Thermal-rated 300 V FEP insulation maintains dielectric safety across continuous high-temperature zones up to +200 °C.
Product
FEP/C/FEP Multi-Pair KX bundles multiple twisted Type KX NiCr/NiAl thermocouple pairs in FEP insulation with overall ≥ 85% copper braid and an IEC 60584 green FEP jacket for multi-zone 200 °C furnace monitoring.
Typical values for this cable type, based on IEC 60584-3 Type KX · ASTM E230 · DIN 43710 — confirmed in the datasheet and quotation for your order.
Application fit
FEP/C/FEP Multi-Pair KX bundles multiple twisted Type KX NiCr/NiAl thermocouple pairs in FEP insulation with overall ≥ 85% copper braid and an IEC 60584 green FEP jacket for multi-zone 200 °C furnace monitoring.
Thermal-rated 300 V FEP insulation maintains dielectric safety across continuous high-temperature zones up to +200 °C.
Stable 300 V FEP construction routes cleanly in stationary conduits, raceways, ducts, and equipment bays.
Thermal-aged 300 V FEP insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.
Low-noise 300 V FEP pair/core geometry preserves 4–20 mA and sensor signals from field transmitters to DCS marshalling cabinets.
300 V FEP construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR300 V FEP outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.
Use EMC-VFD Submersible EPDMConstruction
Representative construction of FEP/C/FEP Multi-Pair KX: Matched ASTM E230 Type K Chromel (NiCr +) / Alumel (NiAl -) thermocouple alloy conductors, Extruded FEP fluoropolymer (IEC green + / white - pairs), and Green (IEC 60584 KX) chemical-resistant extruded FEP outer sheath.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | Matched ASTM E230 Type K Chromel (NiCr +) / Alumel (NiAl -) thermocouple alloy conductorsASTM E230 / IEC 60584 |
| 2 | Dielectric / core insulation | Extruded FEP fluoropolymer (IEC green + / white - pairs)IEC 60584-3 Type KX |
| 3 | Core assembly & separator | Concentric cabled core assembly with low-friction fleece/polyester separator tapeIEC 60584-3 Type KX |
| 4 | Metallic EMC screen | Overall ≥ 85% tinned copper wire braid EMC shieldEMC ≥ 85% shield |
| 5 | Outer sheath | Green (IEC 60584 KX) chemical-resistant extruded FEP outer sheath200 °C Continuous FEP |
IEC 60584 green (+) / white (-) twisted Type KX thermocouple pairs under overall EMC braid.
Technical data
Sizes
| Pairs × mm² | Outer Ø ≈ mm | Max. R20 Ω/km | Metal index kg/km | Weight ≈ kg/km | Min. bend R 10×D mm |
|---|---|---|---|---|---|
| 2P×0.5 mm² (Type KX) | 7.2 | 1,960.00 | 26 | 82 | 72 |
| 4P×0.5 mm² (Type KX) | 8.8 | 1,960.00 | 46 | 134 | 88 |
| 6P×0.5 mm² (Type KX) | 10.4 | 1,960.00 | 68 | 188 | 104 |
| 8P×0.5 mm² (Type KX) | 11.8 | 1,960.00 | 90 | 242 | 118 |
| 12P×0.5 mm² (Type KX) | 14.0 | 1,960.00 | 134 | 345 | 140 |
| 4P×1.0 mm² (Type KX) | 10.6 | 980.00 | 86 | 215 | 106 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| High-voltage dielectric spark / withstand test | 1.5 kV AC without breakdown | Every manufactured drum |
| Conductor DC resistance check | Per ASTM E230 / IEC 60584 at 20 °C | Every reel / drum length |
| Sample tests | ||
| Dimensional, wall thickness & thermal aging | Rated -75 °C to +200 °C continuous | Per production lot |
| Flame, chemical & mechanical qualification | 200 °C Continuous FEP · ≥ 85% EMC Braid Screen | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.