Switchgear & control cabinet wiring
Compact 1000 V PTFE profile simplifies high-density routing inside control panels, avionics racks, and equipment chassis.
Product
MIL-DTL-16878/5 Type EE (NEMA HP3) increases extruded PTFE wall thickness to 15 mil around silver-plated copper conductors for 1000 V high-voltage avionics, microwave supplies, and defence equipment.
Typical values for this cable type, based on MIL-DTL-16878/5 Type EE · NEMA HP3 · ASTM B298 Silver Cu — confirmed in the datasheet and quotation for your order.
Application fit
MIL-DTL-16878/5 Type EE (NEMA HP3) increases extruded PTFE wall thickness to 15 mil around silver-plated copper conductors for 1000 V high-voltage avionics, microwave supplies, and defence equipment.
Compact 1000 V PTFE profile simplifies high-density routing inside control panels, avionics racks, and equipment chassis.
Thermal-rated 1000 V PTFE insulation maintains dielectric safety across continuous high-temperature zones up to +200 °C.
Low-weight, high-temperature 1000 V PTFE construction meets compact avionics racks, flight-control looms, and aerospace harnesses.
Thermal-aged 1000 V PTFE insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.
1000 V PTFE construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR1000 V PTFE outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.
Use EMC-VFD Submersible EPDMConstruction
Representative construction of MIL-DTL-16878/5 Type EE: ASTM B298 Class K stranded silver-plated annealed copper, 15-mil heavy-wall red extruded PTFE fluoropolymer insulation, and Red 15-mil extruded PTFE fluoropolymer outer insulation.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | ASTM B298 Class K stranded silver-plated annealed copperASTM B298 Silver Cu |
| 2 | Extruded insulation | 15-mil heavy-wall red extruded PTFE fluoropolymer insulationMIL-DTL-16878/5 Type EE |
Single-conductor high-temperature wire with extruded 15-mil heavy-wall red extruded PTFE fluoropolymer insulation.
Technical data
Sizes
| Conductor AWG | Outer Ø ≈ mm | Max. R20 Ω/km | Metal index kg/km | Weight ≈ kg/km | Min. bend R 6×D mm |
|---|---|---|---|---|---|
| 1×28 AWG | 0.9 | 238.00 | 1 | 9 | 5.4 |
| 1×26 AWG | 1.0 | 150.00 | 1 | 9 | 6.0 |
| 1×24 AWG | 1.1 | 94.20 | 2 | 11 | 6.6 |
| 1×22 AWG | 1.3 | 59.40 | 3 | 12 | 7.8 |
| 1×20 AWG | 1.5 | 36.70 | 5 | 14 | 9.0 |
| 1×18 AWG | 1.7 | 23.20 | 7 | 17 | 10.2 |
| 1×16 AWG | 2.0 | 14.70 | 12 | 23 | 12.0 |
| 1×14 AWG | 2.4 | 9.07 | 19 | 35 | 14.0 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| High-voltage dielectric spark / withstand test | 5 kV AC without breakdown | Every manufactured drum |
| Conductor DC resistance check | Per ASTM B298 Silver Cu at 20 °C | Every reel / drum length |
| Sample tests | ||
| Dimensional, wall thickness & thermal aging | Rated -65 °C to +200 °C continuous | Per production lot |
| Flame, chemical & mechanical qualification | 1000 V Heavy-Wall PTFE · 200 °C Continuous | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.