Contact

UL AWM 1333 300 V 150 °C FEP Thin-Wall Hook-Up WireUL 758 Style 1333 300 V 150 °C thin-wall FEP fluoropolymer wire

UL 1333 150 °C 300 V FEP combines stranded tinned copper conductors with compact 10-mil blue FEP fluoropolymer insulation for high-density 300 V electronic cabinets, lighting fixtures, and industrial sensors.

Flame-retardant
Oil-resistant
Approved
Order designation
UL 1333 300V FEP 1×22 AWG
Outer Ø
1.3 mm
Max. R20
59.40 Ω/km
Weight
12 kg/km
Min. bend R
7.8 mm
All sizes (8)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300 V
Test voltage 2 kV AC
Temp. (fixed)
-65°C…+150°C
Flexing: -40 °C to +150 °C
Insulation
FEP
Blue 10-mil extruded FEP
Min. bend radius
6 × OD
Fixed & equipment routing
Conductor
Tinned Cu · Cl.K
Per UL AWM Style 1333
Size range
1×28–1×14
8 standard configurations

Typical values for this cable type, based on UL AWM Style 1333 · UL 758 · CSA AWM I A/B — confirmed in the datasheet and quotation for your order.

Application fit

Is UL 1333 300V FEP right for your machine?

UL 1333 150 °C 300 V FEP combines stranded tinned copper conductors with compact 10-mil blue FEP fluoropolymer insulation for high-density 300 V electronic cabinets, lighting fixtures, and industrial sensors.

Switchgear & control cabinet wiring

Suitable

Compact 300 V FEP profile simplifies high-density routing inside control panels, avionics racks, and equipment chassis.

Furnace, kiln & high-temp zone

Suitable

Thermal-rated 300 V FEP insulation maintains dielectric safety across continuous high-temperature zones up to +150 °C.

Control cabinet & internal panel wiring

Suitable

Compact flame-retardant 300 V FEP geometry routes neatly through dense switchgear ducts, control cabinets, and DIN-rail terminals.

Precision test bench & clean equipment

Suitable

Clean, low-outgassing 300 V FEP construction fits laboratory instruments, precision test benches, and controlled indoor enclosures.

Energy chain / drag chain

Not suitable

300 V FEP construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Immersion & wet locations

Not suitable

300 V FEP outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesIndustrial ovens, kilns & thermal processingAerospace avionics, defence & instrumentationSteelworks, glassworks & foundry equipmentSwitchgear cabinets, motors & heating appliances

Construction

Layer by layer

Representative construction of UL 1333 300V FEP: ASTM B172 / B33 Class K flexible tinned annealed copper, Blue 10-mil extruded FEP fluoropolymer insulation, and Blue 10-mil extruded FEP fluoropolymer outer insulation.

12
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorASTM B172 / B33 Class K flexible tinned annealed copperASTM B172 / B33
2Extruded insulationBlue 10-mil extruded FEP fluoropolymer insulationUL AWM Style 1333

UL 1333 300V FEP Single-Core

Single-conductor high-temperature wire with extruded Blue 10-mil extruded FEP fluoropolymer insulation.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on UL AWM Style 1333 · UL 758 · CSA AWM I A/B. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
300 V
Test voltage
2 kV AC
Conductor
Tinned Cu · Cl.K
Insulation
Blue 10-mil extruded FEP fluoropolymer
Impedance / insulation
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-65 °C to +150 °C
Temp. range (flexing)
-40 °C to +150 °C
Peak / short-circuit
+160 °C (5 s)
Min. bending radius
6 × OD (fixed)

Resistance

Flame / fire rating
UL VW-1 / FT1 Flame
Thermal / chemical
Compact 10-mil FEP
Mechanical / special
Chemical & Moisture Proof
Outer finish
Blue 10-mil extruded FEP fluoropolymer

Sizes

Single-Core High-Temp Hook-Up Wire (AWG)
Conductor
AWG
Outer Ø ≈
mm
Max. R20
Ω/km
Metal index
kg/km
Weight ≈
kg/km
Min. bend R
6×D mm
1×28 AWG0.9238.00195.4
1×26 AWG1.0150.00196.0
1×24 AWG1.194.202116.6
1×22 AWG1.359.403127.8
1×20 AWG1.536.705149.0
1×18 AWG1.723.2071710.2
1×16 AWG2.014.70122312.0
1×14 AWG2.49.07193514.0
  • Conductor DC resistance R20 at 20 °C per ASTM B172 / B33.
  • Minimum bending radius calculated at 6 × nominal outer diameter (OD). Custom core counts and lengths available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
High-voltage dielectric spark / withstand test2 kV AC without breakdownEvery manufactured drum
Conductor DC resistance checkPer ASTM B172 / B33 at 20 °CEvery reel / drum length
Sample tests
Dimensional, wall thickness & thermal agingRated -65 °C to +150 °C continuousPer production lot
Flame, chemical & mechanical qualificationUL VW-1 / FT1 Flame · Compact 10-mil FEPType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL AWM Style 1333UL 758CSA AWM I A/BEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

UL 1333 300V FEP 300 V TEBAOFLEX.COM [UL AWM Style 1333] [Size] [Metre mark]
Delivery form
Spools, coils or wooden export reels
Standard lengths
305 m (1,000 ft) · 500 m · 1,000 m
MOQ
100 m (stock sizes) · 500 m (production)
Lead time
2–3 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-22
Updated
2026-11-22

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes UL 1333 300V FEP suited for 300 V and -65 °C to +150 °C operation?
UL 1333 300V FEP combines ASTM B172 / B33 Class K flexible tinned annealed copper with Blue 10-mil extruded FEP fluoropolymer insulation and Blue 10-mil extruded FEP fluoropolymer outer insulation. Compact 10-mil FEP insulation cuts wire-duct congestion while resisting oil mist and 150 °C enclosure heat.
What is the minimum bending radius of UL 1333 300V FEP during installation?
Maintain a minimum bending radius of 6 × OD across -40 °C to +150 °C flexing temperatures to protect conductor stranding and dielectric integrity.
Can UL 1333 300V FEP be supplied in custom lengths, colours, or core configurations?
Yes. TEBAOFLEX supplies UL 1333 300V FEP cut-to-length or on export reels with optional colour coding, jacket printing, and factory pre-termination.
What standards and quality certificates accompany UL 1333 300V FEP?
UL 1333 300V FEP conforms to UL AWM Style 1333, UL 758, CSA AWM I A/B (UL VW-1 / FT1 Flame) and ships with an EN 10204 3.1 routine factory test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for UL 1333 300V FEP

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

UL AWM 1333 300 V 150 °C FEP Thin-Wall Hook-Up Wire

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote