sheath (NC) | Low-smoke zero-halogen polyolefin outer jacket (IEC 60331 & 60332-3-22) |
Built to IEC 60092-353 / IEC 60331-21 / IEC 60332-3-22 Cat. A with tinned copper conductors (3×70+1×35 mm²) and shf1 zero-halogen outer sheath (nc)
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to IEC 60092-353 / IEC 60331-21 / IEC 60332-3-22 Cat. A for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| CJ86/NC & CJ86/SC 0.6/1 KV & CHJ86/NC Construction Schedule (−40…+90 °C) | |||||||
| CJ86 3×16+1G16 mm² | 3 × 16 + 1G16 mm² (4G16) | IEC 60228 Class 2/5 Cu/SnCu | 22.4 | 920 | 3.8 | 135 | |
| CJ86 3×35+1G16 mm² | 3 × 35 + 1G16 mm² (4G35) | IEC 60228 Class 2/5 Cu/SnCu | 28.8 | 1,690 | 7.4 | 175 | |
| CJ86 3×70+1G35 mm² | 3 × 70 + 1G35 mm² (4G70) | IEC 60228 Class 2/5 Cu/SnCu | 38.2 | 3,260 | 14.8 | 230 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 16 + 1G16 mm² (4G16) | 1.15 | 0.6/1 kV (98 A) | −40…+90 °C |
| 3 × 35 + 1G16 mm² (4G35) | 0.52 | 0.6/1 kV (158 A) | −40…+90 °C |
| 3 × 70 + 1G35 mm² (4G70) | 0.27 | 0.6/1 kV (245 A) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEC 60092-353 / IEC 60331-21 / IEC 60332-3-22 Cat. A) | DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60092-353 / IEC 60331-21 / IEC 60332-3-22 Cat. A tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEC 60092-353 / IEC 60331-21 / IEC 60332-3-22 Cat. A) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (IEC 60092-353 / IEC 60331-21 / IEC 60332-3-22 Cat. A) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.