Contact

1-PFA-322 550 °F (288 °C) PFA Armored Wireline Cable5/16" ultra-high-temp 550 °F PFA-insulated armored monocore wireline

1-PFA-322 550°F Wireline unites a bare/alloy copper monocore and heavy-wall PFA fluoropolymer insulation with counter-helical alloy-steel armor rated up to 550 °F (288 °C) for HPHT geothermal and deep oilfield logging.

Flame-retardant
Oil-resistant
Approved
Order designation
1-PFA-322 550°F Wireline 1×16 AWG Monocore
Outer Ø
8.2 mm
Max. R20
14.70 Ω/km
Weight
275 kg/km
Min. bend R
205 mm
All sizes (4)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
1000 V
Test voltage 3.5 kV AC
Temp. (fixed)
-40°C…+288°C
Flexing: -30 °C to +288 °C
Reinforcement
GIPS Armor
Double counter-helical high-strength
Min. bend radius
25 × OD
Fixed & equipment routing
Conductor
Bare Cu · Cl.K
Per API RP 9A
Size range
1×20–1×14
4 standard configurations

Typical values for this cable type, based on API RP 9A · ICEA S-73-532 · IEEE 1580 (ref.) — confirmed in the datasheet and quotation for your order.

Application fit

Is 1-PFA-322 550°F Wireline right for your machine?

1-PFA-322 550°F Wireline unites a bare/alloy copper monocore and heavy-wall PFA fluoropolymer insulation with counter-helical alloy-steel armor rated up to 550 °F (288 °C) for HPHT geothermal and deep oilfield logging.

Drilling jumbo & rotary mast feed

Suitable

Counter-helical GIPS steel armor and 1000 V PFA core endure deep oilfield, perforating, and HPHT well-logging tension.

Free-hanging vertical run

Suitable

Self-supporting 1000 V PFA geometry handles suspended vertical runs with controlled elongation and loop stability.

Offshore mud pump & top drive

Suitable

Heavy-duty 1000 V PFA construction resists drilling muds, oil, and vibration on offshore top drives and mud-pump skids.

High-temperature boiler & thermal plant

Suitable

Thermal-aged 1000 V PFA insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.

Energy chain / drag chain

Not suitable

1000 V PFA construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Trailing & towing

Not suitable

1000 V PFA build is not engineered to be dragged across rough quarry or site ground; specify a rubber trailing cable.

Use NSHTOEU Heavy-Duty Cable
Typical machinesOil & Gas CableOnshore & offshore oilfield well loggingHPHT geothermal & deep cased-hole wellsPerforating, slickline & production telemetrySour-gas H2S/CO2 downhole intervention

Construction

Layer by layer

Representative construction of 1-PFA-322 550°F Wireline: ASTM B172 Class K flexible bare annealed copper, Heavy-wall high-temperature PFA fluoropolymer dielectric, and Counter-helical double GIPS/alloy steel outer armor (PFA fluoro core).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorASTM B172 Class K flexible bare annealed copperASTM B172 Class K
2Fluoropolymer dielectricHeavy-wall high-temperature PFA fluoropolymer dielectricAPI RP 9A
3Fluoropolymer bedding jacketExtruded high-temperature fluoropolymer (PFA/FEP) inner beddingAPI RP 9A
4Double GIPS steel wire armorDouble counter-helical high-strength steel/alloy wire armorAPI RP 9A

1-PFA-322 550°F Wireline Armored Monocore

Single central logging conductor in high-temperature fluoropolymer dielectric protected by counter-helical 12/18 GIPS armor.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on API RP 9A · ICEA S-73-532 · IEEE 1580 (ref.). Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
1000 V
Test voltage
3.5 kV AC
Conductor
Bare Cu · Cl.K
Insulation
Heavy-wall high-temperature PFA
Impedance / insulation
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-40 °C to +288 °C
Temp. range (flexing)
-30 °C to +288 °C
Peak / short-circuit
+300 °C (short-term)
Min. bending radius
25 × OD (fixed)

Resistance

Flame / fire rating
288 °C / 550 °F HPHT
Thermal / chemical
Double Alloy Armor
Mechanical / special
Geothermal & Deep Well
Outer finish
Counter-helical double GIPS/alloy steel

Sizes

Monocore Armored Logging Wireline (AWG)
Monocore
AWG
Outer Ø ≈
mm
Max. R20
Ω/km
Metal index
kg/km
Weight ≈
kg/km
Min. bend R
25×D mm
1×20 AWG Monocore6.836.706165170
1×18 AWG Monocore7.423.209215185
1×16 AWG Monocore8.214.7014275205
1×14 AWG Monocore9.19.0722345228
  • Conductor DC resistance R20 at 20 °C per ASTM B172 Class K.
  • Minimum bending radius calculated at 25 × nominal outer diameter (OD). Custom core counts and lengths available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
High-voltage dielectric spark / withstand test3.5 kV AC without breakdownEvery manufactured drum
Conductor DC resistance checkPer ASTM B172 Class K at 20 °CEvery reel / drum length
Sample tests
Dimensional, wall thickness & thermal agingRated -40 °C to +288 °C continuousPer production lot
Flame, chemical & mechanical qualification288 °C / 550 °F HPHT · Double Alloy ArmorType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

API RP 9AICEA S-73-532IEEE 1580 (ref.)EN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

1-PFA-322 550°F Wireline 1000 V TEBAOFLEX.COM [API RP 9A] [Size] [Metre mark]
Delivery form
Cut-to-length or wooden export drums
Standard lengths
305 m (1,000 ft) · 500 m · 1,000 m
MOQ
100 m (stock sizes) · 500 m (production)
Lead time
2–3 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-22
Updated
2026-11-22

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes 1-PFA-322 550°F Wireline suited for 1000 V and -40 °C to +288 °C operation?
1-PFA-322 550°F Wireline combines ASTM B172 Class K flexible bare annealed copper with Heavy-wall high-temperature PFA fluoropolymer dielectric and Counter-helical double GIPS/alloy steel outer armor (PFA fluoro core). Engineered for HPHT oil wells and 550 °F geothermal reservoirs where standard FEP logging cables soften.
What is the minimum bending radius of 1-PFA-322 550°F Wireline during installation?
Maintain a minimum bending radius of 25 × OD across -30 °C to +288 °C flexing temperatures to protect conductor stranding and dielectric integrity.
Can 1-PFA-322 550°F Wireline be supplied in custom lengths, colours, or core configurations?
Yes. TEBAOFLEX supplies 1-PFA-322 550°F Wireline cut-to-length or on export reels with optional colour coding, jacket printing, and factory pre-termination.
What standards and quality certificates accompany 1-PFA-322 550°F Wireline?
1-PFA-322 550°F Wireline conforms to API RP 9A, ICEA S-73-532, IEEE 1580 (ref.) (288 °C / 550 °F HPHT) and ships with an EN 10204 3.1 routine factory test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for 1-PFA-322 550°F Wireline

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

1-PFA-322 550 °F (288 °C) PFA Armored Wireline Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote