Switchgear & control cabinet wiring
Compact 600/1000 V PTFE profile simplifies high-density routing inside control panels, avionics racks, and equipment chassis.
Product
VDE 5Y PTFE 600/1000 V pairs IEC 60228 Class 5 silver-plated copper with heavy-wall red PTFE (5Y) fluoropolymer insulation rated 600/1000 V and -190 °C to +260 °C for European process heating and switchboards.
Typical values for this cable type, based on DIN VDE 0250 (5Y) · IEC 60228 Class 5 · EN 60332-1-2 — confirmed in the datasheet and quotation for your order.
Application fit
VDE 5Y PTFE 600/1000 V pairs IEC 60228 Class 5 silver-plated copper with heavy-wall red PTFE (5Y) fluoropolymer insulation rated 600/1000 V and -190 °C to +260 °C for European process heating and switchboards.
Compact 600/1000 V PTFE profile simplifies high-density routing inside control panels, avionics racks, and equipment chassis.
Thermal-rated 600/1000 V PTFE insulation maintains dielectric safety across continuous high-temperature zones up to +260 °C.
Thermal-aged 600/1000 V PTFE insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.
Compact flame-retardant 600/1000 V PTFE geometry routes neatly through dense switchgear ducts, control cabinets, and DIN-rail terminals.
600/1000 V PTFE construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR600/1000 V PTFE outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.
Use EMC-VFD Submersible EPDMConstruction
Representative construction of VDE 5Y PTFE 600/1000V: IEC 60228 Class 5 flexible silver-plated annealed copper, Red extruded PTFE (5Y) fluoropolymer insulation, and Red 600/1000 V extruded PTFE (5Y) outer insulation.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | IEC 60228 Class 5 flexible silver-plated annealed copperIEC 60228 Class 5 |
| 2 | Extruded insulation | Red extruded PTFE (5Y) fluoropolymer insulationDIN VDE 0250 (5Y) |
Single-conductor high-temperature wire with extruded Red extruded PTFE (5Y) fluoropolymer insulation.
Technical data
Sizes
| Conductor mm² | Outer Ø ≈ mm | Max. R20 Ω/km | Metal index kg/km | Weight ≈ kg/km | Min. bend R 8×D mm |
|---|---|---|---|---|---|
| 1×0.25 mm² | 1.9 | 81.37 | 2 | 11 | 15 |
| 1×0.5 mm² | 2.1 | 40.09 | 5 | 14 | 17 |
| 1×0.75 mm² | 2.3 | 26.73 | 7 | 17 | 18 |
| 1×1 mm² | 2.5 | 20.05 | 10 | 22 | 20 |
| 1×1.5 mm² | 2.8 | 13.67 | 14 | 30 | 22 |
| 1×2.5 mm² | 3.7 | 8.20 | 24 | 52 | 30 |
| 1×4 mm² | 4.2 | 5.09 | 38 | 76 | 34 |
| 1×6 mm² | 4.8 | 3.39 | 58 | 111 | 38 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| High-voltage dielectric spark / withstand test | 3.5 kV AC without breakdown | Every manufactured drum |
| Conductor DC resistance check | Per IEC 60228 Class 5 at 20 °C | Every reel / drum length |
| Sample tests | ||
| Dimensional, wall thickness & thermal aging | Rated -190 °C to +260 °C continuous | Per production lot |
| Flame, chemical & mechanical qualification | 260 °C Continuous PTFE · Cryogenic to +260 °C | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.