Furnace, kiln & high-temp zone
Thermal-rated 300 V SiR insulation maintains dielectric safety across continuous high-temperature zones up to +200 °C.
Product
UL 3122 / SF-1 300 V combines stranded tinned copper, 200 °C extruded silicone rubber insulation, and a lacquered fibreglass outer braid for commercial lighting fixtures, ovens, and North American heating appliances.
Typical values for this cable type, based on UL AWM Style 3122 · UL 66 Type SF-1 · CSA AWM I A/B — confirmed in the datasheet and quotation for your order.
Application fit
UL 3122 / SF-1 300 V combines stranded tinned copper, 200 °C extruded silicone rubber insulation, and a lacquered fibreglass outer braid for commercial lighting fixtures, ovens, and North American heating appliances.
Thermal-rated 300 V SiR insulation maintains dielectric safety across continuous high-temperature zones up to +200 °C.
Flexible 300 V SiR heat-resistant insulation terminates cleanly inside motor junction boxes, heaters, and hot windings.
Thermal-aged 300 V SiR insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.
Compact flame-retardant 300 V SiR geometry routes neatly through dense switchgear ducts, control cabinets, and DIN-rail terminals.
300 V SiR construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR300 V SiR outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.
Use EMC-VFD Submersible EPDMConstruction
Representative construction of UL 3122 / SF-1 Wire: ASTM B172 / B33 Class K flexible tinned annealed copper, 200 °C extruded silicone rubber primary insulation, and Tan lacquered fibreglass outer braid over silicone (silicone/glass).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | ASTM B172 / B33 Class K flexible tinned annealed copperASTM B172 / B33 |
| 2 | Primary insulation | 200 °C extruded silicone rubber primary insulationUL AWM Style 3122 |
| 3 | Fibreglass outer braid | Tan lacquered fibreglass outer braid over silicone (silicone/glass)UL VW-1 / FT2 Flame |
Single high-temperature conductor insulated in silicone rubber and protected by a varnished fibreglass outer braid.
Technical data
Sizes
| Conductor AWG | Outer Ø ≈ mm | Max. R20 Ω/km | Metal index kg/km | Weight ≈ kg/km | Min. bend R 6×D mm |
|---|---|---|---|---|---|
| 1×24 AWG | 1.9 | 94.20 | 2 | 11 | 11.4 |
| 1×22 AWG | 2.1 | 59.40 | 3 | 12 | 13.0 |
| 1×20 AWG | 2.3 | 36.70 | 5 | 14 | 14.0 |
| 1×18 AWG | 2.5 | 23.20 | 7 | 18 | 15.0 |
| 1×16 AWG | 2.9 | 14.70 | 12 | 28 | 17.0 |
| 1×14 AWG | 3.3 | 9.07 | 19 | 41 | 20.0 |
| 1×12 AWG | 3.8 | 5.71 | 30 | 62 | 23.0 |
| 1×10 AWG | 4.4 | 3.59 | 48 | 94 | 26.0 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| High-voltage dielectric spark / withstand test | 2 kV AC without breakdown | Every manufactured drum |
| Conductor DC resistance check | Per ASTM B172 / B33 at 20 °C | Every reel / drum length |
| Sample tests | ||
| Dimensional, wall thickness & thermal aging | Rated -60 °C to +200 °C continuous | Per production lot |
| Flame, chemical & mechanical qualification | UL VW-1 / FT2 Flame · 200 °C Silicone + Glass | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.