Contact

SAE J2031 Class E 7 mm 220 °C Silicone Ignition Cable7 mm 40 kV SAE J2031 Class E automotive & industrial engine ignition wire

SAE J2031 Class E 7 mm Ignition combines an EMI-suppressing spiral alloy/carbon core with EPDM/silicone insulation, reinforcing fibreglass braid, and a black 220 °C silicone outer jacket for industrial gas engines and vehicles.

Flame-retardant
Oil-resistant
Approved
Order designation
SAE J2031 Class E Ignition Cable 7 mm · Spiral Alloy (2 kΩ/m)
Outer Ø
7.0 mm
Max. R20
2,000,000.00 Ω/km
Weight
68 kg/km
Min. bend R
56 mm
All sizes (4)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
40 kV
Test voltage 40 kV DC
Temp. (fixed)
-55°C…+220°C
Flexing: -40 °C to +220 °C
Insulation
SiR
High-dielectric inner elastomer +
Min. bend radius
8 × OD
Fixed & equipment routing
Conductor
Spiral EMI Alloy
Per SAE J2031 Class E
Size range
7 mm–8.5 mm
4 standard configurations

Typical values for this cable type, based on SAE J2031 Class E · ISO 3808 Class E · ISO 6856 — confirmed in the datasheet and quotation for your order.

Application fit

Is SAE J2031 Class E Ignition Cable right for your machine?

SAE J2031 Class E 7 mm Ignition combines an EMI-suppressing spiral alloy/carbon core with EPDM/silicone insulation, reinforcing fibreglass braid, and a black 220 °C silicone outer jacket for industrial gas engines and vehicles.

Furnace, kiln & high-temp zone

Suitable

Thermal-rated 40 kV SiR insulation maintains dielectric safety across continuous high-temperature zones up to +220 °C.

Fixed installation

Suitable

Stable 40 kV SiR construction routes cleanly in stationary conduits, raceways, ducts, and equipment bays.

Vehicle engine bay & HV bus harness

Suitable

Fluid- and heat-resistant 40 kV SiR thin-wall design routes cleanly through compact vehicle engine bays and HV chassis looms.

High-temperature boiler & thermal plant

Suitable

Thermal-aged 40 kV SiR insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.

Energy chain / drag chain

Not suitable

40 kV SiR construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Immersion & wet locations

Not suitable

40 kV SiR outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesAutomotive & Commercial VehiclesIndustrial oil/gas burners & steam boilersStationary CHP gas engines & cogenerationAutomotive, motorsport & heavy-duty ignitionX-ray, laser & high-voltage DC power supplies

Construction

Layer by layer

Representative construction of SAE J2031 Class E Ignition Cable: Spiral wire-wound stainless resistance alloy EMI-suppression core over carbon-ferrite center, High-dielectric inner elastomer + reinforcing fibreglass braid, and Black 7 mm 220 °C fuel- & heat-resistant silicone outer jacket.

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorSpiral wire-wound stainless resistance alloy EMI-suppression core over carbon-ferrite centerSAE J2031 / ISO 3808
2Inner HV dielectricHigh-dielectric inner elastomer + reinforcing fibreglass braidSAE J2031 Class E
3Reinforcing fibreglass braidWoven high-tensile fibreglass reinforcing braidSAE J2031 Class E
4Outer silicone jacketBlack 7 mm 220 °C fuel- & heat-resistant silicone outer jacket40 kV Breakdown Rating

SAE J2031 Class E Ignition Cable Dual-Silicone HV

Spiral wire-wound EMI-suppression core inside dual-layer high-dielectric silicone reinforced with fibreglass braid.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on SAE J2031 Class E · ISO 3808 Class E · ISO 6856. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
40 kV
Test voltage
40 kV DC
Conductor
Spiral EMI Alloy
Insulation
High-dielectric inner elastomer +
Impedance / insulation
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-55 °C to +220 °C
Temp. range (flexing)
-40 °C to +220 °C
Peak / short-circuit
+220 °C (short-term)
Min. bending radius
8 × OD (fixed)

Resistance

Flame / fire rating
40 kV Breakdown Rating
Thermal / chemical
220 °C Class E Silicone
Mechanical / special
Fuel, Oil & Ozone Proof
Outer finish
Black 7 mm 220 °C fuel- & heat-resistant

Sizes

40 kV SAE J2031 Class E Ignition Wire
Outer Ø ·
Core Type
Outer Ø ≈
mm
Max. R20
Ω/km
Metal index
kg/km
Weight ≈
kg/km
Min. bend R
8×D mm
7 mm · Spiral Alloy (2 kΩ/m)7.02,000,000.0096856
7 mm · Carbon Core (10 kΩ/m)7.010,000,000.0046256
8 mm · Spiral Alloy (1.5 kΩ/m)8.01,500,000.00108664
8.5 mm · Heavy Silicone (1 kΩ/m)8.51,000,000.00119868
  • Conductor DC resistance R20 at 20 °C per SAE J2031 / ISO 3808.
  • Minimum bending radius calculated at 8 × nominal outer diameter (OD). Custom core counts and lengths available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
High-voltage dielectric spark / withstand test40 kV DC without breakdownEvery manufactured drum
Conductor DC resistance checkPer SAE J2031 / ISO 3808 at 20 °CEvery reel / drum length
Sample tests
Dimensional, wall thickness & thermal agingRated -55 °C to +220 °C continuousPer production lot
Flame, chemical & mechanical qualification40 kV Breakdown Rating · 220 °C Class E SiliconeType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

SAE J2031 Class EISO 3808 Class EISO 6856EN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

SAE J2031 Class E Ignition Cable 40 kV TEBAOFLEX.COM [SAE J2031 Class E] [Size] [Metre mark]
Delivery form
Spools, coils or wooden export reels
Standard lengths
100 m · 500 m · 1,000 m
MOQ
100 m (stock sizes) · 500 m (production)
Lead time
2–3 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-22
Updated
2026-11-22

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes SAE J2031 Class E Ignition Cable suited for 40 kV and -55 °C to +220 °C operation?
SAE J2031 Class E Ignition Cable combines Spiral wire-wound stainless resistance alloy EMI-suppression core over carbon-ferrite center with High-dielectric inner elastomer + reinforcing fibreglass braid and Black 7 mm 220 °C fuel- & heat-resistant silicone outer jacket. Meets SAE J2031 Class E 220 °C thermal aging and EMI suppression standards for commercial gas engines.
What is the minimum bending radius of SAE J2031 Class E Ignition Cable during installation?
Maintain a minimum bending radius of 8 × OD across -40 °C to +220 °C flexing temperatures to protect conductor stranding and dielectric integrity.
Can SAE J2031 Class E Ignition Cable be supplied in custom lengths, colours, or core configurations?
Yes. TEBAOFLEX supplies SAE J2031 Class E Ignition Cable cut-to-length or on export reels with optional colour coding, jacket printing, and factory pre-termination.
What standards and quality certificates accompany SAE J2031 Class E Ignition Cable?
SAE J2031 Class E Ignition Cable conforms to SAE J2031 Class E, ISO 3808 Class E, ISO 6856 (40 kV Breakdown Rating) and ships with an EN 10204 3.1 routine factory test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for SAE J2031 Class E Ignition Cable

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

SAE J2031 Class E 7 mm 220 °C Silicone Ignition Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp