Switchgear & control cabinet wiring
Compact 300 V PTFE/PFA profile simplifies high-density routing inside control panels, avionics racks, and equipment chassis.
Product
FP/FA 260 °C Controlled-Impedance Pair combines silver-plated copper twisted pairs in low-loss PTFE insulation, ≥ 85% silver-plated copper braid, and a translucent white PFA outer sheath for 260 °C aerospace and downhole telemetry.
Typical values for this cable type, based on IEC 61156 (100 Ω ref.) · ASTM B298 Silver Cu · UL VW-1 — confirmed in the datasheet and quotation for your order.
Application fit
FP/FA 260 °C Controlled-Impedance Pair combines silver-plated copper twisted pairs in low-loss PTFE insulation, ≥ 85% silver-plated copper braid, and a translucent white PFA outer sheath for 260 °C aerospace and downhole telemetry.
Compact 300 V PTFE/PFA profile simplifies high-density routing inside control panels, avionics racks, and equipment chassis.
Stable 300 V PTFE/PFA construction routes cleanly in stationary conduits, raceways, ducts, and equipment bays.
Low-weight, high-temperature 300 V PTFE/PFA construction meets compact avionics racks, flight-control looms, and aerospace harnesses.
Controlled-impedance 300 V construction delivers low-attenuation telemetry across industrial Ethernet, fieldbus, and control racks.
300 V PTFE/PFA construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR300 V PTFE/PFA build lacks anti-torsion tensile reinforcement for motorised drum reeling; select a dedicated reeling cable.
Use RG / RG-D (N)SHTOEU-JConstruction
Representative construction of FP/FA 260°C Impedance Pair: ASTM B298 Class K stranded silver-plated annealed copper, Low-loss extruded PTFE fluoropolymer (100 Ω differential pair), and Off-white 260 °C extruded PFA fluoropolymer outer sheath.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | ASTM B298 Class K stranded silver-plated annealed copperASTM B298 Silver Cu |
| 2 | Dielectric / core insulation | Low-loss extruded PTFE fluoropolymer (100 Ω differential pair)IEC 61156 (100 Ω ref.) |
| 3 | Core assembly & separator | Concentric cabled core assembly with low-friction fleece/polyester separator tapeIEC 61156 (100 Ω ref.) |
| 4 | Metallic EMC screen | Overall ≥ 85% silver-plated copper wire braid shieldEMC ≥ 85% shield |
| 5 | Outer sheath | Off-white 260 °C extruded PFA fluoropolymer outer sheath260 °C Continuous PFA/PTFE |
Colour-coded or numbered flexible conductors assembled concentrically inside protective outer sheath.
Technical data
Sizes
| Pairs · Impedance | Outer Ø ≈ mm | Max. R20 Ω/km | Metal index kg/km | Weight ≈ kg/km | Min. bend R 10×D mm |
|---|---|---|---|---|---|
| 1P×26 AWG · 100 Ω | 3.6 | 150.00 | 14 | 30 | 36 |
| 1P×24 AWG · 100 Ω | 4.2 | 94.20 | 20 | 42 | 42 |
| 1P×22 AWG · 100 Ω | 4.8 | 59.40 | 28 | 56 | 48 |
| 2P×24 AWG · 100 Ω | 6.2 | 94.20 | 38 | 78 | 62 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| High-voltage dielectric spark / withstand test | 1.5 kV AC without breakdown | Every manufactured drum |
| Conductor DC resistance check | Per ASTM B298 Silver Cu at 20 °C | Every reel / drum length |
| Sample tests | ||
| Dimensional, wall thickness & thermal aging | Rated -100 °C to +260 °C continuous | Per production lot |
| Flame, chemical & mechanical qualification | 260 °C Continuous PFA/PTFE · 100 Ω ± 10 Ω Impedance | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.