Contact

Intemp 250 BS G210 +250°C High-Temperature WireIntemp 250 BS G210 +250°C High-Temperature Wire manufactured to Generally to BS G210, rated 0.6/1 kV and -55°C to +250°C with a 10 × OD minimum bending radius for oil, gas & petrochemical installations.

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Flame-retardant
Oil-resistant
Approved
Order designation
Intemp 250 BS G210 +250°C High-Temperature (1×4 mm²)
Outer diameter
4.5 mm
Cable weight
48 kg/km
Min. bend radius
45 mm
Conductor & shield
Stranded Nickel-Plated Copper
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Generally to BS G210
Temperature
-55°C to +250°C
Fixed / flex duty
Min. bend radius
10 × OD
4.5–6.2 mm
Screening
Unshielded
Fixed / flex duty
Outer sheath
High-Temp Jacket
Thermal & chemical resistant compound
Core / size range
3 sizes
3 standard configurations

Typical values for this cable type, based on Reference specification per Generally to BS G210 (Intemp 250 BS G210 +250°C High-Temperature) — confirmed in the datasheet and quotation for your order.

Application fit

Is Intemp 250 BS G210 +250°C High-Temperature right for your machine?

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Fixed installation

Suitable

Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.

Motor stator, traction & converter leads

Suitable

Flexible stranded conductors withstand equipment vibration, mobile hook-ups and routine flexing.

Energy chain / drag chain

With conditions

Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.

Offshore platform & shipboard deck trays

Suitable

Outer sheath compound resists industrial oils, moisture ingress, abrasion and outdoor weathering.

Vertical / spreader reel

Not suitable

Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.

Use TRA 0.6/1 kV PUR Reeling Cable

Aerospace avionics bay & airframe loom

Suitable

Low-weight, high-temperature 0.6/1 kV PFA construction meets compact avionics racks, flight-control looms, and aerospace harnesses.

Typical machinesAerospace & AvionicsPower distribution & utility networksRailways, tunnels & public infrastructureProcess instrumentation & oil/gas skidsIndustrial automation & control cabinetsRenewable energy, marine & heavy industry

Construction

Layer by layer

Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

Intemp 250 BS G210 +250°C High-Temperature – Layered cable cutaway
Layer cutaway
#LayerMaterial & reference
1Conductor1×4.0 mm² (56/0.30 mm) Class 5 Nickel-Plated Cu
2Insulation & Core IdentificationPFA (Perfluoroalkoxy) +250°C fluoropolymer primary insulation
3Screen / Bedding / Armour LayerHigh-temperature phlogopite mica glass fire-barrier tape
4Outer Protective SheathNatural varnished glass fibre braided outer sheath (+250°C, OD 4.5 mm)

1×4 mm²

Stranded Nickel-Plated Copper · Outer diameter 4.5 mm

1×6 mm²

Stranded Nickel-Plated Copper · Outer diameter 5.3 mm

1×10 mm²

Stranded Nickel-Plated Copper · Outer diameter 6.2 mm

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on Reference specification per Generally to BS G210 (Intemp 250 BS G210 +250°C High-Temperature). Values for your order are confirmed in the datasheet and quotation.

Electrical

Nominal / reference voltage
0.6/1 kV
Conductor & core insulation
1×4.0 mm² (56/0.30 mm) Class 5 Nickel-Plated Cu · PFA (Perfluoroalkoxy) +250°C fluoropolymer primary insulation
Routine dielectric / continuity test
100% factory drum spark & continuity verified

Thermal

Operating temperature range
-55°C to +250°C
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s conductor thermal limit)
Flame & fire performance
Generally to BS G210

Mechanical

Minimum bending radius
10 × OD
Screening / armour architecture
High-temperature phlogopite mica glass fire-barrier tape
Outer sheath material & colour
Natural varnished glass fibre braided outer sheath (+250°C, OD 4.5 mm)

Reference standards

Reference standard
Generally to BS G210
Hazardous Substance Compliance
CE, UKCA, RoHS 2 (2011/65/EU) & REACH SVHC compliant
Quality & Batch Traceability
EN 10204 3.1 Factory Inspection Certificate

Sizes

Sizes & engineering data

Representative configurations from the series specification; select a row to prefill the quotation tool.

All sizes
ConfigurationConductor & shieldInsulation / wallOuter sheathOuter diameter
mm
Min. bend radius
mm
Max. conductor resistance @ 20 °C
Ω/km
Copper weight
kg/km
Cable weight
kg/km
Key electrical / optical ratingPart designationEnquiry
Intemp 250 BS G210 +250°C High-Temperature
1×4 mm²Stranded Nickel-Plated CopperPFA +250°C fluoropolymer primary insulationHigh-Temp Jacket4.5454.5325.04834 AIntemp 250 BS G210 +250°C High-Temperature (1×4 mm²)
1×6 mm²Stranded Nickel-Plated CopperPFA +250°C fluoropolymer primary insulationHigh-Temp Jacket5.3533.0234.36643 AIntemp 250 BS G210 +250°C High-Temperature (1×6 mm²)
1×10 mm²Stranded Nickel-Plated CopperPFA +250°C fluoropolymer primary insulationHigh-Temp Jacket6.2621.8147.39160 AIntemp 250 BS G210 +250°C High-Temperature (1×10 mm²)
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Dimensions and weights are nominal manufacturing targets subject to standard production tolerances.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance & continuityWithin maximum Ω/km limit at 20 °C per IEC 60228 / BS EN 60228Every manufactured drum length
Dielectric withstand / spark testNo breakdown across insulation, screen or armourEvery manufactured drum length
Sample tests
Vertical flame propagation & jacket qualificationSelf-extinguishing and compliant with reference standard limitsType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

Generally to BS G210 CompliantEN 10204 3.1 Factory Test CertificateCE, UKCA, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

INTEMP 250 BS G210 +250°C HIGH-TEMPERATURE WIRE / TEBAOFLEX.COM — sequential metre marking
Delivery form
Heavy-duty export fumigated wooden drums or steel reels with moisture-sealed ends
Standard lengths
250 m, 500 m, 1000 m continuous drum lengths or custom cut-to-length runs
MOQ
100 m (standard configurations) · 300 m (custom builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-04
Updated
2026-11-04

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is Intemp 250 BS G210 +250°C High-Temperature designed for?
Intemp 250 BS G210 +250°C High-Temperature is engineered for oil, gas & petrochemical installations under Generally to BS G210, operating over -55°C to +250°C with a minimum bending radius of 10 × OD.
How is Intemp 250 BS G210 +250°C High-Temperature constructed across its layers?
Its 4-layer architecture combines 1×4.0 mm² (56/0.30 mm) Class 5 Nickel-Plated Cu with PFA (Perfluoroalkoxy) +250°C fluoropolymer primary insulation, High-temperature phlogopite mica glass fire-barrier tape and Natural varnished glass fibre braided outer sheath (+250°C, OD 4.5 mm).
What standards and routine factory tests apply to Intemp 250 BS G210 +250°C High-Temperature?
Every manufactured drum is tested to Generally to BS G210 for conductor continuity, dielectric voltage withstand and sheath integrity, supplied with an EN 10204 3.1 inspection certificate.
What sizes and drum lengths are available for Intemp 250 BS G210 +250°C High-Temperature?
Representative sizes include 1×4 mm², 1×6 mm² and 1×10 mm², supplied on 250 m, 500 m or 1,000 m export drums or custom cut lengths.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for Intemp 250 BS G210 +250°C High-Temperature

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

Intemp 250 BS G210 +250°C High-Temperature Wire

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote