Contact

UL AWM 1726 300 V 250 °C PFA High-Temp Hook-Up WireUL 758 Style 1726 300 V 250 °C thin-wall PFA fluoropolymer lead wire

UL 1726 250 °C 300 V PFA combines nickel-plated copper conductors with smooth 13-mil yellow extruded PFA fluoropolymer insulation for 250 °C heating appliances, thermal fuses, and lab analyzers.

Flame-retardant
Oil-resistant
Approved
Order designation
UL 1726 300V PFA 1×22 AWG
Outer Ø
1.3 mm
Max. R20
64.75 Ω/km
Weight
12 kg/km
Min. bend R
7.8 mm
All sizes (8)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300 V
Test voltage 2 kV AC
Temp. (fixed)
-100°C…+250°C
Flexing: -65 °C to +250 °C
Insulation
PFA
Yellow 13-mil extruded PFA
Min. bend radius
6 × OD
Fixed & equipment routing
Conductor
Nickel-Plated Cu
Per UL AWM Style 1726
Size range
1×28–1×14
8 standard configurations

Typical values for this cable type, based on UL AWM Style 1726 · UL 758 · CSA AWM I A/B — confirmed in the datasheet and quotation for your order.

Application fit

Is UL 1726 300V PFA right for your machine?

UL 1726 250 °C 300 V PFA combines nickel-plated copper conductors with smooth 13-mil yellow extruded PFA fluoropolymer insulation for 250 °C heating appliances, thermal fuses, and lab analyzers.

Switchgear & control cabinet wiring

Suitable

Compact 300 V PFA profile simplifies high-density routing inside control panels, avionics racks, and equipment chassis.

Furnace, kiln & high-temp zone

Suitable

Thermal-rated 300 V PFA insulation maintains dielectric safety across continuous high-temperature zones up to +250 °C.

High-temperature boiler & thermal plant

Suitable

Thermal-aged 300 V PFA insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.

Precision test bench & clean equipment

Suitable

Clean, low-outgassing 300 V PFA construction fits laboratory instruments, precision test benches, and controlled indoor enclosures.

Energy chain / drag chain

Not suitable

300 V PFA construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Immersion & wet locations

Not suitable

300 V PFA outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesIndustrial ovens, kilns & thermal processingAerospace avionics, defence & instrumentationSteelworks, glassworks & foundry equipmentSwitchgear cabinets, motors & heating appliances

Construction

Layer by layer

Representative construction of UL 1726 300V PFA: ASTM B355 Class K stranded nickel-plated annealed copper, Yellow 13-mil extruded PFA fluoropolymer insulation (250 °C), and Yellow 13-mil extruded PFA fluoropolymer outer insulation.

12
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorASTM B355 Class K stranded nickel-plated annealed copperASTM B355 Nickel Cu
2Extruded insulationYellow 13-mil extruded PFA fluoropolymer insulation (250 °C)UL AWM Style 1726

UL 1726 300V PFA Single-Core

Single-conductor high-temperature wire with extruded Yellow 13-mil extruded PFA fluoropolymer insulation (250 °C).

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on UL AWM Style 1726 · UL 758 · CSA AWM I A/B. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
300 V
Test voltage
2 kV AC
Conductor
Nickel-Plated Cu
Insulation
Yellow 13-mil extruded PFA fluoropolymer
Impedance / insulation
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-100 °C to +250 °C
Temp. range (flexing)
-65 °C to +250 °C
Peak / short-circuit
+300 °C (short-term)
Min. bending radius
6 × OD (fixed)

Resistance

Flame / fire rating
UL VW-1 / FT1 Flame
Thermal / chemical
250 °C Continuous PFA
Mechanical / special
Acid & Steam Resistant
Outer finish
Yellow 13-mil extruded PFA fluoropolymer

Sizes

Single-Core High-Temp Hook-Up Wire (AWG)
Conductor
AWG
Outer Ø ≈
mm
Max. R20
Ω/km
Metal index
kg/km
Weight ≈
kg/km
Min. bend R
6×D mm
1×28 AWG0.9259.42195.4
1×26 AWG1.0163.50196.0
1×24 AWG1.1102.682116.6
1×22 AWG1.364.753127.8
1×20 AWG1.540.005149.0
1×18 AWG1.725.2971710.2
1×16 AWG2.016.02122312.0
1×14 AWG2.49.89193514.0
  • Conductor DC resistance R20 at 20 °C per ASTM B355 Nickel Cu.
  • Minimum bending radius calculated at 6 × nominal outer diameter (OD). Custom core counts and lengths available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
High-voltage dielectric spark / withstand test2 kV AC without breakdownEvery manufactured drum
Conductor DC resistance checkPer ASTM B355 Nickel Cu at 20 °CEvery reel / drum length
Sample tests
Dimensional, wall thickness & thermal agingRated -100 °C to +250 °C continuousPer production lot
Flame, chemical & mechanical qualificationUL VW-1 / FT1 Flame · 250 °C Continuous PFAType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL AWM Style 1726UL 758CSA AWM I A/BEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

UL 1726 300V PFA 300 V TEBAOFLEX.COM [UL AWM Style 1726] [Size] [Metre mark]
Delivery form
Spools, coils or wooden export reels
Standard lengths
305 m (1,000 ft) · 500 m · 1,000 m
MOQ
100 m (stock sizes) · 500 m (production)
Lead time
2–3 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-22
Updated
2026-11-22

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes UL 1726 300V PFA suited for 300 V and -100 °C to +250 °C operation?
UL 1726 300V PFA combines ASTM B355 Class K stranded nickel-plated annealed copper with Yellow 13-mil extruded PFA fluoropolymer insulation (250 °C) and Yellow 13-mil extruded PFA fluoropolymer outer insulation. Smooth melt-extruded PFA delivers pinhole-free 250 °C insulation for long continuous runs.
What is the minimum bending radius of UL 1726 300V PFA during installation?
Maintain a minimum bending radius of 6 × OD across -65 °C to +250 °C flexing temperatures to protect conductor stranding and dielectric integrity.
Can UL 1726 300V PFA be supplied in custom lengths, colours, or core configurations?
Yes. TEBAOFLEX supplies UL 1726 300V PFA cut-to-length or on export reels with optional colour coding, jacket printing, and factory pre-termination.
What standards and quality certificates accompany UL 1726 300V PFA?
UL 1726 300V PFA conforms to UL AWM Style 1726, UL 758, CSA AWM I A/B (UL VW-1 / FT1 Flame) and ships with an EN 10204 3.1 routine factory test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for UL 1726 300V PFA

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

UL AWM 1726 300 V 250 °C PFA High-Temp Hook-Up Wire

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote