CW1128 Jelly-Filled Cellular-PE External Telecom CableBT CW1128 / BS EN 50288 · 150 V DC · -30 °C to +70 °C industrial CW1128 construction

CW1128 Jelly-Filled Cellular-PE Insulated External Copper Telecom Cable (CW1128) engineered to BT CW1128 / BS EN 50288 for 150 V DC service across -30 °C to +70 °C, featuring stranded copper conductor and pe outer sheath with minimum bending radius 10 × OD.

Approved
Outdoor & humid
Ozone, UV & moisture
Water-resistant
Order designation
CW1128 4×2×1.0
Outer Ø ≈
13.5 mm
Total weight ≈
264 kg/km
Min. bend R (fixed)
108 mm
Configuration
4×2×1.0 mm²
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
150 V DC
Per BT CW1128 / BS EN 50288
Operating temp.
−30…+70 °C
Continuous thermal rating (BT CW1128)
Min. bend radius
10 × OD
Installed / fixed routing
Conductor
copper conductor
High-conductivity copper conductor
Outer layer
PE outer sheath
Extruded PE outer sheath protective
Standard
BT CW1128
BT CW1128 / BS EN 50288

Typical values for this cable type, based on BT CW1128 / BS EN 50288 — confirmed in the datasheet and quotation for your order.

Application fit

Is CW1128 right for your machine?

CW1128 Jelly-Filled Cellular-PE Insulated External Copper Telecom Cable (CW1128) engineered to BT CW1128 / BS EN 50288 for 150 V DC service across -30 °C to +70 °C, featuring stranded copper conductor and pe outer sheath with minimum bending radius 10 × OD.

Fixed installation

Suitable

Engineered and verified for fixed service in accordance with BT CW1128 / BS EN 50288.

Switchgear & control cabinet wiring

Suitable

Suitable for switchgear, control panels and equipment terminations within 10 × OD bend radius.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Motorised monospiral reel

Not suitable

Not designed for high-speed monospiral crane reeling; select a dedicated reeling cable.

NSHTOU Reeling Cable
Typical machinesBuilding & Fire SafetyCommercial & Residential Building DistributionData Centers & Public InfrastructureFire-Safe Evacuation & Riser ShaftsIndustrial Plant Balance-of-Plant Wiring25 kV AC & 1.5/3 kV DC Railway Overhead Catenary

Construction

Layer by layer

Shown: CW1128 (BT CW1128 / BS EN 50288) with stranded copper conductor, cellular hdpe core insulation and pe outer sheath (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded copper conductorHigh-conductivity copper conductor per BT CW1128 / BS EN 50288BT CW1128 / BS EN 50288
2Cellular HDPE core insulationExtruded Cellular HDPE dielectric (individual core / group layer)BT CW1128 / BS EN 50288
3Polyester tape and petrolatum fillingPolyester tape and petrolatum filling (lapped tape)BT CW1128 / BS EN 50288
4PE outer sheathExtruded PE outer sheath protective layer (continuous layer)BT CW1128 / BS EN 50288

CW1128 — Standard Execution

Built to BT CW1128 / BS EN 50288 with stranded copper conductor and pe outer sheath

CW1128 — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per BT CW1128 / BS EN 50288

CW1128 — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on BT CW1128 / BS EN 50288. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
150 V DC (BT CW1128 / BS EN 50288)
Conductor construction
Stranded copper conductor — High-conductivity copper conductor per BT CW1128 / BS EN 50288
Primary insulation / dielectric
Cellular HDPE core insulation — Extruded Cellular HDPE dielectric (individual core / group layer)

Thermal

Continuous operating temperature
−30…+70 °C per BT CW1128 / BS EN 50288
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
PE outer sheath — Extruded PE outer sheath protective layer (continuous layer)
Minimum bending radius
10 × OD (installed / static routing)
Layer count & geometry
4 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with BT CW1128 / BS EN 50288
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
BT CW1128 / BS EN 50288
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
CW1128
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

12 standard CW1128 cable configurations

Manufactured to BT CW1128 / BS EN 50288 in single-pair, multi-pair and multi-unit constructions.

Dimensions, construction & weights
Order designationConfigurationOuter Ø ≈
mm
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
CW1128 Standard Construction Schedule (150 V DC · −30…+70 °C)
CW1128 1×2×0.51×2×0.5 mm²6.45852
CW1128 2×2×0.52×2×0.5 mm²9.211274
CW1128 4×2×0.54×2×0.5 mm²11.417692
CW1128 8×2×0.58×2×0.5 mm²14.8295118
CW1128 12×2×0.512×2×0.5 mm²17.6420141
CW1128 1×2×1.01×2×1.0 mm²7.68661
CW1128 2×2×1.02×2×1.0 mm²11.016888
CW1128 4×2×1.04×2×1.0 mm²13.5264108
CW1128 8×2×1.08×2×1.0 mm²17.9465143
CW1128 1×2×1.51×2×1.5 mm²8.511468
CW1128 4×2×1.54×2×1.5 mm²15.2348122
CW1128 12×2×1.512×2×1.5 mm²23.4860187
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Additional pair/triad/quad counts (up to 48 pairs) and blue Ex-i intrinsically safe outer sheaths available per BT CW1128 / BS EN 50288.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (BT CW1128 / BS EN 50288)DC resistance at 20 °C and geometry within BT CW1128 / BS EN 50288 class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (BT CW1128 / BS EN 50288)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (BT CW1128 / BS EN 50288)Full compliance with BT CW1128 / BS EN 50288 across −30…+70 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

BT CW1128 CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX CW1128 <size> BT CW1128 150 V DC CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define CW1128 (CW1128 Jelly-Filled Cellular-PE Insulated External Copper Telecom Cable)?
CW1128 (CW1128 Jelly-Filled Cellular-PE Insulated External Copper Telecom Cable) is manufactured in accordance with BT CW1128 / BS EN 50288 for 150 V DC service over -30 °C to +70 °C. Its 4-layer construction comprises stranded copper conductor, cellular hdpe core insulation, polyester tape and petrolatum filling, pe outer sheath.
What is the minimum bending radius and installation temperature for CW1128?
The minimum installed bending radius for CW1128 is 10 × OD across its continuous operating temperature range of -30 °C to +70 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of CW1128 arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded copper conductor (High-conductivity copper conductor per BT CW1128 / BS EN 50288); (02) Cellular HDPE core insulation (Extruded Cellular HDPE dielectric (individual core / group layer)); (03) Polyester tape and petrolatum filling (Polyester tape and petrolatum filling (lapped tape)); (04) PE outer sheath (Extruded PE outer sheath protective layer (continuous layer)).
What factory test certificates are supplied with CW1128?
Every production drum or spool of CW1128 undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per BT CW1128 / BS EN 50288, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for CW1128

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

CW1128 Jelly-Filled Cellular-PE External Telecom Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote