Furnace, kiln & high-temp zone
Thermal-rated 300/500 V SiR insulation maintains dielectric safety across continuous high-temperature zones up to +180 °C.
Product
SiHF-GL-P / SiHF-GLS-P upgrades multi-core 180 °C silicone cable with a fibreglass wrapping (GL) and galvanized steel wire outer braid (P) to resist slag, impact, and mechanical abrasion in glassworks and steel mills.
Typical values for this cable type, based on DIN VDE 0250-816 · IEC 60228 Class 5 · IEC 60754-1 Halogen-Free — confirmed in the datasheet and quotation for your order.
Application fit
SiHF-GL-P / SiHF-GLS-P upgrades multi-core 180 °C silicone cable with a fibreglass wrapping (GL) and galvanized steel wire outer braid (P) to resist slag, impact, and mechanical abrasion in glassworks and steel mills.
Thermal-rated 300/500 V SiR insulation maintains dielectric safety across continuous high-temperature zones up to +180 °C.
Stable 300/500 V SiR construction routes cleanly in stationary conduits, raceways, ducts, and equipment bays.
Thermal-aged 300/500 V SiR insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.
Rugged 300/500 V SiR construction handles stationary heavy-plant cable trenches, rolling-mill feeders, and industrial power bays.
300/500 V SiR construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR300/500 V SiR outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.
Use EMC-VFD Submersible EPDMConstruction
Representative construction of SiHF-GL-P / SiHF-GLS-P: IEC 60228 Class 5 flexible tinned annealed copper, Colour-coded 180 °C halogen-free silicone rubber (inner silicone sheath), and Galvanized steel wire outer braid (P) over fibreglass & silicone inner sheath.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | IEC 60228 Class 5 flexible tinned annealed copperIEC 60228 Class 5 |
| 2 | Core insulation | Colour-coded 180 °C halogen-free silicone rubber (inner silicone sheath)DIN VDE 0250-816 |
| 3 | Inner silicone sheath | Halogen-free 180 °C red-oxide silicone rubber inner sheathDIN VDE 0250-816 |
| 4 | Fibreglass protective wrap | Woven fibreglass thermal and mechanical separator braid (GL)DIN VDE 0250-816 |
| 5 | Galvanized steel wire braid | Galvanized steel wire outer braid (P) over fibreglass & silicone inner sheath180 °C Silicone + Steel Braid |
Colour-coded 180 °C silicone cores in inner silicone sheath, fibreglass wrap (GL), and galvanized steel wire outer braid (P).
Technical data
Sizes
| Cores × mm² | Outer Ø ≈ mm | Max. R20 Ω/km | Metal index kg/km | Weight ≈ kg/km | Min. bend R 10×D mm |
|---|---|---|---|---|---|
| 2×0.75 mm² | 7.8 | 26.73 | 14 | 98 | 78 |
| 3G0.75 mm² | 8.2 | 26.73 | 22 | 118 | 82 |
| 3G1.0 mm² | 8.8 | 20.05 | 29 | 141 | 88 |
| 4G1.0 mm² | 9.6 | 20.05 | 38 | 173 | 96 |
| 3G1.5 mm² | 9.6 | 13.67 | 43 | 180 | 96 |
| 4G1.5 mm² | 10.4 | 13.67 | 58 | 223 | 104 |
| 5G1.5 mm² | 11.2 | 13.67 | 72 | 265 | 112 |
| 4G2.5 mm² | 12.0 | 8.20 | 96 | 324 | 120 |
| 5G2.5 mm² | 13.0 | 8.20 | 120 | 390 | 130 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| High-voltage dielectric spark / withstand test | 2 kV AC without breakdown | Every manufactured drum |
| Conductor DC resistance check | Per IEC 60228 Class 5 at 20 °C | Every reel / drum length |
| Sample tests | ||
| Dimensional, wall thickness & thermal aging | Rated -60 °C to +180 °C continuous | Per production lot |
| Flame, chemical & mechanical qualification | 180 °C Silicone + Steel Braid · Mechanical & Slag Armour | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.