Furnace, kiln & high-temp zone
PEEK insulation and nickel-plated copper withstand +250 °C continuous operation and UHV chamber bake-out.
Product
HSC-7.5-2K2SA 7.5 kVDC vacuum- and radiation-resistant parallel twin-circuit cable pairing an AWG 22 nickel-plated copper PEEK-insulated 7.5 kVDC coaxial unit with an AWG 22 PEEK LV return core under a common V2A stainless-steel wire braid.
Typical values for this cable type, based on IEC 60544 / DIN VDE 0250 — confirmed in the datasheet and quotation for your order.
Application fit
HSC-7.5-2K2SA 7.5 kVDC vacuum- and radiation-resistant parallel twin-circuit cable pairing an AWG 22 nickel-plated copper PEEK-insulated 7.5 kVDC coaxial unit with an AWG 22 PEEK LV return core under a common V2A stainless-steel wire braid.
PEEK insulation and nickel-plated copper withstand +250 °C continuous operation and UHV chamber bake-out.
Halogen-free, low-outgassing PEEK and V2A stainless braid rated for ionizing radiation up to 100 MGy.
Parallel figure-8 twin profile integrates a screened 7.5 kVDC line and an auxiliary LV sensing/filament line.
Semi-rigid PEEK dielectric is designed for static UHV and nuclear routing, not continuous drum reeling.
HFPS-3020-19Construction
Shown: HSC-7.5-2K2SA (IEC 60544 / DIN VDE 0250) featuring hv unit (7.5 kvdc), parallel lv unit and outer mechanical & emc braid (3-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | HV Unit (7.5 kVDC) | AWG 22 (19 x 0.16 mm) nickel-plated copper conductor, 7.5 kVDC PEEK dielectric, nickel-plated copper braid screen, and thin PEEK sub-jacketIEC 60544 / DIN VDE 0250 |
| 2 | Parallel LV Unit | AWG 22 (19 x 0.16 mm, 0.38 mm²) nickel-plated copper low-voltage return/sense core with extruded PEEK insulation laid parallel to HV unitIEC 60544 / DIN VDE 0250 |
| 3 | Outer Mechanical & EMC Braid | Overall V2A (AISI 304) stainless-steel wire braid enclosing the parallel twin assembly for ultra-high vacuum (UHV), radiation, and +250 °C serviceIEC 60544 / DIN VDE 0250 |
Built to IEC 60544 / DIN VDE 0250 with hv unit (7.5 kvdc) and outer mechanical & emc braid
Available in custom drum lengths, core counts or factory-terminated assemblies
Supplied with EN 10204 3.1 routine electrical, dielectric & dimensional inspection report
Technical data
Sizes
Manufactured to IEC 60544 / DIN VDE 0250 for heavy-duty industrial and specialty engineering systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Weight ≈ kg/km | Tensile load kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| HSC-7.5-2K2SA Construction Schedule (−60…+250 °C) | |||||||
| HSC-5.0-2K2SA (5.0 kVDC + LV PEEK) | 2 × AWG 22 (0.38 mm²) | 19×0.16 mm NPC + V2A braid | 4.8 | 38 | 0.4 | 48 | |
| HSC-7.5-2K2SA (7.5 kVDC + LV PEEK) | 2 × AWG 22 (0.38 mm²) | 19×0.16 mm NPC + V2A braid | 5.6 | 49 | 0.5 | 56 | |
| HSC-10-2K2SA (10 kVDC + LV PEEK) | 2 × AWG 20 (0.61 mm²) | 19×0.20 mm NPC + V2A braid | 6.8 | 68 | 0.7 | 68 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Capacity | Operating temp. |
|---|---|---|---|
| 2 × AWG 22 (5.0 kVDC + LV) | 51.50 | 5.0 kVDC HV / 600 V LV | −60…+250 °C |
| 2 × AWG 22 (7.5 kVDC + LV) | 51.50 | 7.5 kVDC HV / 600 V LV | −60…+250 °C |
| 2 × AWG 20 (10 kVDC + LV) | 32.40 | 10 kVDC HV / 600 V LV | −60…+250 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & dimensional verification (IEC 60544 / DIN VDE 0250) | Electrical parameters and outer diameter within IEC 60544 / DIN VDE 0250 tolerances | Every manufactured drum / length |
| High-voltage dielectric & insulation resistance test (IEC 60544 / DIN VDE 0250) | Zero dielectric breakdown and verified insulation resistance over full length | Every manufactured drum / length |
| Sample tests | ||
| Thermal ageing, mechanical flexing & environmental qualification (IEC 60544 / DIN VDE 0250) | Verified structural and dielectric integrity across −60…+250 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.