Contact

TGGT 250 °C UL 5256 / 5257 600 V PTFE-Glass Wire250 °C nickel-plated copper PTFE-tape & PTFE-saturated glass-braid wire

TGGT 250 °C UL 5256 / 5257 layers PTFE fluoropolymer tapes and glass-fiber wrappings over nickel-plated copper under a white PTFE-impregnated fibreglass outer braid rated 600 V and 250 °C for harsh thermal-chemical zones.

Flame-retardant
Oil-resistant
Approved
Order designation
TGGT 250°C UL 5256/5257 Wire 1×12 AWG
Outer Ø
4.0 mm
Max. R20
6.395 Ω/km
Weight
66 kg/km
Min. bend R
32 mm
All sizes (8)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V
Test voltage 2.5 kV AC
Temp. (fixed)
-65°C…+250°C
Flexing: -40 °C to +250 °C
Construction
Mica + Glass
Overlapping PTFE fluoropolymer &
Min. bend radius
8 × OD
High-current flexible routing
Conductor
Nickel-Plated Cu
Per UL AWM Style 5256
Size range
1×18 AWG–1×4 AWG
8 standard configurations

Typical values for this cable type, based on UL AWM Style 5256 · UL AWM Style 5257 · CSA AWM I A/B — confirmed in the datasheet and quotation for your order.

Application fit

Is TGGT 250°C UL 5256/5257 Wire right for your machine?

TGGT 250 °C UL 5256 / 5257 layers PTFE fluoropolymer tapes and glass-fiber wrappings over nickel-plated copper under a white PTFE-impregnated fibreglass outer braid rated 600 V and 250 °C for harsh thermal-chemical zones.

Furnace, kiln & high-temp zone

Suitable

Thermal-rated 600 V PTFE build delivers stable high-current power near furnaces, ovens, kilns, and molten-metal zones.

Fixed installation

Suitable

Durable 600 V PTFE geometry installs cleanly along transformer links, busbar transitions, trays, and industrial bays.

High-temperature boiler & thermal plant

Suitable

Thermal-aged 600 V PTFE insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.

Control cabinet & internal panel wiring

Suitable

Compact flame-retardant 600 V PTFE geometry routes neatly through dense switchgear ducts, control cabinets, and DIN-rail terminals.

Energy chain / drag chain

Not suitable

600 V PTFE construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Immersion & wet locations

Not suitable

600 V PTFE outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesSteelworks, rolling mills & aluminum smeltersIndustrial ovens, ceramic kilns & glassworksCommercial heating elements & cartridge heatersPower plants, boiler rooms & hot switchgear

Construction

Layer by layer

Representative construction of TGGT 250°C UL 5256/5257 Wire: ASTM B355 Class K stranded nickel-plated copper (27% Ni high-temp), Overlapping PTFE fluoropolymer & glass-fiber tape dielectric, and Off-white PTFE-saturated fibreglass outer braid (fluoro/glass).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorASTM B355 Class K stranded nickel-plated copper (27% Ni high-temp)ASTM B355 Nickel Cu
2Mica / PTFE tape dielectricOverlapping PTFE fluoropolymer & glass-fiber tape dielectricUL AWM Style 5256
3Fibreglass outer braidOff-white PTFE-saturated fibreglass outer braid (fluoro/glass)250 °C Continuous TGGT

TGGT 250°C UL 5256/5257 Wire Mica-Glass

Single high-temperature conductor wrapped in overlapping thermal dielectric tape and varnished fibreglass outer braid.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on UL AWM Style 5256 · UL AWM Style 5257 · CSA AWM I A/B. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
600 V
Test voltage
2.5 kV AC
Conductor
Nickel-Plated Cu
Core / dielectric
Overlapping PTFE fluoropolymer &
Impedance / insulation
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-65 °C to +250 °C
Temp. range (flexing)
-40 °C to +250 °C
Peak / short-circuit
+250 °C (short-term)
Min. bending radius
8 × OD

Resistance

Primary performance
250 °C Continuous TGGT
Environment / duty
UL VW-1 Flame
Mechanical / special
Moisture & Oil Sealed Glass
Outer finish
Off-white PTFE-saturated fibreglass outer

Sizes

High-Temp Mica/Glass Wire (AWG)
Conductor
AWG
Outer Ø ≈
mm
Max. R20
Ω/km
Copper index
kg/km
Weight ≈
kg/km
Min. bend R
8×D mm
1×18 AWG2.725.98482022
1×16 AWG3.016.464122824
1×14 AWG3.510.158194328
1×12 AWG4.06.395316632
1×10 AWG4.64.021499937
1×8 AWG5.42.5317815343
1×6 AWG6.41.59012423751
1×4 AWG7.70.99919737162
  • Conductor DC resistance R20 at 20 °C per ASTM B355 Nickel Cu.
  • Minimum bending radius calculated at 8 × nominal outer diameter (OD). Custom terminations available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
High-voltage dielectric withstand test2.5 kV AC without breakdownEvery manufactured length
Continuity & conductor DC resistancePer ASTM B355 Nickel Cu at 20 °CEvery drum / assembly
Sample tests
Tensile, dimensional & pressure checkRated -65 °C to +250 °C continuousPer production lot
Environmental, thermal & mechanical qualification250 °C Continuous TGGT · UL VW-1 FlameType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL AWM Style 5256UL AWM Style 5257CSA AWM I A/BEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TGGT 250°C UL 5256/5257 Wire 600 V TEBAOFLEX.COM [UL AWM Style 5256] [Size] [Metre mark]
Delivery form
Custom assemblies, coils or export drums
Standard lengths
Cut-to-length · 100 m · 500 m · 1,000 m
MOQ
1 assembly / 50 m (stock) · 300 m (custom)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-23
Updated
2026-11-23

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes TGGT 250°C UL 5256/5257 Wire suited for demanding 600 V installations?
TGGT 250°C UL 5256/5257 Wire combines ASTM B355 Class K stranded nickel-plated copper (27% Ni high-temp) with Overlapping PTFE fluoropolymer & glass-fiber tape dielectric and Off-white PTFE-saturated fibreglass outer braid (fluoro/glass). PTFE-saturated glass braid resists moisture ingress, chemicals, and sharp-edge abrasion at 250 °C.
What minimum bending radius should be respected for TGGT 250°C UL 5256/5257 Wire?
Maintain a minimum bending radius of 8 × OD across -40 °C to +250 °C flexing temperatures to ensure long mechanical and dielectric service life.
Can TGGT 250°C UL 5256/5257 Wire be delivered pre-terminated with custom lugs, water fittings, or subsea connectors?
Yes. TEBAOFLEX supplies TGGT 250°C UL 5256/5257 Wire either in bulk lengths or factory-assembled with copper lugs, water-cooled swivel fittings, or molded subsea wet-mate connectors.
What quality tests and certificates accompany every shipment of TGGT 250°C UL 5256/5257 Wire?
TGGT 250°C UL 5256/5257 Wire conforms to UL AWM Style 5256, UL AWM Style 5257, CSA AWM I A/B (250 °C Continuous TGGT) and ships with an EN 10204 3.1 routine factory test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for TGGT 250°C UL 5256/5257 Wire

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

TGGT 250 °C UL 5256 / 5257 600 V PTFE-Glass Wire

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote