Contact

UL AWM 1422 / 1516 ETFE Thin-Wall Wire-Wrap WireSolid silver-plated copper ultra-thin ETFE wire-wrap & PCB jumper wire

UL 1422 / 1516 ETFE Wire-Wrap uses solid silver-plated copper with ultra-thin blue ETFE fluoropolymer insulation (4–6 mil) for backplane wire-wrapping, PCB rework jumpers, and miniature medical/test probes.

Flame-retardant
Oil-resistant
Approved
Order designation
UL 1422/1516 ETFE Wire 1×28 AWG
Outer Ø
0.6 mm
Max. R20
213.00 Ω/km
Weight
9 kg/km
Min. bend R
3.0 mm
All sizes (4)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300 V
Test voltage 1.5 kV AC
Temp. (fixed)
-65°C…+105°C
Flexing: -40 °C to +105 °C
Insulation
ETFE
Blue ultra-thin extruded ETFE
Min. bend radius
5 × OD
Fixed & equipment routing
Conductor
Silver-Plated Cu
Per UL AWM Style 1422
Size range
1×30–1×24
4 standard configurations

Typical values for this cable type, based on UL AWM Style 1422 · UL AWM Style 1516 · ASTM B298 Silver Cu — confirmed in the datasheet and quotation for your order.

Application fit

Is UL 1422/1516 ETFE Wire right for your machine?

UL 1422 / 1516 ETFE Wire-Wrap uses solid silver-plated copper with ultra-thin blue ETFE fluoropolymer insulation (4–6 mil) for backplane wire-wrapping, PCB rework jumpers, and miniature medical/test probes.

Switchgear & control cabinet wiring

Suitable

Compact 300 V ETFE profile simplifies high-density routing inside control panels, avionics racks, and equipment chassis.

Furnace, kiln & high-temp zone

Suitable

Thermal-rated 300 V ETFE insulation maintains dielectric safety across continuous high-temperature zones up to +105 °C.

Control cabinet & internal panel wiring

Suitable

Compact flame-retardant 300 V ETFE geometry routes neatly through dense switchgear ducts, control cabinets, and DIN-rail terminals.

Precision test bench & clean equipment

Suitable

Clean, low-outgassing 300 V ETFE construction fits laboratory instruments, precision test benches, and controlled indoor enclosures.

Energy chain / drag chain

Not suitable

300 V ETFE construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Immersion & wet locations

Not suitable

300 V ETFE outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesIndustrial ovens, kilns & thermal processingAerospace avionics, defence & instrumentationSteelworks, glassworks & foundry equipmentSwitchgear cabinets, motors & heating appliances

Construction

Layer by layer

Representative construction of UL 1422/1516 ETFE Wire: ASTM B298 solid silver-plated annealed copper, Blue ultra-thin extruded ETFE fluoropolymer insulation, and Blue ultra-thin extruded ETFE fluoropolymer outer insulation.

12
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorASTM B298 solid silver-plated annealed copperASTM B298 Silver Cu
2Extruded insulationBlue ultra-thin extruded ETFE fluoropolymer insulationUL AWM Style 1422

UL 1422/1516 ETFE Wire Single-Core

Single-conductor high-temperature wire with extruded Blue ultra-thin extruded ETFE fluoropolymer insulation.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on UL AWM Style 1422 · UL AWM Style 1516 · ASTM B298 Silver Cu. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
300 V
Test voltage
1.5 kV AC
Conductor
ASTM B298 solid silver-plated annealed copper
Insulation
Blue ultra-thin extruded ETFE
Impedance / insulation
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-65 °C to +105 °C
Temp. range (flexing)
-40 °C to +105 °C
Peak / short-circuit
+160 °C (5 s)
Min. bending radius
5 × OD (fixed)

Resistance

Flame / fire rating
UL VW-1 Flame
Thermal / chemical
Ultra-Thin 4–6 mil ETFE
Mechanical / special
High Cut-Through Strength
Outer finish
Blue ultra-thin extruded ETFE

Sizes

Single-Core High-Temp Hook-Up Wire (AWG)
Conductor
AWG
Outer Ø ≈
mm
Max. R20
Ω/km
Metal index
kg/km
Weight ≈
kg/km
Min. bend R
5×D mm
1×30 AWG0.5340.00192.5
1×28 AWG0.6213.00193.0
1×26 AWG0.7134.00193.5
1×24 AWG0.884.202114.0
  • Conductor DC resistance R20 at 20 °C per ASTM B298 Silver Cu.
  • Minimum bending radius calculated at 5 × nominal outer diameter (OD). Custom core counts and lengths available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
High-voltage dielectric spark / withstand test1.5 kV AC without breakdownEvery manufactured drum
Conductor DC resistance checkPer ASTM B298 Silver Cu at 20 °CEvery reel / drum length
Sample tests
Dimensional, wall thickness & thermal agingRated -65 °C to +105 °C continuousPer production lot
Flame, chemical & mechanical qualificationUL VW-1 Flame · Ultra-Thin 4–6 mil ETFEType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL AWM Style 1422UL AWM Style 1516ASTM B298 Silver CuEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

UL 1422/1516 ETFE Wire 300 V TEBAOFLEX.COM [UL AWM Style 1422] [Size] [Metre mark]
Delivery form
Spools, coils or wooden export reels
Standard lengths
305 m (1,000 ft) · 500 m · 1,000 m
MOQ
100 m (stock sizes) · 500 m (production)
Lead time
2–3 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-22
Updated
2026-11-22

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes UL 1422/1516 ETFE Wire suited for 300 V and -65 °C to +105 °C operation?
UL 1422/1516 ETFE Wire combines ASTM B298 solid silver-plated annealed copper with Blue ultra-thin extruded ETFE fluoropolymer insulation and Blue ultra-thin extruded ETFE fluoropolymer outer insulation. Tough thin-wall ETFE resists sharp wire-wrap post corners while enabling high-density 24–30 AWG routing.
What is the minimum bending radius of UL 1422/1516 ETFE Wire during installation?
Maintain a minimum bending radius of 5 × OD across -40 °C to +105 °C flexing temperatures to protect conductor stranding and dielectric integrity.
Can UL 1422/1516 ETFE Wire be supplied in custom lengths, colours, or core configurations?
Yes. TEBAOFLEX supplies UL 1422/1516 ETFE Wire cut-to-length or on export reels with optional colour coding, jacket printing, and factory pre-termination.
What standards and quality certificates accompany UL 1422/1516 ETFE Wire?
UL 1422/1516 ETFE Wire conforms to UL AWM Style 1422, UL AWM Style 1516, ASTM B298 Silver Cu (UL VW-1 Flame) and ships with an EN 10204 3.1 routine factory test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for UL 1422/1516 ETFE Wire

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

UL AWM 1422 / 1516 ETFE Thin-Wall Wire-Wrap Wire

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote