Cat 8.2 S/FTP 4×2×22 AWG 2000 MHz 40GBASE-T LSZH Data Center CableISO/IEC 11801-1 Class II / IEC 61156-9 · 300 V (PoE++ Type 4) · -20 °C to +75 °C industrial

Category 8.2 S/FTP 4×2×22 AWG 2000 MHz 40GBASE-T LSZH Data Center Cable (CAT8.2 S/FTP 22 AWG) engineered to ISO/IEC 11801-1 Class II / IEC 61156-9 for 300 V (PoE++ Type 4) service across -20 °C to +75 °C, featuring stranded copper conductor and lszh outer

Approved
Low-EMC design
EMC screen
Flame-retardant
Order designation
CAT8.2 S/FTP 22 AWG 4×2×1.0
Outer Ø ≈
13.5 mm
Total weight ≈
264 kg/km
Min. bend R (fixed)
108 mm
Configuration
4×2×1.0 mm²
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300 V (PoE++
Per ISO/IEC 11801-1 Class II / IEC
Operating temp.
−20…+75 °C
Continuous thermal rating (ISO)
Min. bend radius
8 × OD
Installed / fixed routing
Conductor
copper conductor
High-conductivity copper conductor
Outer layer
LSZH outer
Extruded LSZH outer sheath RAL 1021
Standard
ISO
ISO/IEC 11801-1 Class II / IEC 61156-9

Typical values for this cable type, based on ISO/IEC 11801-1 Class II / IEC 61156-9 — confirmed in the datasheet and quotation for your order.

Application fit

Is CAT8.2 S/FTP 22 AWG right for your machine?

Category 8.2 S/FTP 4×2×22 AWG 2000 MHz 40GBASE-T LSZH Data Center Cable (CAT8.2 S/FTP 22 AWG) engineered to ISO/IEC 11801-1 Class II / IEC 61156-9 for 300 V (PoE++ Type 4) service across -20 °C to +75 °C, featuring stranded copper conductor and lszh outer

Fixed installation

Suitable

Engineered and verified for fixed service in accordance with ISO/IEC 11801-1 Class II / IEC 61156-9.

Switchgear & control cabinet wiring

Suitable

Engineered and verified for cabinet chassis service in accordance with ISO/IEC 11801-1 Class II / IEC 61156-9.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Motorised monospiral reel

Not suitable

Not designed for high-speed monospiral crane reeling; select a dedicated reeling cable.

NSHTOU Reeling Cable
Typical machinesBuilding & Fire SafetyCommercial & Residential Building DistributionData Centers & Public InfrastructureFire-Safe Evacuation & Riser ShaftsIndustrial Plant Balance-of-Plant WiringAutomated Assembly & Packaging Lines

Construction

Layer by layer

Shown: CAT8.2 S/FTP 22 AWG (ISO/IEC 11801-1 Class II / IEC 61156-9) with stranded copper conductor, al-plastic pair foil and lszh outer sheath ral 1021 (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded copper conductorHigh-conductivity copper conductor per ISO/IEC 11801-1 Class II / IEC 61156-9ISO/IEC 11801-1 Class II / IEC 61156-9
2Al-plastic pair foilAl-plastic pair foil metallic electromagnetic screen (individual core / group layer)ISO/IEC 11801-1 Class II / IEC 61156-9
3Foam-skin PE core insulationExtruded Foam-skin PE dielectric (individual core / group layer)ISO/IEC 11801-1 Class II / IEC 61156-9
4Overall tinned copper braidOverall tinned copper braid high-coverage braided layer (woven structure)ISO/IEC 11801-1 Class II / IEC 61156-9
5LSZH outer sheath RAL 1021Extruded LSZH outer sheath RAL 1021 protective layer (continuous layer)ISO/IEC 11801-1 Class II / IEC 61156-9

CAT8.2 S/FTP 22 AWG — Standard Execution

Built to ISO/IEC 11801-1 Class II / IEC 61156-9 with stranded copper conductor and lszh outer sheath ral 1021

CAT8.2 S/FTP 22 AWG — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per ISO/IEC 11801-1 Class II / IEC 61156-9

CAT8.2 S/FTP 22 AWG — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on ISO/IEC 11801-1 Class II / IEC 61156-9. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
300 V (PoE++ Type 4) (ISO/IEC 11801-1 Class II / IEC 61156-9)
Conductor construction
Stranded copper conductor — High-conductivity copper conductor per ISO/IEC 11801-1 Class II / IEC 61156-9
Primary insulation / dielectric
Al-plastic pair foil — Al-plastic pair foil metallic electromagnetic screen (individual core / group layer)

Thermal

Continuous operating temperature
−20…+75 °C per ISO/IEC 11801-1 Class II / IEC 61156-9
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
LSZH outer sheath RAL 1021 — Extruded LSZH outer sheath RAL 1021 protective layer (continuous layer)
Minimum bending radius
8 × OD (installed / static routing)
Layer count & geometry
5 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with ISO/IEC 11801-1 Class II / IEC 61156-9
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
ISO/IEC 11801-1 Class II / IEC 61156-9
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
CAT8.2 S/FTP 22 AWG
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

12 standard CAT8.2 S/FTP 22 AWG cable configurations

Manufactured to ISO/IEC 11801-1 Class II / IEC 61156-9 in single-pair, multi-pair and multi-unit constructions.

Dimensions, construction & weights
Order designationConfigurationOuter Ø ≈
mm
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
CAT8.2 S/FTP 22 AWG Standard Construction Schedule (300 V (PoE++ Type 4) · −20…+75 °C)
CAT8.2 S/FTP 22 AWG 1×2×0.51×2×0.5 mm²6.45852
CAT8.2 S/FTP 22 AWG 2×2×0.52×2×0.5 mm²9.211274
CAT8.2 S/FTP 22 AWG 4×2×0.54×2×0.5 mm²11.417692
CAT8.2 S/FTP 22 AWG 8×2×0.58×2×0.5 mm²14.8295118
CAT8.2 S/FTP 22 AWG 12×2×0.512×2×0.5 mm²17.6420141
CAT8.2 S/FTP 22 AWG 1×2×1.01×2×1.0 mm²7.68661
CAT8.2 S/FTP 22 AWG 2×2×1.02×2×1.0 mm²11.016888
CAT8.2 S/FTP 22 AWG 4×2×1.04×2×1.0 mm²13.5264108
CAT8.2 S/FTP 22 AWG 8×2×1.08×2×1.0 mm²17.9465143
CAT8.2 S/FTP 22 AWG 1×2×1.51×2×1.5 mm²8.511468
CAT8.2 S/FTP 22 AWG 4×2×1.54×2×1.5 mm²15.2348122
CAT8.2 S/FTP 22 AWG 12×2×1.512×2×1.5 mm²23.4860187
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Additional pair/triad/quad counts (up to 48 pairs) and blue Ex-i intrinsically safe outer sheaths available per ISO/IEC 11801-1 Class II / IEC 61156-9.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (ISO/IEC 11801-1 Class II / IEC 61156-9)DC resistance at 20 °C and geometry within ISO/IEC 11801-1 Class II / IEC 61156-9 class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (ISO/IEC 11801-1 Class II / IEC 61156-9)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (ISO/IEC 11801-1 Class II / IEC 61156-9)Full compliance with ISO/IEC 11801-1 Class II / IEC 61156-9 across −20…+75 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

ISO CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX CAT8.2 S/FTP 22 AWG <size> ISO 300 V (PoE++ Type 4) CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define CAT8.2 S/FTP 22 AWG (Category 8.2 S/FTP 4×2×22 AWG 2000 MHz 40GBASE-T LSZH Data Center Cable)?
CAT8.2 S/FTP 22 AWG (Category 8.2 S/FTP 4×2×22 AWG 2000 MHz 40GBASE-T LSZH Data Center Cable) is manufactured in accordance with ISO/IEC 11801-1 Class II / IEC 61156-9 for 300 V (PoE++ Type 4) service over -20 °C to +75 °C. Its 5-layer construction comprises stranded copper conductor, al-plastic pair foil, foam-skin pe core insulation, overall tinned copper braid, lszh outer sheath ral 1021.
What is the minimum bending radius and installation temperature for CAT8.2 S/FTP 22 AWG?
The minimum installed bending radius for CAT8.2 S/FTP 22 AWG is 8 × OD across its continuous operating temperature range of -20 °C to +75 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of CAT8.2 S/FTP 22 AWG arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded copper conductor (High-conductivity copper conductor per ISO/IEC 11801-1 Class II / IEC 61156-9); (02) Al-plastic pair foil (Al-plastic pair foil metallic electromagnetic screen (individual core / group layer)); (03) Foam-skin PE core insulation (Extruded Foam-skin PE dielectric (individual core / group layer)); (04) Overall tinned copper braid (Overall tinned copper braid high-coverage braided layer (woven structure)); (05) LSZH outer sheath RAL 1021 (Extruded LSZH outer sheath RAL 1021 protective layer (continuous layer)).
What factory test certificates are supplied with CAT8.2 S/FTP 22 AWG?
Every production drum or spool of CAT8.2 S/FTP 22 AWG undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per ISO/IEC 11801-1 Class II / IEC 61156-9, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for CAT8.2 S/FTP 22 AWG

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

Cat 8.2 S/FTP 4×2×22 AWG 2000 MHz 40GBASE-T LSZH Data Center Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote