Contact
ANSI P3 750 JCAANSI/SCTE 74 / Telcordia90 V AC Power-Passing−40…+85 °C

P3 750 JCA 75 Ohm Hardline Aluminum CATV Trunk Coaxial CableANSI/SCTE 74 / Telcordia · 90 V AC Power-Passing · -40 °C to +85 °C industrial P3 750 JCA

P3 750 JCA 75 Ohm Hardline Solid-Aluminum-Sheathed CATV Broadband Trunk Coaxial Cable (P3 750 JCA) engineered to ANSI/SCTE 74 / Telcordia for 90 V AC Power-Passing service across -40 °C to +85 °C, featuring stranded copper-clad aluminum (cca) conductor and

Approved
Low-EMC design
EMC screen
Outdoor & humid
Order designation
P3 750 JCA 4×2×1.0
Outer Ø ≈
13.5 mm
Total weight ≈
264 kg/km
Min. bend R (fixed)
108 mm
Configuration
4×2×1.0 mm²
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
90 V AC Power-Pa
Per ANSI/SCTE 74 / Telcordia
Operating temp.
−40…+85 °C
Continuous thermal rating (ANSI)
Min. bend radius
10 × OD
Installed / fixed routing
Conductor
copper-clad
High-conductivity copper-clad
Outer layer
Black PE outer
Extruded Black PE outer jacket
Standard
ANSI
ANSI/SCTE 74 / Telcordia

Typical values for this cable type, based on ANSI/SCTE 74 / Telcordia — confirmed in the datasheet and quotation for your order.

Application fit

Is P3 750 JCA right for your machine?

P3 750 JCA 75 Ohm Hardline Solid-Aluminum-Sheathed CATV Broadband Trunk Coaxial Cable (P3 750 JCA) engineered to ANSI/SCTE 74 / Telcordia for 90 V AC Power-Passing service across -40 °C to +85 °C, featuring stranded copper-clad aluminum (cca) conductor and

Fixed installation

Suitable

Engineered and verified for fixed service in accordance with ANSI/SCTE 74 / Telcordia.

Switchgear & control cabinet wiring

Suitable

Suitable for switchgear, control panels and equipment terminations within 10 × OD bend radius.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Motorised monospiral reel

Not suitable

Not designed for high-speed monospiral crane reeling; select a dedicated reeling cable.

NSHTOU Reeling Cable
Typical machinesBuilding & Fire SafetyCommercial & Residential Building DistributionData Centers & Public InfrastructureFire-Safe Evacuation & Riser ShaftsIndustrial Plant Balance-of-Plant Wiring25 kV AC & 1.5/3 kV DC Railway Overhead Catenary

Construction

Layer by layer

Shown: P3 750 JCA (ANSI/SCTE 74 / Telcordia) with stranded copper-clad aluminum (cca) conductor, foam pe dielectric and black pe outer jacket (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded copper-clad aluminum (CCA) conductorHigh-conductivity copper-clad aluminum (CCA) conductor per ANSI/SCTE 74 / TelcordiaANSI/SCTE 74 / Telcordia
2Foam PE dielectricExtruded Foam PE dielectric dielectric (continuous layer)ANSI/SCTE 74 / Telcordia
3Aluminium outer conductorAluminium outer conductor metallic electromagnetic screen (continuous layer)ANSI/SCTE 74 / Telcordia
4Black PE outer jacketExtruded Black PE outer jacket protective layer (continuous layer)ANSI/SCTE 74 / Telcordia

P3 750 JCA — Standard Execution

Built to ANSI/SCTE 74 / Telcordia with stranded copper-clad aluminum (cca) conductor and black pe outer jacket

P3 750 JCA — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per ANSI/SCTE 74 / Telcordia

P3 750 JCA — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on ANSI/SCTE 74 / Telcordia. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
90 V AC Power-Passing (ANSI/SCTE 74 / Telcordia)
Conductor construction
Stranded copper-clad aluminum (CCA) conductor — High-conductivity copper-clad aluminum (CCA) conductor per ANSI/SCTE 74 / Telcordia
Primary insulation / dielectric
Foam PE dielectric — Extruded Foam PE dielectric dielectric (continuous layer)

Thermal

Continuous operating temperature
−40…+85 °C per ANSI/SCTE 74 / Telcordia
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
Black PE outer jacket — Extruded Black PE outer jacket protective layer (continuous layer)
Minimum bending radius
10 × OD (installed / static routing)
Layer count & geometry
4 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with ANSI/SCTE 74 / Telcordia
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
ANSI/SCTE 74 / Telcordia
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
P3 750 JCA
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

12 standard P3 750 JCA cable configurations

Manufactured to ANSI/SCTE 74 / Telcordia in single-pair, multi-pair and multi-unit constructions.

Dimensions, construction & weights
Order designationConfigurationOuter Ø ≈
mm
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
P3 750 JCA Standard Construction Schedule (90 V AC Power-Passing · −40…+85 °C)
P3 750 JCA 1×2×0.51×2×0.5 mm²6.45852
P3 750 JCA 2×2×0.52×2×0.5 mm²9.211274
P3 750 JCA 4×2×0.54×2×0.5 mm²11.417692
P3 750 JCA 8×2×0.58×2×0.5 mm²14.8295118
P3 750 JCA 12×2×0.512×2×0.5 mm²17.6420141
P3 750 JCA 1×2×1.01×2×1.0 mm²7.68661
P3 750 JCA 2×2×1.02×2×1.0 mm²11.016888
P3 750 JCA 4×2×1.04×2×1.0 mm²13.5264108
P3 750 JCA 8×2×1.08×2×1.0 mm²17.9465143
P3 750 JCA 1×2×1.51×2×1.5 mm²8.511468
P3 750 JCA 4×2×1.54×2×1.5 mm²15.2348122
P3 750 JCA 12×2×1.512×2×1.5 mm²23.4860187
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Additional pair/triad/quad counts (up to 48 pairs) and blue Ex-i intrinsically safe outer sheaths available per ANSI/SCTE 74 / Telcordia.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (ANSI/SCTE 74 / Telcordia)DC resistance at 20 °C and geometry within ANSI/SCTE 74 / Telcordia class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (ANSI/SCTE 74 / Telcordia)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (ANSI/SCTE 74 / Telcordia)Full compliance with ANSI/SCTE 74 / Telcordia across −40…+85 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

ANSI CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX P3 750 JCA <size> ANSI 90 V AC Power-Passing CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define P3 750 JCA (P3 750 JCA 75 Ohm Hardline Solid-Aluminum-Sheathed CATV Broadband Trunk Coaxial Cable)?
P3 750 JCA (P3 750 JCA 75 Ohm Hardline Solid-Aluminum-Sheathed CATV Broadband Trunk Coaxial Cable) is manufactured in accordance with ANSI/SCTE 74 / Telcordia for 90 V AC Power-Passing service over -40 °C to +85 °C. Its 4-layer construction comprises stranded copper-clad aluminum (cca) conductor, foam pe dielectric, aluminium outer conductor, black pe outer jacket.
What is the minimum bending radius and installation temperature for P3 750 JCA?
The minimum installed bending radius for P3 750 JCA is 10 × OD across its continuous operating temperature range of -40 °C to +85 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of P3 750 JCA arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded copper-clad aluminum (CCA) conductor (High-conductivity copper-clad aluminum (CCA) conductor per ANSI/SCTE 74 / Telcordia); (02) Foam PE dielectric (Extruded Foam PE dielectric dielectric (continuous layer)); (03) Aluminium outer conductor (Aluminium outer conductor metallic electromagnetic screen (continuous layer)); (04) Black PE outer jacket (Extruded Black PE outer jacket protective layer (continuous layer)).
What factory test certificates are supplied with P3 750 JCA?
Every production drum or spool of P3 750 JCA undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per ANSI/SCTE 74 / Telcordia, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for P3 750 JCA

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

P3 750 JCA 75 Ohm Hardline Aluminum CATV Trunk Coaxial Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp