Fixed installation
Stable 230 V HT construction routes cleanly in stationary conduits, raceways, ducts, and equipment bays.
Product
ELSR-SH 250 °C Heating Cable embeds dual nickel-plated copper bus wires in a conductive PTC self-regulating heating matrix with fluoropolymer insulation, tinned copper braid, and a red chemical-proof fluoropolymer jacket.
Typical values for this cable type, based on IEC 60079-30-1 · EN 62395-1 · ATEX / IECEx (ref.) — confirmed in the datasheet and quotation for your order.
Application fit
ELSR-SH 250 °C Heating Cable embeds dual nickel-plated copper bus wires in a conductive PTC self-regulating heating matrix with fluoropolymer insulation, tinned copper braid, and a red chemical-proof fluoropolymer jacket.
Stable 230 V HT construction routes cleanly in stationary conduits, raceways, ducts, and equipment bays.
Thermal-rated 230 V HT insulation maintains dielectric safety across continuous high-temperature zones up to +250 °C.
Thermal-output 230 V HT construction provides uniform freeze protection and process temperature maintenance along insulated pipelines.
Thermal-aged 230 V HT insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.
230 V HT construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR230 V HT build lacks anti-torsion tensile reinforcement for motorised drum reeling; select a dedicated reeling cable.
Use RG / RG-D (N)SHTOEU-JConstruction
Representative construction of ELSR-SH 250°C Heating Cable: Dual nickel-plated copper bus wires embedded in conductive PTC self-regulating heating core, Self-regulating conductive PTC heating core + fluoropolymer inner jacket, and Red chemical- & steam-purge-resistant fluoropolymer outer jacket.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | Dual nickel-plated copper bus wires embedded in conductive PTC self-regulating heating coreIEC 60079-30-1 |
| 2 | Dielectric / core insulation | Self-regulating conductive PTC heating core + fluoropolymer inner jacketIEC 60079-30-1 |
| 3 | Metallic EMC screen | Protective tinned copper wire braid (ground-fault & mechanical shield)EMC ≥ 85% shield |
| 4 | Outer sheath | Red chemical- & steam-purge-resistant fluoropolymer outer jacket250 °C Max Exposure |
Parallel nickel-plated copper bus wires embedded in conductive PTC matrix under fluoropolymer insulation and braid.
Technical data
Sizes
| Output · Bus Size | Outer Ø ≈ mm | Max. R20 Ω/km | Metal index kg/km | Weight ≈ kg/km | Min. bend R 6×D mm |
|---|---|---|---|---|---|
| 15 W/m · 2×1.23 mm² (230 V) | 6.4 | 15.60 | 28 | 128 | 38 |
| 30 W/m · 2×1.23 mm² (230 V) | 6.4 | 15.60 | 28 | 132 | 38 |
| 45 W/m · 2×1.23 mm² (230 V) | 6.6 | 15.60 | 30 | 138 | 40 |
| 60 W/m · 2×1.23 mm² (230 V) | 6.8 | 15.60 | 32 | 144 | 41 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| High-voltage dielectric spark / withstand test | 2 kV AC without breakdown | Every manufactured drum |
| Conductor DC resistance check | Per IEC 60079-30-1 at 20 °C | Every reel / drum length |
| Sample tests | ||
| Dimensional, wall thickness & thermal aging | Rated -60 °C to +250 °C continuous | Per production lot |
| Flame, chemical & mechanical qualification | 250 °C Max Exposure · Self-Regulating PTC Matrix | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.